| Title | Failure to Conduct Adequate Surveys of a Solid Radwaste Shipment |
| Description | Green. The team reviewed three examples of a self-revealed, non-cited violation of 10 CFR 20.1501 associated with the failure to conduct adequate surveys of the solid radwaste contents of a shipment that was packaged and transported for ultimate disposal. As a result of the inadequate surveys, the radwaste in shipment No. 16-40 was packaged in the incorrect type of shipping cask, the radwaste manifest and shipping paperwork contained numerous errors, and the waste was not correctly classified in accordance with 10 CFR Part 61. This issue was entered into the corrective action program as Action Request 357593. The failure to conduct adequate surveys of the solid radwaste contents in a shipment that was packaged and transferred for ultimate disposal was a performance deficiency. The team determined that the performance deficiency was more than minor, and therefore a finding, because it was associated with the program and process aspect of the Public Radiation Safety Cornerstone and adversely affected the cornerstone objective to ensure adequate protection of public health and safety from exposure to radioactive materials released in the public domain. Specifically, as a result of the inadequate surveys, the radwaste in shipment No. 16-40 was packaged in the incorrect type of shipping container, the radwaste manifest and shipping paperwork contained numerous errors, and the waste was misclassified in accordance with 10 CFR Part 61. Using NRC Inspection Manual Chapter 0609, Appendix D, Public Radiation Safety Significance Determination Process, the violation was determined to be of very low safety significance (Green) because it was a finding in the transportation branch in which: (1) radiation limits were not exceeded, (2) there was no breach of the package during transit, (3) there were no Certificate of Compliance issues, and (4) the low-level burial ground nonconformance did not involve a 10 CFR 61.55 waste underclassification. The finding has a cross-cutting aspect in the area of human performance, associated with documentation, because the organization failed to maintain complete, accurate, and up-to-date documentation [H.7]. |
| Site: | Columbia |
|---|---|
| Report | IR 05000397/2016009 Section 4OA5 |
| Date counted | Mar 31, 2017 (2017Q1) |
| Type: | NCV: Green |
| cornerstone | Pr Safety |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 93812 |
| Inspectors (proximate) | L Carson N Greene B Tharakanb Tharakanh Gepford L Carson N Greene |
| Violation of: | 10 CFR 20.1501, Surveys and Monitoring 10 CFR 61, LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |