Letter Sequence RAI |
---|
|
|
MONTHYEARML0720702572007-06-29029 June 2007 Technical Specification Change Request No. 337 - Reactor Building Emergency Sump Ph Control System Buffer Change Project stage: Other ML0726102912007-09-20020 September 2007 Electronic Transmission, Draft Request for Additional Information Regarding Reactor Building Sump Ph Control System Buffer Change Project stage: Draft RAI ML0726705392007-09-25025 September 2007 Electronic Transmission, Draft Request for Additional Information Regarding Reactor Building Sump Ph Control System Buffer Change Project stage: Draft RAI ML0726705492007-10-0404 October 2007 Request for Additional Information Regarding Proposed Ph Control System Buffer Change Project stage: RAI ML0729806992007-10-19019 October 2007 Response to Request for Additional Information - Technical Specification Change Request No. 337: Reactor Building Emergency Sump Ph Control System Buffer Change Project stage: Response to RAI ML0730601372007-11-0505 November 2007 Electronic Transmission, Draft Request for Additional Information Regarding Reactor Building Sump Ph Control System Buffer Change Project stage: Draft RAI ML0733104162007-11-27027 November 2007 Request for Additional Information Regarding Proposed Reactor Building Emergency Sump System Buffer Change Project stage: RAI ML0733803942007-11-29029 November 2007 Response to Request for Additional Information - Technical Specification Change Request No. 337: Reactor Building Emergency Sump Ph Control System Buffer Change Project stage: Response to RAI 2007-11-29
[Table View] |
|
---|
Category:Letter
MONTHYEARRS-24-097, Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 12024-10-23023 October 2024 Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 1 ML24256A0422024-10-0404 October 2024 Updated Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24242A3032024-09-0909 September 2024 Letter - Three Mile Island Station, Unit 2, Issuance of Amendment No. 68, Historic and Cultural Resources IR 05000320/20240012024-08-28028 August 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2024001 and 05000320/2024002 ML24240A2222024-08-27027 August 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24220A2742024-08-15015 August 2024 Request for Additional Information Clarification Call Regarding Three Mile Island Station, Unit 2, Amended Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24135A3292024-08-0909 August 2024 Amendment No 68, Historic and Cultural Resources Cover Letter IR 07200077/20240012024-06-18018 June 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 07200077/2024001 ML24157A3672024-06-13013 June 2024 Updated Post-Shutdown Decommissioning Activities Report Request for Additional Information Transmittal Letter ML24135A1972024-06-13013 June 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0091 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24120A3242024-05-24024 May 2024 TMI-2 Email to Fws RS-24-055, 2023 Corporate Regulatory Commitment Change Summary Report2024-05-17017 May 2024 2023 Corporate Regulatory Commitment Change Summary Report ML24121A2472024-04-29029 April 2024 And Three Mile Island, Unit 2 - 2023 Occupational Radiation Exposure Annual Report ML24120A2552024-04-29029 April 2024 Annual Radiological Environmental Operating Report ML24113A0212024-04-18018 April 2024 (TMI-2), Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-24-002, Constellation Energy Generation, LLC - Annual Property Insurance Status Report2024-04-0101 April 2024 Constellation Energy Generation, LLC - Annual Property Insurance Status Report ML24092A0012024-03-28028 March 2024 (TMI-2), Decommissioning Trust Fund Annual Report ML24065A0042024-03-28028 March 2024 Submittal of 2023 Aircraft Movement Data Annual Report ML24088A0122024-03-28028 March 2024 Notification of Amended Post-Shutdown Decommissioning Activities Report (PSDAR) in Accordance with 10 CFR 50.82(a)(7), Revision 6 ML24085A2152024-03-25025 March 2024 (TMI-2) - Annual Notification of Property Insurance Coverage RS-24-023, Report on Status of Decommissioning Funding.2024-03-22022 March 2024 Report on Status of Decommissioning Funding. ML24052A0602024-03-20020 March 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0061 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24074A3922024-03-14014 March 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML24075A0062024-03-14014 March 2024 List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24073A2312024-03-13013 March 2024 And Three Mile Island Nuclear Station, Unit 2 - Management Change ML24044A0092024-02-12012 February 2024 License Amendment Request – Three Mile Island, Unit 2, Historic and Cultural Resources Review, Response to Request for Additional Information IR 05000320/20230042024-02-0707 February 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023004 ML24038A0222024-02-0505 February 2024 Achp Letter on Section 106 Programmatic Agreement Participation IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 ML23342A1242024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23325A1092024-01-0505 January 2024 Review of the Management Plan for Three Mile Island Station, Unit No. 2, Debris Material ML23354A2062023-12-20020 December 2023 (TMI-2), Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23354A2112023-12-20020 December 2023 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 ML23243A9082023-08-29029 August 2023 SHPO Letter to TMI-2 Regarding Section 106 Activities IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 ML23216A1782023-08-14014 August 2023 Consultation Letter to Steve Letavic for TMI-2 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 ML23216A1772023-08-14014 August 2023 Consultation Letter to Rebecca Countess for TMI-2 ML23216A1732023-08-14014 August 2023 Consultation Letter to Christine Turner for TMI-2 ML23216A1742023-08-14014 August 2023 Consultation Letter to David Morrison for TMI-2 ML23216A1752023-08-14014 August 2023 Consultation Letter to Joanna Cain for TMI-2 ML23221A1402023-08-0808 August 2023 (TMI-2), Response to Requests for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML23213A2342023-08-0101 August 2023 Submittal of Defueled Safety Analysis Report and Decommissioning Quality Assurance Plan ML23200A1882023-07-31031 July 2023 TMI-2 Correction Letter Amendment 67 ML23209A7632023-07-28028 July 2023 Letter from PA SHPO to TMI-2 Solutions on Cultural and Historic Impacts of Decommissioning ML23192A8272023-07-10010 July 2023 TMI-2 Solutions, LLC - Response to SHPO Request for Additional Information for Er Project 2021PR03278.006, TMI-2 Decommissioning Project ML23167A4642023-07-0505 July 2023 Letter - TMI-2- Exemption 10 CFR Part 20 Append G Issuance 2024-09-09
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24220A2742024-08-15015 August 2024 Request for Additional Information Clarification Call Regarding Three Mile Island Station, Unit 2, Amended Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24157A3672024-06-13013 June 2024 Updated Post-Shutdown Decommissioning Activities Report Request for Additional Information Transmittal Letter ML24011A2352024-01-11011 January 2024 Eco Request for Additional Information for 2023 License Amendment Request 1-11-24 ML23187A0202023-06-29029 June 2023 TMI Unit 2 – RAI Related to the Amended Post-Shutdown Decommissioning Activities Report ML23187A0332023-06-29029 June 2023 TMI Unit 2, PSDAR Rev. 5 RAIs ML23082A3432023-03-31031 March 2023 Enclosure - RAI - Three Mile Island, Unit 2 - Acceptance Review and Request for Additional Information for the Historic and Cultural Resources License Amendment Request - EPID: 2023-LLA-0026 ML22357A0142022-12-22022 December 2022 NRC Request for Additional Information Related to the TMI-2 Pdms Transition License Amendment Request ML22210A0882022-07-29029 July 2022 Enclosure - Three Mile Island, Unit No. 2 - Request for Additional Information for Requested Licensing Action Regarding Decommissioning Technical Specifications ML22143A8902022-05-23023 May 2022 Request for Additional information- TMI-1 ISFSI Only Physical Security License Amendment Request ML22125A0122022-04-28028 April 2022 Clarification RAI Partial Response Email from C Smith to a Snyder ML22110A0202022-04-19019 April 2022 Unit 1 Request for Additional Information ML22038A9362022-02-0707 February 2022 TMI2 Accident Analyses Questions ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML20164A0902020-06-10010 June 2020 Request for Additional Information Related to TMI-1 License Amendment Request to Delete Permanently Defueled Technical Specification 3/4.1.4 (L-2019-LLA-0250) ML19319B2082019-11-15015 November 2019 NRR E-mail Capture - Request for Additional Information Related to TMI-1 Request for Exemption from Portions of 10 CFR 50.47 and Part 50 Appendix E (L-2019-LLA-0216) ML19179A0612019-07-19019 July 2019 Three Mile Point 1 - Supplemental Information Needed to Proposed Alternative to Use ASME Code Case N-879 ML18220A7832018-08-0707 August 2018 NRR E-mail Capture - Request for Additional Information Related to TMI Fall 2017 Steam Generator Tube Inspection Report ML18212A2712018-07-31031 July 2018 NRR E-mail Capture - Request for Additional Information Related to Amendment Regarding Decommissioning ERO Staffing Changes ML17285B1962017-10-27027 October 2017 Request for Additional Information Regarding Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools. ML17062A4912017-03-0303 March 2017 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Fleet Alternative to RPV Threads in Flange Examination (CAC Nos. MF8712-MF8729) ML16356A4802016-12-21021 December 2016 NRR E-mail Capture - RAIs on TMI License Amendment Request for Approval of Changes to the Three Mile Island Nuclear Station Emergency Plan Related to Staffing ML16337A0072016-12-0101 December 2016 NRR E-mail Capture - Draft RAIs Three Mile Island Nuclear Station, Units 1 and 2, License Amendment Request for Approval of Changes to the Three Mile Island Nuclear Station Emergency Plan Related to Staffing ML16287A4042016-10-11011 October 2016 Notification of Conduct of a Triennial Fire Protection Baseline Inspection ML15230A5332015-08-18018 August 2015 Draft Request for Additional Information ML15020A7372015-03-0808 March 2015 Request for Additional Information Regarding Related to December 22, 2014, Report Submitted Pursuant to 10 CFR 50.46 ML14307A1172014-11-14014 November 2014 Request for Additional Information Regarding Relief Request RR-14-01 Concerning Alternative Root Mean Square Depth Sizing Requirements ML14240A4122014-09-0404 September 2014 Request for Additional Information Regarding License Amendment Request to Eliminate Certain Technical Specification Reporting Requirements (Tac MF0628) ML14134A3222014-05-22022 May 2014 Request for Additional Information Regarding Review of Three Mile Island Nuclear Station Unit 1 Cycle 20 Core Operating Limits Report ML14134A1722014-05-14014 May 2014 Draft RAIs in Support of NRC Staff Review of TMI Cycle 20 COLR ML14052A2592014-02-27027 February 2014 Request for Additional Information Regarding Proposed License Amendment Request to Revise Technical Specification Reporting Requirements ML14030A5832014-01-29029 January 2014 Draft Request for Additional Information Proposed Revision to Technical Specifications Reporting Requirements Exelon Generation Company, LLC Three Mile Island Nuclear Station, Unit 1 ML13266A2852013-10-21021 October 2013 Request for Additional Information on Three Mile Island Nuclear Station Unit 2 - post-shutdown Decommissioning Activities Report ML13276A6492013-10-0303 October 2013 Notification of Conduct of a Triennial Fire Protection Baseline Inspection ML13269A1792013-09-25025 September 2013 Draft Request for Additional Information ML13253A2252013-09-10010 September 2013 Draft Request for Additional Information ML13249A2072013-09-0505 September 2013 Draft Request for Additional Information ML13193A1752013-07-22022 July 2013 Request for Additional Information Regarding Revision to Pressure and Temperature Limit Curves and Exemption Request for Initial Reference Temperature Values ML13196A3382013-07-15015 July 2013 2013 Decommissioning Fund Report RAI ML13193A1452013-07-12012 July 2013 Electronic