| issue date = 01/29/2013
| issue date = 01/29/2013
| title = IR 05000315-12-201, 05000316-12-201; January 2, 2013 Through January 3, 2013, D.C. Cook Nuclear Power Plant, Units 1 and 2; Target Set Inspection- Cover Letter
| title = IR 05000315-12-201, 05000316-12-201; January 2, 2013 through January 3, 2013, D.C. Cook Nuclear Power Plant, Units 1 and 2; Target Set Inspection- Cover Letter
| author name = West G
| author name = West G
| author affiliation = NRC/NSIR/DSO/DDSO
| author affiliation = NRC/NSIR/DSO/DDSO

Revision as of 00:42, 16 February 2018

IR 05000315-12-201, 05000316-12-201; January 2, 2013 through January 3, 2013, D.C. Cook Nuclear Power Plant, Units 1 and 2; Target Set Inspection- Cover Letter
ML13009A202
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 01/29/2013
From: West G
NRC/NSIR/DSO/DDSO
To: Weber L
Indiana Michigan Power Co
Shared Package
ML13009A192 List:
References
IR-12-201
Download: ML13009A202 (3)


See also: IR 05000315/2012201

Text

January 29, 2013

Mr. Larry Weber Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106

SUBJECT: D.C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000315/2012201, 05000316/2012201

Dear Mr. Weber:

On January 3, 2013, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the D.C. Cook Nuclear Power Plant, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on January 3, 2013, with Joel Gebbie, Site Vice President and other members of your staff.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings were identified.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection. L.Weber -2 In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's PARS, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire your entire response "Security-Related Information - Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).

Sincerely,/RA/

Garmon West, Chief Security Training and Support Branch Division of Security Operations Office of Nuclear Security and Incident Response Docket Nos. 05000315, 05000316 License Nos. DPR-58, DPR-74

Enclosure:

Inspection Report 05000315/2012201, 05000316/2012201 and Supplemental Information w/Attachments L.Weber -2 In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's PARS, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire your entire response "Security-Related Information - Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).

Sincerely,/RA/

Garmon West, Chief Security Training and Support Branch Division of Security Operations Office of Nuclear Security and Incident Response Docket Nos. 05000315, 05000316 License Nos. DPR-58, DPR-74

Enclosure:

Inspection Report 05000315/2012201, 05000316/2012201 and Supplemental Information w/Attachments

DISTRIBUTION: R. Albert, NSIR M. Buckley, NSIR N. Simonian, NSIR C. Johnson, NSIR L. Jones, NSIR D. Johnson, NSIR C. Keon, NSIR M. Maley, NSIR C. Adkison, NSIR A. Dimitriadis, RI B. Desai, RII R. Skokowski, RIII M. Haire, RIV ADAMS PACKAGE NO.: ML13009A192 Letter: ML13009A202

Enclosure:

ML13009A247 OFFICE NSIR/DSO/STSB NSIR/DSO/STSB NSIR/DSO/STSB NAME C Keon M. Buckley G. West DATE 1/5/2013 via Email 1/12/2013 1/29/2013 OFFICIAL RECORD COPY