Line 3: Line 3:
| issue date = 11/23/1994
| issue date = 11/23/1994
| title = Application for Amend to License NPF-63 to TS Re Changes to ECCS Evaluation Model
| title = Application for Amend to License NPF-63 to TS Re Changes to ECCS Evaluation Model
| author name = ROBINSON W R
| author name = Robinson W
| author affiliation = CAROLINA POWER & LIGHT CO.
| author affiliation = CAROLINA POWER & LIGHT CO.
| addressee name =  
| addressee name =  
Line 14: Line 14:
| document type = OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING, TEXT-LICENSE APPLICATIONS & PERMITS
| document type = OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING, TEXT-LICENSE APPLICATIONS & PERMITS
| page count = 2
| page count = 2
| project =
| stage = Request
}}
}}


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:R.ICIER.I E'Y PACCELERATED    RIDS PROCESSIX REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9411300259                DOC.DATE:    94/11/23      NOTARIZED: NO        DOCKET FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina                      05000400 AUTH. NAME            AUTHOR AFFILIATION ROBISON,W.R.          Carolina Power 6 Light Co.
RECIP.NAME            RECIPIENT AFFILIATION                                                          P Document Control Branch (Document Control Desk)
Application for amend to license NPF-63 to TS re changes to l SIZE'+
 
==SUBJECT:==
 
ECCS evaluation model.
DISTRIBUTION CODE: AOOID TITLE:  OR COPIES RECEIVED:LTR Submittal: General Distribution 3  ENCL 0
NOTES:Application for permit renewal filed.                                            05000400 R
RECIPIENT                COPIES              RECIPIENT          COPIES ID CODE/NAME              LTTR ENCL          ID  CODE/NAME      LTTR ENCL PD2-1 LA                        1      1      PD2-1 PD              1    1 LE,N                            1      1 INTERNAL: ACRS                            6      6      FILE  C NT            1    1 NRR/DE/EELB                    1      1      N~RRDRCH/HICB          1    1 NRR/DRPW                        1      1      NRR/DSSA/SPLB          1    1 NRR/DSSA/SRXB                  1      1      NUDOCS-ABSTRACT        1    1 OGC/HDS 2                      1      0 EXTERNAL'OAC                              1      1      NRC PDR                1    1 C
u M'OTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE iVASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 504-2083 ) TO ELIIiIINATEYOUR NA!iIE PROD!
DISTRIBUTION LISTS I'OR DOCUMEN'I'S YOU DON "I'EED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR                    19  ENCL      18
 
Carolina Power & Light Company                                                William R. Robinson PO Box 165                                                                    Vice President New Hill NC 27562                                                              Harris Nuclear Plant NOV 2 3 >994 File:    HO-941104                                                      SERIAL: HNP-94-092 10 CFR 50.46 United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington,        DC    20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 EMERGENCY CORE COOLING SYSTEM EUALUATION MODEL CHANGES Gentlemen:
The purpose        of this letter is to submit information required pursuant to 10 CFR 50.46(a)(3)(ii) for the Shearon Harris Nuclear Power Plant (SHNPP) regarding the estimated effect of changes or errors in Emergency Core Cooling System (ECCS) evaluation models or in the application of the models. This submittal fulfills the requirements for a 30-day report.
Westinghouse analyzed the SBLOCA event for the cycle 6 reload using the NOTRUMP Evaluation Model previously reviewed and approved by the NRC. The analysis indicated that the most limiting PCT resulting from a SBLOCA would be 2011 'F (Reference CP&L's annual report dated June 9, 1994, NLS-94-046).
Westinghouse        has informed CP&L of several model errors which result in a net reduction in margin to the PCT acceptance criteria. The new PCT for HNP is 2199 'F.        The calculated performance of the SHNPP ECCS continues to meet the performance acceptance criteria specified in 10 CFR 50.46(b)(1), i.e., the calculated maximum PCT is less than 2200'F.
The enclosure        to this letter provides a Margin Utilization Table for the                  SBLOCA analyses      of record in a format consistent with past reports.
Questions regarding          this matter    may be  referred to Mr. R. W. Prunty at (919) 362-2030.
Yours very  truly, SDC/sdc
 
==Enclosure:==
 
cc:    Mr. S. D. Ebneter Mr. S. A. Elrod                9411300259 941123 Mr. N. B. Le                    PDR      ADOCK 05000400 P                      PDR
    $ 80 ~  tr1    State Road 1134 New Hill NC  Tel 919362-2502  Fax 919 362-6950}}

Latest revision as of 19:56, 3 February 2020

Application for Amend to License NPF-63 to TS Re Changes to ECCS Evaluation Model
ML18011A688
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 11/23/1994
From: Robinson W
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18011A689 List:
References
HNP-94-092, HNP-94-92, HO-941104, NUDOCS 9411300259
Download: ML18011A688 (2)


Text

R.ICIER.I E'Y PACCELERATED RIDS PROCESSIX REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9411300259 DOC.DATE: 94/11/23 NOTARIZED: NO DOCKET FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina 05000400 AUTH. NAME AUTHOR AFFILIATION ROBISON,W.R. Carolina Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION P Document Control Branch (Document Control Desk)

Application for amend to license NPF-63 to TS re changes to l SIZE'+

SUBJECT:

ECCS evaluation model.

DISTRIBUTION CODE: AOOID TITLE: OR COPIES RECEIVED:LTR Submittal: General Distribution 3 ENCL 0

NOTES:Application for permit renewal filed. 05000400 R

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-1 LA 1 1 PD2-1 PD 1 1 LE,N 1 1 INTERNAL: ACRS 6 6 FILE C NT 1 1 NRR/DE/EELB 1 1 N~RRDRCH/HICB 1 1 NRR/DRPW 1 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS 2 1 0 EXTERNAL'OAC 1 1 NRC PDR 1 1 C

u M'OTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 504-2083 ) TO ELIIiIINATEYOUR NA!iIE PROD!

DISTRIBUTION LISTS I'OR DOCUMEN'I'S YOU DON "I'EED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 19 ENCL 18

Carolina Power & Light Company William R. Robinson PO Box 165 Vice President New Hill NC 27562 Harris Nuclear Plant NOV 2 3 >994 File: HO-941104 SERIAL: HNP-94-092 10 CFR 50.46 United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 EMERGENCY CORE COOLING SYSTEM EUALUATION MODEL CHANGES Gentlemen:

The purpose of this letter is to submit information required pursuant to 10 CFR 50.46(a)(3)(ii) for the Shearon Harris Nuclear Power Plant (SHNPP) regarding the estimated effect of changes or errors in Emergency Core Cooling System (ECCS) evaluation models or in the application of the models. This submittal fulfills the requirements for a 30-day report.

Westinghouse analyzed the SBLOCA event for the cycle 6 reload using the NOTRUMP Evaluation Model previously reviewed and approved by the NRC. The analysis indicated that the most limiting PCT resulting from a SBLOCA would be 2011 'F (Reference CP&L's annual report dated June 9, 1994, NLS-94-046).

Westinghouse has informed CP&L of several model errors which result in a net reduction in margin to the PCT acceptance criteria. The new PCT for HNP is 2199 'F. The calculated performance of the SHNPP ECCS continues to meet the performance acceptance criteria specified in 10 CFR 50.46(b)(1), i.e., the calculated maximum PCT is less than 2200'F.

The enclosure to this letter provides a Margin Utilization Table for the SBLOCA analyses of record in a format consistent with past reports.

Questions regarding this matter may be referred to Mr. R. W. Prunty at (919) 362-2030.

Yours very truly, SDC/sdc

Enclosure:

cc: Mr. S. D. Ebneter Mr. S. A. Elrod 9411300259 941123 Mr. N. B. Le PDR ADOCK 05000400 P PDR

$ 80 ~ tr1 State Road 1134 New Hill NC Tel 919362-2502 Fax 919 362-6950