Transmission, Draft Request for Additional Information Regarding Proposed Revision to Pressure and Temperature Limit Curves and Exemption Request for Initial Reference Temperature Values (TAC Nos. MF0425 & MF0426) ML13176A4702013-06-26026 June 2013 Request for Additional Information Regarding Overall Integrated Plan in Response to Order Number EA-12-051, Reliable Spent Fuel Pool Instrumentation ML13177A3902013-06-26026 June 2013 Electronic Transmission, Draft Request for Additional Information Regarding Overall Integrated Plan in Response to Order Number EA-12-051, Reliable Spent Fuel Pool Instrumentation ML13066A2442013-03-19019 March 2013 Request for Additional Information Regarding Fifth Inservice Test Interval Relief Request PR-01 Nuclear Services Closed Cooling Water Flow Measurement ML13066A1262013-03-0707 March 2013 Electronic Transmission, Draft Request for Additional Information Regarding Fifth Inservice Test Interval Relief Request PR-01 Nuclear Services Closed Cooling Water Flow Measurement ML13044A3212013-03-0505 March 2013 Request for Additional Information Regarding 30-Day Report for Emergency Core Cooling System Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML13045A6432013-02-25025 February 2013 Request for Additional Information Regarding Relief Request VR-01, Associated with the Fifth Inservice Testing Interval ML13051A3852013-02-25025 February 2013 Request for Additional Information Regarding End-of-Interval Relief Request RR-12-01, Pressure Nozzle-to-Head Weld Exams ML13050A6362013-02-20020 February 2013 Draft RAI Memo ML13044A3122013-02-13013 February 2013 Electronic Transmission, Draft Request for Additional Information Regarding 30-Day Report for Emergency Core Cooling System Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML13044A6652013-02-13013 February 2013 Electronic Transmission, Draft Request for Additional Information Regarding Relief Request VR-01, Associated with the Fifth Inservice Testing Interval 2024-08-15
[Table view] |
Text
October 4, 2007 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED REACTOR BUILDING EMERGENCY SUMP SYSTEM BUFFER CHANGE (TAC NO. MD5963)
Dear Mr. Crane:
By letter dated June 29, 2007 (Agencywide Documents Access and Management System Accession Number ML072070257), AmerGen Energy Company, LLC, submitted an amendment request for the Three Mile Island Nuclear Station, Unit 1. The proposed amendment would revise the technical specifications to accommodate a change in the reactor building emergency sump pH control system buffer from sodium hydroxide to trisodium phosphate dodecahydrate.
The NRC staff has been reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information. The questions were sent via electronic transmission on September 18 and September 24, 2007, to Mr. David Distel of your staff. The draft questions were sent to ensure that the questions were understandable, the regulatory basis for the questions was clear, and to determine if the information was previously docketed. The majority of these questions were discussed with your staff in a teleconference on September 20, 2007, where clarification was provided in some areas and one of the draft questions was deleted. It was agreed that your response would be provided within 30 days of the date of this letter.
Please contact me at 301-415-2833, if you have any questions.
Sincerely,
/RA /
Peter J. Bamford, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-289
Enclosure:
As stated cc w/encl: See next page
Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED REACTOR BUILDING EMERGENCY SUMP SYSTEM BUFFER CHANGE (TAC NO. MD5963)
Dear Mr. Crane:
By letter dated June 29, 2007 (Agencywide Documents Access and Management System Accession Number ML072070257), AmerGen Energy Company, LLC, submitted an amendment request for the Three Mile Island Nuclear Station, Unit 1. The proposed amendment would revise the technical specifications to accommodate a change in the reactor building emergency sump pH control system buffer from sodium hydroxide to trisodium phosphate dodecahydrate.
The NRC staff has been reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information. The questions were sent via electronic transmission on September 18 and September 24, 2007, to Mr. David Distel of your staff. The draft questions were sent to ensure that the questions were understandable, the regulatory basis for the questions was clear, and to determine if the information was previously docketed. The majority of these questions were discussed with your staff in a teleconference on September 20, 2007, where clarification was provided in some areas and one of the draft questions was deleted. It was agreed that your response would be provided within 30 days of the date of this letter.
Please contact me at 301-415-2833, if you have any questions.
Sincerely,
/RA/
Peter J. Bamford, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-289
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC RidsOgcRp LPLI-2 R/F RidsAcrsAcnwMailCenter RidsNrrPMPBamford RidsNrrLACSola RidsRgn1MailCenter RidsNrrDorlDpr RidsNrrDorlLpl1-2 RidsNrrLAABaxter MYoder, NRR KParczewski, NRR NPatel, NRR ADAMS Accession Number: ML072670549
- by memo OFFICE LPL1-2/PM LPL1-2/LA LPL2-2/LA EEEB/BC* CSGB/BC* LPL1-2/BC NAME PBamford ABaxter CSola GWilson AHiser HChernoff DATE 9/25/07 10/1/07 9/28/07 09/20/2007 09/17/2007 10/4/07 OFFICIAL RECORD COPY
Three Mile Island Nuclear Station, Unit 1 cc:
Site Vice President - Three Mile Island Nuclear Director Station, Unit 1 Bureau of Radiation Protection AmerGen Energy Company, LLC Pennsylvania Department of P. O. Box 480 Environmental Protection Middletown, PA 17057 Rachel Carson State Office Building P.O. Box 8469 Vice President - Operations, Mid-Atlantic Harrisburg, PA 17105-8469 AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Plant Manager - Three Mile Island Nuclear Kennett Square, PA 19348 Station, Unit 1 AmerGen Energy Company, LLC Vice President - Licensing and Regulatory P. O. Box 480 Affairs Middletown, PA 17057 AmerGen Energy Company, LLC 4300 Winfield Road Regulatory Assurance Manager - Three Mile Warrenville, IL 60555 Island Nuclear Station, Unit 1 AmerGen Energy Company, LLC Regional Administrator P.O. Box 480 Region I Middletown, PA 17057 U.S. Nuclear Regulatory Commission 475 Allendale Road Ronald Bellamy, Region I King of Prussia, PA 19406 U.S. Nuclear Regulatory Commission 475 Allendale Road Chairman King of Prussia, PA 19406 Board of County Commissioners of Dauphin County Michael A. Schoppman Dauphin County Courthouse Framatome ANP Harrisburg, PA 17120 Suite 705 1911 North Ft. Myer Drive Chairman Rosslyn, VA 22209 Board of Supervisors of Londonderry Township Dr. Judith Johnsrud R.D. #1, Geyers Church Road National Energy Committee Middletown, PA 17057 Sierra Club 433 Orlando Avenue Senior Resident Inspector (TMI-1) State College, PA 16803 U.S. Nuclear Regulatory Commission P.O. Box 219 Eric Epstein Middletown, PA 17057 TMI Alert 4100 Hillsdale Road Director - Licensing and Regulatory Affairs Harrisburg, PA 17112 AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Correspondence Control Desk Kennett Square, PA 19348 AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348
Three Mile Island Nuclear Station, Unit 1 cc:
Manager Licensing - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Assistant General Counsel AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348
REQUEST FOR ADDITIONAL INFORMATION REGARDING REACTOR BUILDING EMERGENCY SUMP SYSTEM BUFFER CHANGE THREE MILE ISLAND NUCLEAR STATION, UNIT 1 TAC NO. MD5963 DOCKET NO. 50-289 By letter dated June 29, 2007, (Agencywide Documents Access and Management System Accession No. ML072070257), AmerGen Energy Company, LLC, the licensee, submitted a license amendment request pertaining to the replacement of the containment sump buffer at Three Mile Island Nuclear Station, Unit 1 (TMI-1).
