Category:Drawing
MONTHYEARML15043A3952015-02-0606 February 2015 Shine Medical Technologies, Inc. - Application for Construction Permit - Response to Request for Additional Information ML13309B6342013-10-0404 October 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2, Attachment 37, PSAR Figure 19.2.2-1 Rev 1 ML13309B0052013-10-0404 October 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 16 - Drawing 1-HM-SK-001, Rev a Shine Simplified Site ML13221A3652013-08-0808 August 2013 Attachment 18 - Figure 19.2.2-1, Revision 1, Isotope Production System High-Level Flow Diagram ML13309B0412013-02-10010 February 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 7 of 9 ML13309B6262012-08-0303 August 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 24 - Seismic Hazard Assesment Report (Janesville) Rev 4, Part 2 of 2 ML13309B0402012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 6 of 9 ML13309B0392012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 5 of 9 ML13309B0382012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 4 of 9 ML13309B0372012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi) (Part 3 of 9) ML13309B0332012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 9 of 9 ML13309B0322012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 8 of 9 ML13309B6332004-08-31031 August 2004 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2, Attachment 36 - Southern Wisconsin Regional Land Use Drawing Rev 1 2015-02-06
[Table view] |
Text
1 page follows ENCLOSURE 2 ATTACHMENT 37
SHINE MEDICAL TECHNOLOGIES, INC.
SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO ENVIRONMENTAL REQUESTS FOR ADDITIONAL INFORMATION PSAR FIGURE 19.2.2 ISOTOPE PRODUCTION SYSTEM HIGH-LEVEL FLOW DIAGRAM REVISION 1
Chapter 19 -Environmental Review Radio i sotope Facility Desc r ipt i on Figure 19.2.2-1 -Isotope Production System High-Level Flow Diagram !;;o GJ"'C c E '" Tritium Purification Tritium Abbreviations System 99 Mo-Molybdenum-99 D-Deuterium 1-'-FPs -Fission Products LEU-Low enriched uranium ::> 0. Sol'n-Solution T-Tritium TSV-Target solution vessel Neutron Driver Deuterium UREX-Uranium extraction c: E! '5 QJ c: .----------radiolytic gases, FPs-----------..1 Subcritical Assembly 99 Mo Extraction recirculat i ng gas , 1'4---------recomb i ned H z O , FP s--------1 TSV Off-gas System target sol'n Target Sol'n Preparation/
Adjustment no Uranium .-----FP [ Solid Waste J Radwaste System s 1.-.-----spent columns,.
___________
__
effluent 99 Mo Purification (LEU-modified Cintichem)
Product Packaging Punf1Pd Mo Prodta t 1------------glassware , effluent , columns------'
SHINE Medical Technologies Rev.1