JPM-ANO-2-JPM-NRC-CCP01 PAGE 1 OF 5 JOB PERFORMANCE MEASURE UNIT: 2 REV #: 6 DATE:
SYSTEM/DUTY AREA: Pressurizer Level Control System TASK: Shifting Lead Charging Pump JTA#: 20045510401 KA VALUE RO: 3.5 SRO: 3.7 KA
REFERENCE:
011 A2.04 APPROVED FOR ADMINISTRATION TO: RO: X SRO: X TASK LOCATION: INSIDE CR: X OUTSIDE CR: BOTH:
SUGGESTED TESTING ENVIRONMENT AND METHOD (PERFORM OR SIMULATE):
PLANT SITE: SIMULATOR: Perform LAB:
POSITION EVALUATED: RO: SRO:
ACTUAL TESTING ENVIRONMENT: SIMULATOR: X PLANT SITE: LAB:
TESTING METHOD: SIMULATE: PERFORM: X APPROXIMATE COMPLETION TIME IN MINUTES: 5 Minutes REFERENCE(S): OP 2104.002 Rev 038-01-0 EXAMINEE'S NAME: SSN: - -
EVALUATOR'S NAME:
THE EXAMINEE'S PERFORMANCE WAS EVALUATED AGAINST THE STANDARDS CONTAINED IN THIS JPM AND IS DETERMINED TO BE:
SATISFACTORY: UNSATISFACTORY:
PERFORMANCE CHECKLIST COMMENTS:
Start Time Stop Time Total Time SIGNED__________________________________ DATE: _____________________
SIGNATURE INDICATES THIS JPM HAS BEEN COMPARED TO ITS APPLICABLE PROCEDURE BY A QUALIFIED INDIVIDUAL (NOT THE EXAMINEE) AND IS CURRENT WITH THAT REVISION.
THE EXAMINER SHALL REVIEW THE FOLLOWING WITH THE EXAMINEE:
JPM-ANO-2-JPM-NRC-CCP01 PAGE 2 OF 5 JOB PERFORMANCE MEASURE The examiner shall review the "Briefing Checklist - System Walkthrough" portion of OP 1064.023 Attachment 6 with the examinee.
JPM INITIAL TASK CONDITIONS: WCO has requested Charging Pump 2P36B be stopped to perform oil level check. THIS IS AN ALTERNATE SUCCESS PATH JPM.
TASK STANDARD: Shift lead charging pump.
TASK PERFORMANCE AIDS: OP 2104.002 SIMULATOR SETUP: Select "B" as lead charging pump and trigger 2P36C Plunger Break CVC2P36CBRK. 2P36C aligned to green bus.
JPM-ANO-2-JPM-NRC-CCP01 PAGE 3 OF 5 JOB PERFORMANCE MEASURE INITIATING CUE:
The SS/CRS directs, "Shift lead charging pump to 2P36C using OP 2104.002 Section 8.1. Seal water pump has been running for 15 minutes."
CRITICAL ELEMENTS (C): 2 PERFORMANCE CHECKLIST STANDARDS (Circle One) 1.
Place selected pump handswitch to START.
On 2C09, placed 2HS-4853-2 to START. Observed red light ON and green light OFF.
N/A SAT UNSAT (C) 2.
Check Charging Flow goes up ~44 gpm.
On 2C09, checked Charging Flow (2FIS-4863) and reports flow indicates 60 gpm.
N/A SAT UNSAT 3.
Did not get expected response, therefore secure 2P36C.
Placed 2HS-4853-2 to AUTO or STOP. Observed red light OFF and green light ON.
N/A SAT UNSAT EXAMINEERS CUE:
Act as CRS and direct examinee to select 2P36A as lead charging pump.
4.
Place selected pump handswitch to START.
On 2C09, placed 2HS-4832-1 to START. Observed red light ON and green light OFF.
N/A SAT UNSAT 5.
Check Charging Flow goes up ~44 gpm.
On 2C09, checks Charging Flow (2FIS-4863) flow indicates ~88 gpm.
N/A SAT UNSAT 6.
Place Charging Pump Select Switch (2HS-4868) to selected lead pump.
On 2C09, placed Charging Pump Select handswitch (2HS-4868) to PMP B&C position.
N/A SAT UNSAT 7.
Verify previous lead pump stops.
Checked 2P36B stopped. Observed red light OFF and green light ON.
N/A SAT UNSAT 8.
Check Charging Flow lowers
~44 gpm.
On 2C09, checks Charging Flow (2FIS-4863) flow indicates ~44 gpm.
N/A SAT UNSAT 9.
Place selected pump handswitch to AUTO.
On 2C09, placed 2HS-4832-1 to AUTO.
N/A SAT UNSAT END
JPM-ANO-2-JPM-NRC-CCP01 PAGE 4 OF 5 JOB PERFORMANCE MEASURE QUESTION ANSWER
JPM-ANO-2-JPM-NRC-CCP01 PAGE 5 OF 5 JOB PERFORMANCE MEASURE EXAMINEES COPY JPM INITIAL TASK CONDITIONS:
WCO has requested Charging Pump 2P36B be stopped to perform oil level checks.
INITIATING CUE:
The SS/CRS directs, "Shift lead charging pump to 2P36C using OP 2104.002 Section 8.1. Seal water pump has been running for 15 minutes."