The Nuclear Regulatory Commission (NRC) Staff has been reviewing the submittal and has determined that additional information is needed to complete its review.
- 1. In Section 7.1, page 15 of Attachment 2, the licensee listed eight chemicals which will exist in the sump water after a loss of coolant accident (LOCA). In its analysis, the licensee assumed that each of them will dissociate or speciate into positive or negative ionic species. By balancing the resulting positive and negative charges, to obtain neutrality of the solution, the licensee could determine the amount of trisodium phosphate (TSP) required for obtaining a given value of pH. Provide a list of the ionic species.
- 2. Describe the procedure for determining speciation of boron and TSP.
- 3. Explain the statement in Section 2.6 on page 5 of Attachment 2 that boron content will not be exceeded provided the power rate does not increase (2568 MWt) and the cycle duration (2 years) does not increase.
- 4. In Section 6, on page 13 of Attachment 2, it is stated that water and boric acid in the sump is determined from a mass balance with two bounding conditions for water and boric acid.
What are they and how were they determined?
- 5. According to Regulatory Guide 1.183, if the sump pH is controlled at the minimum values of 7, the molecular iodine is prevented from formation and release to the containment.
However, during the engineered safety feature recirculation phase, a higher pH is assumed to support iodine flashing fractions at 5 percent for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and 2 percent for the following 29 days. In the submittal the licensee specified the required pH
7.3. Discuss
(1) the methodology for determining this pH value and (2) was the sump water pH buffered at this pH?
Enclosure
- 6. Proposed insert C to technical specification (TS) page 4-2b describes the need to perform periodic solubility tests on the TSP to ensure adequate dissolution time. However, insert D to the proposed TS surveillance requirements, TS page 4-10c, does not include solubility as one of the verifications performed on the TSP. Describe this apparent discrepancy between the TS bases and the TS surveillance requirement.
- 7. When verifying the TSP buffering capability, solubility, and total mass, how is the sample obtained? How does the sampling account for the potential that the TSP on the interior of the basket may exhibit different properties (hydration, density, etc.) than samples taken from the basket periphery? Discuss the potential impact that variations in material properties within each basket may have on surveillance tests to determine buffer capability, solubility, and total mass of TSP available.
- 8. Proposed insert C to TS page 4-2b describes the need to periodically determine the mass of TSP because leaking valves and components may dissolve some of the TSP from the baskets. If a leaking valve or component were to result in a portion of the TSP being dissolved, how would the dissolved TSP be accounted for when adding additional TSP to the basket. If there is no mechanism for removing the dissolved TSP then addition of more TSP may result in a total mass that exceeds the TS limits. Discuss how the loss of TSP through operational dissolution is accounted for when determining the total mass of TSP.
- 9. TMI-1 is proposing to switch to TSP as a buffering chemical. Testing indicates that TSP in the presence of dissolved calcium can result in rapid precipitation of calcium phosphate, which can create significant head loss across a sump strainer covered with a debris bed.
Provide a list of all potential sources and amounts of calcium within the TMI-1 containment and provide the calculated dissolved calcium concentration in a post-LOCA pool. Provide the relative chemical precipitate loading predicted by the WCAP 16530-NP, [Evaluation of Post-Accident Chemical Effects in Containment Sump Fluids to Support GSI-191], model for TMI-1 with TSP and at the maximum projected pH value (8) for the pool.
- 10. In Section 4.5 of Enclosure 1 to the proposed license amendment request, it is stated that the evaluation was based on utilizing and analyzing available industry and technical research data. The evaluation concluded that all environmentally qualified equipment located inside the Reactor Building (RB) are qualified for the revised RB spray chemical conditions resulting from the proposed change. Please provide details of the methodology, assumptions, regulatory provisions applied and analysis to support the above conclusion.
- 11. Please confirm that the temperature profile inside the RB remains unchanged due to the proposed design change.