ML070380152: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 2: Line 2:
| number = ML070380152
| number = ML070380152
| issue date = 02/26/2007
| issue date = 02/26/2007
| title = Nine Mile Point, Unit 2, RAI Regarding Inservice Inspection Request for Relief No. 2ISI-001 (TAC No. MD3696)
| title = RAI Regarding Inservice Inspection Request for Relief No. 2ISI-001
| author name = Pickett D V
| author name = Pickett D V
| author affiliation = NRC/NRR/ADRO/DORL/LPLI-1
| author affiliation = NRC/NRR/ADRO/DORL/LPLI-1

Revision as of 15:00, 10 February 2019

RAI Regarding Inservice Inspection Request for Relief No. 2ISI-001
ML070380152
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 02/26/2007
From: Pickett D V
NRC/NRR/ADRO/DORL/LPLI-1
To: O'Connor T J
Nine Mile Point
Pickett D V, NRR/DORL, 415-1364
References
TAC MD3696
Download: ML070380152 (4)


Text

February 26, 2007Mr. Timothy J. O'ConnorVice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P. O. Box 63 Lycoming, NY 13093

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING NINE MILE POINTNUCLEAR STATION, UNIT NO. 2, INSERVICE INSPECTION REQUEST FOR RELIEF NO. 2ISI-001 (TAC NO. MD3696)

Dear Mr. O'Connor:

By letter dated November 16, 2006, Nine Mile Point Nuclear Station, LLC requested NuclearRegulatory Commission (NRC) approval of proposed Request for Relief Number 2ISI-001 forNine Mile Point Unit 2 (NMP2). The request is for permanent relief from the inservice inspection requirements of Title 10 of the Code of Federal Regulations, Part 50, Section50.55a(g) for the volumetric examination of reactor pressure vessel shell circumferential welds for the remaining license period and the license renewal period of extended operation for NMP2.The NRC staff has reviewed the information provided in your request and has determined thatadditional information is needed to complete its review. Enclosed is the NRC staff's request for additional information (RAI). The RAI was discussed with your staff on February 1, 2007, and it was agreed that your response would be provided within 60 days from the date of this letter.Sincerely,/RA/Douglas V. Pickett, Senior Project ManagerPlant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-410

Enclosure:

RAIcc w/encl: See next page February 26, 2007Mr. Timothy J. O'ConnorVice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P. O. Box 63 Lycoming, NY 13093

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING NINE MILE POINTNUCLEAR STATION, UNIT NO. 2, INSERVICE INSPECTION REQUEST FOR RELIEF NO. 2ISI-001 (TAC NO. MD3696)

Dear Mr. O'Connor:

By letter dated November 16, 2006, Nine Mile Point Nuclear Station, LLC requested NuclearRegulatory Commission (NRC) approval of proposed Request for Relief Number 2ISI-001 forNine Mile Point Unit 2 (NMP2). The request is for permanent relief from the inservice inspection requirements of Title 10, Part 50, of the Code of Federal Regulations , Section50.55a(g) for the volumetric examination of reactor pressure vessel shell circumferential welds for the remaining license period and the license renewal period of extended operation for NMP2.The NRC staff has reviewed the information provided in your request and has determined thatadditional information is needed to complete its review. Enclosed is the NRC staff's request for additional information (RAI). The RAI was discussed with your staff on February 1, 2007, and it was agreed that your response would be provided within 60 days from the date of this letter.Sincerely,/RA/Douglas V. Pickett, Senior Project ManagerPlant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-410

Enclosure:

RAIcc w/encl: See next pageDISTRIBUTION

PUBLICRidsNrrPMDPickettRidsNrrLASLittleLPLI-1PDI-1 Reading FileMDavidRidsOgcRpRidsNrrAdesDciCvibRidsNrrAcrsAcnwMailCenterAccession Number: ML070380152NRR-088OFFICELPL1-1/PELPL1-1/PMLPL1-1/LACVIB/BCLPL1-1/BC(A)NAMEMDavidDPickettSLittleMMitchellJBoskaDATE2/22/072/23/072/22/072/23/072/26/07OFFICIAL RECORD COPY Nine Mile Point Nuclear Station cc:

Mr. Michael J. WallacePresident Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group 750 East Pratt Street Baltimore, MD 21202Mr. Mike HeffleySenior Vice President and Chief Nuclear Officer Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401Regional Administrator, Region IU.S. Nuclear Regulatory Commission

475 Allendale Road King of Prussia, PA 19406Resident InspectorU.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093Charles Donaldson, EsquireAssistant Attorney General New York Department of Law 120 Broadway New York, NY 10271Mr. Paul D. EddyElectric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223Mr. Peter R. Smith, PresidentNew York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399Mark J. Wetterhahn, EsquireWinston & Strawn 1700 K Street, NW Washington, DC 20006SupervisorTown of Scriba Route 8, Box 382 Oswego, NY 13126Carey W. Fleming, EsquireSenior Counsel Constellation Generation Group, LLC 750 East Pratt Street, 17th Floor Baltimore, MD 21202 EnclosureREQUEST FOR ADDITIONAL INFORMATIONNINE MILE POINT NUCLEAR STATION, UNIT NO. 2REQUEST FOR RELIEF NO. 2ISI-001By letter dated November 16, 2006, Nine Mile Point Nuclear Station, LLC (the licensee)submitted Request for Relief (RR) No. 2ISI-001 for Nine Mile Point Unit 2 (NMP2) requesting analternative to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI, Table IWB-2500-1, Category B-A, Item Number B1.11, reactor pressure vessel (RPV) circumferential shell welds inspection requirements. RR No. 2ISI-001 is for the second 10-year inservice inspection (ISI) interval, in which NMP2 adopted the 1989 Edition of Section XI of the ASME Code, with no addenda, as the ASME Code of record.

Subarticle IWB-2500 of the ASME Code requires components specified in Table IWB-2500-1 to be examined. Table IWB-2500-1 requires volumetric examination of all RPV shell circumferential welds each inspection interval. The licensee is requesting permanent relief from the above ASME Code requirements for theremaining license period and the license renewal period of extended operation for NMP2. The following information is required to complete the Nuclear Regulatory Commission staff's review of RR No. 2ISI-001.In order for the licensee to request relief for the extended operation period, it must also addressBWRVIP-74, "BWR Reactor Pressure Vessel Inspection and Flaw Evaluation Guidelines,"

dated September 21, 1999. The staff's evaluation of BWRVIP-74 was provided by safety evaluation (SE), dated October 18, 2001 (ML012920549). That SE concluded that Appendix E of the staff's July 28, 1998 SE of BWRVIP-05 ("BWR RPV Shell Weld Inspection Recommendations," dated September 1995) conservatively evaluated BWR RPVs to 64 Effective Full Power Years (EFPY), which is 10 EFPY greater than what is realistically expected for the end of an additional 20-year license renewal period. Therefore, the staff's analysis provides a technical basis for relief from the current ISI requirements of ASME Code,Section XI for volumetric examination of circumferential welds as they may apply for the license renewal period. The October 18, 2001, SE further stated that, to obtain relief, each licensee will have to demonstrate:That, at the end of the renewal period, the circumferential welds will satisfy the limitingconditional failure probabilities for circumferential welds in Appendix E of the staff's July 28, 1998 SE, and that they have implemented operator training and established procedures that limit the frequency of cold overpressure events to the frequency specified in the staff's July 28, 1998 SE.