JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 1 OF 6 ADMIN JOB PERFORMANCE MEASURE UNIT:

2 REV #:

000 DATE:

SYSTEM/DUTY AREA:

Equipment Control TASK:

Evaluate Containment Atmospheric Conditions (using computer - normal operations).

JTA#:

21035010201 KA VALUE RO:

3.0 SRO:

3.4 KA

REFERENCE:

2.2.12 APPROVED FOR ADMINISTRATION TO:

RO:

X SRO:

X TASK LOCATION:

INSIDE CR:

X OUTSIDE CR:

BOTH:

SUGGESTED TESTING ENVIRONMENT AND METHOD (PERFORM OR SIMULATE):

PLANT SITE:

Simulate SIMULATOR:

Perform LAB:

POSITION EVALUATED:

RO:

SRO:

ACTUAL TESTING ENVIRONMENT:

SIMULATOR:

PLANT SITE:

LAB:

TESTING METHOD:

SIMULATE:

PERFORM:

APPROXIMATE COMPLETION TIME IN MINUTES:

10 Minutes REFERENCE(S):

OP 2104.033 Rev 039-01-0 EXAMINEE'S NAME:

SSN:

EVALUATOR'S NAME:

THE EXAMINEE'S PERFORMANCE WAS EVALUATED AGAINST THE STANDARDS CONTAINED IN THIS JPM AND IS DETERMINED TO BE:

SATISFACTORY:

UNSATISFACTORY:

PERFORMANCE CHECKLIST COMMENTS:

Start Time Stop Time Total Time SIGNED:

DATE:

SIGNATURE INDICATES THIS JPM HAS BEEN COMPARED TO ITS APPLICABLE PROCEDURE BY A QUALIFIED INDIVIDUAL (NOT THE EXAMINEE) AND IS CURRENT WITH THAT REVISION.

JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 2 OF 6 ADMIN JOB PERFORMANCE MEASURE THE EXAMINER SHALL REVIEW THE FOLLOWING WITH THE EXAMINEE:

The examiner shall review the "Briefing Checklist - System Walkthrough" portion of OP 1064.023 Attachment 6 with the examinee.

JPM INITIAL TASK CONDITIONS:

100% steady state power operations. The PMS computer is available.

TASK STANDARD:

Containment atmospheric conditions have been evaluated in accordance with Technical Specifications.

TASK PERFORMANCE AIDS:

OP 2104.033, Supplement 4 ; calculator EXAMINER'S NOTE:

JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 3 OF 6 ADMIN JOB PERFORMANCE MEASURE INITIATING CUE:

The SS/CRS directs, "Perform an evaluation of containment atmospheric conditions using OP 2104.033 Supplement 4."

CRITICAL ELEMENTS (C): 3, 5, 6, 7 PERFORMANCE CHECKLIST STANDARDS (Circle One) 1.

Verify computer points available.

POSITIVE CUE:

All required computer points available.

On SPDS terminal or on the PMS computer, verified the following computer points available:

- T5605-5

- T5606-6 and at least three of the following:

- P5601-1 through

- P5601-4 N/A SAT UNSAT 2.

Record containment temperature.

POSITIVE CUE:

Containment temperatures are:

T5605-5 116.9F T5606-6 115.7F On SPDS terminal or on the PMS computer, displayed following containment temperature points:

T5605-5 T5606-6 Recorded containment temperature readings in OP 2104.033 Supplement 4 Step 2.1.

N/A SAT UNSAT (C) 3.

Calculate average containment temperature.

Used formula provided in OP 2104.033 Supplement 4 and readings from SPDS or PMS computer to calculate average containment temperature.

Recorded average containment temperature on OP 2104.033 Supplement 4 Step 2.1.

N/A SAT UNSAT 4.

Record containment pressure.

POSITIVE CUE:

Containment pressures are:

P5601-1 14.1 psia P5602-2 14.2 psia P5603-3 14.2 psia P5604-4 14.1 psia On SPDS terminal 2C69 or on the PMS computer, displayed at least three of the following containment pressure points:

P5601-1 P5603-3 P5602-2 P5604-4 Recorded containment pressure readings in OP 2104.033 Supplement 4 Step 2.2.

N/A SAT UNSAT

JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 4 OF 6 ADMIN JOB PERFORMANCE MEASURE PERFORMANCE CHECKLIST STANDARDS (Circle One)

(C) 5.

Calculate average containment pressure.

Used table provided in OP 2104.033 Supplement 4 Step 2.2 and readings from SPDS or from PMS computer to calculate average containment pressure.

Recorded average containment pressure on OP 2104.033 Supplement 4 Step 2.2.

N/A SAT UNSAT (C) 6.

Plot average containment pressure vs average containment temperature.

Plotted calculated parameters on OP 2104.033 Supplement 4, Figure 1.

N/A SAT UNSAT (C) 7.

Compare containment Atmospheric parameters to Technical Specification requirements.

Used containment pressure-temperature point plotted on Figure 4-1 to determine if containment atmospheric conditions are within the region of acceptable operations.

Completed OP 2104.033 Supplement 4 Section 3.0 to indicate Technical Specification 3.6.1.4 compliance.

N/A SAT UNSAT END

JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 5 OF 6 ADMIN JOB PERFORMANCE MEASURE QUESTION 1:

ANSWER:

JPM-ANO-2-JPM-NRC-CNTMT01 PAGE 6 OF 6 ADMIN JOB PERFORMANCE MEASURE EXAMINEES COPY JPM INITIAL TASK CONDITIONS: 100% steady state power operations. The PMS computer is available.

INITIATING CUE:

The SS/CRS directs, "Perform an evaluation of containment atmospheric conditions using OP 2104.033 Supplement 4."