05000397/FIN-2017002-03
From kanterella
Revision as of 14:04, 30 September 2017 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Finding | |
---|---|
Title | Inadequate Corrective Actions Causes Failure of HPCS Room Normal Supply Fan |
Description | Green . The inspectors reviewed a self -revealed, non- cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for failure to promptly identify and correct a condition adverse to quality. Specifically, since 2012, the licensee failed t o implement prompt corrective actions to correct an adverse condition related to the use of a contactor coil for a motor starter in the high pressure core spray room normal supply fan. As an immediate corrective action, the licensee replaced the contactor for the high pressure core spray room normal supply fan. The licensee entered this issue into the corrective action program as Action Request 360595. The failure to correct an adverse condition related to the use of a contactor coil for a motor starter in the HPCS room normal supply fan, though the licensee had an opportunity and plan to do so, was a performance deficiency. The performance deficiency was more than minor, and therefore a finding, because it affected the design control attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensees failure to correct the use of a contactor coil for a motor starter in the high pressure core spray room normal supply fan resulted in an inoperable fan, high pressure core spray bus 4160 VAC switchgear, and high pressure core spray pump during the January 25, 2017, event when smoke was observed from the motor control center. The inspectors performed the initial significance determination using NRC Inspection Manual Chapter 0609, Appendix A, Exhibit 2, Mitigating Systems Screening Questions. The inspectors determined that the finding was of very low safety significance (Green) because: (1) the finding was not a deficiency affecting the design or qualification of a mitigating system; (2) the finding did not represent a loss of system and/or function; (3) the finding did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time; and (4) the finding does not represent an actual loss of function of one or more nontechnical specification trains of equipment designated as high safety -significant in accordance with the licensees maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The inspectors determined that this finding did not have a cross -cutting aspect as the decision to not replace the contactor occ urred in 2014 and was not reflective of current performance. |
Site: | Columbia |
---|---|
Report | IR 05000397/2017002 Section 4OA2 |
Date counted | Jun 30, 2017 (2017Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | G Kolcum R Alexander D Bradley L Brandt L Carson J Drake S Money J O 'Donnell M Hair |
Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion XVI Technical Specification |
INPO aspect | |
' | |
Finding - Columbia - IR 05000397/2017002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Columbia) @ 2017Q2
Self-Identified List (Columbia)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||