{{#Wiki_filter:APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION TABLE OF CONTENTS PAGE 5E.0 REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM                          5E.1-1 CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION 5E.1 REDUCTION IN CONTAINMENT PRESTRESS                                        5E.1-1 5E.1.1  DESIGN BASIS                                                      5E.1-1 5E.1.2  DESIGN CRITERIA FOR PRESTRESS                                    5E.1-1 5E.1.3  DESIGN REANALYSIS                                                5E.1-1 5E.1.3.1    Summary of Calvert Cliffs Containment Reanalysis      5E.1-2 5E.
{{#Wiki_filter:APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION TABLE OF CONTENTS PAGE


==1.4  REFERENCES==
5E.0 REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM 5E.1-1 CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION 5E.1 REDUCTION IN CONTAINMENT PRESTRESS 5E.1-1 5E.1.1 DESIGN BASIS 5E.1-1 5E.1.2 DESIGN CRITERIA FOR PRESTRESS 5E.1-1 5E.1.3 DESIGN REANALYSIS 5E.1-1 5E.1.3.1 Summary of Calvert Cliffs Containment Reanalysis 5E.1-2 5E.
5E.1-2 5E.2 LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON                         5E.2-1 CORROSION 5E.2.1 DISCOVERY OF CORROSION                                            5E.2-1 5E.2.2  CAUSE OF VERTICAL TENDON CORROSION                                5E.2-1 5E.2.3  LONG-TERM CORRECTIVE ACTIONS                                      5E.2-1 5E.2.3.1   Future Wire Breakage Prediction Model (a.k.a. Weibull 5E.2-2 Model) 5E.2.3.2    Selection Criteria for Corroded Tendons to be        5E.2-3 Replaced 5E.2.3.3    Stressing Sequence of Tendons Replaced and            5E.2-4 Restressed 5E.2.3.4    Tendon Bearing Plate Concrete Void Repairs            5E.2-4 5E.2.4  ACCEPTABILITY OF CONCRETE CONTAINMENTS                            5E.2-4 5E.2.5  ENHANCED VERTICAL TENDON INSPECTIONS                              5E.2-5 5E.2.6  CONTAINMENT PRESSURE TEST                                        5E.2-5 5E.


==2.REFERENCES==
==1.4 REFERENCES==
5E.2-6 5E.3 EVALUATION OF PLANT OPERATING LICENSE EXTENSION ON                        5E.3-1 TENDON SYSTEM 5E.3.1 TENDON POPULATIONS                                                5E.3-1 5E.3.2 ORIGINAL TENDON PRESTRESS LOSSES                                  5E.3-1 5E.3.3  NEW TENDON PRESTRESS LOSSES                                      5E.3-2 5E.
5E.1-2 5E.2 LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON 5E.2-1 CORROSION 5E.2.1 DISCOVERY OF CORROSION 5E.2-1 5E.2.2 CAUSE OF VERTICAL TENDON CORROSION 5E.2-1 5E.2.3 LONG-TERM CORRECTIVE ACTIONS 5E.2-1 5E.2.3.1 Future Wire Breakage Prediction Model (a.k.a. Weibull 5E.2-2 Model) 5E.2.3.2 Selection Criteria for Corroded Tendons to be 5E.2-3 Replaced 5E.2.3.3 Stressing Sequence of Tendons Replaced and 5E.2-4 Restressed 5E.2.3.4 Tendon Bearing Plate Concrete Void Repairs 5E.2-4 5E.2.4 ACCEPTABILITY OF CONCRETE CONTAINMENTS 5E.2-4 5E.2.5 ENHANCED VERTICAL TENDON INSPECTIONS 5E.2-5 5E.2.6 CONTAINMENT PRESSURE TEST 5E.2-5 5E.


==3.REFERENCES==
==2.7 REFERENCES==
5E.3-3 5E.4 VERTICAL TENDON PRESTRESS LOSSES DUE TO FUTURE WIRE                      5E.4-1 BREAKAGE 5E.5 CONCLUSION                                                                5E.5-1 CALVERT CLIFFS UFSAR                    5E-i                                  Rev. 47
5E.2-6 5E.3 EVALUATION OF PLANT OPERATING LICENSE EXTENSION ON 5E.3-1 TENDON SYSTEM 5E.3.1 TENDON POPULATIONS 5E.3-1 5E.3.2 ORIGINAL TENDON PRESTRESS LOSSES 5E.3-1 5E.3.3 NEW TENDON PRESTRESS LOSSES 5E.3-2 5E.


APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF TABLES TITLE                                                        PAGE 5E-1    STRESS ANALYSIS RESULTS                            5E.1-3 5E-2    PRESTRESS COMPARISON IN VERTICAL TENDON SYSTEM    5E.2-7 5E-3    UNIT 1 TENDON POPULATIONS AND EFFECTIVE LIVES      5E.3-4 5E-4    UNIT 2 TENDON POPULATIONS AND EFFECTIVE LIVES      5E.3-5 CALVERT CLIFFS UFSAR              5E-ii                        Rev. 47
==3.4 REFERENCES==
5E.3-3 5E.4 VERTICAL TENDON PRESTRESS LOSSES DUE TO FUTURE WIRE 5E.4-1 BREAKAGE 5E.5 CONCLUSION 5E.5-1


APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF FIGURES FIGURE 5E-1         RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1 5E-2         RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1 CALVERT CLIFFS UFSAR              5E-iii                          Rev. 47
CALVERT CLIFFS UFSAR 5E-i Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF TABLES TITLE PAGE 5E-1 STRESS ANALYSIS RESULTS 5E.1-3 5E-2 PRESTRESS COMPARISON IN VERTICAL TENDON SYSTEM 5E.2-7 5E-3 UNIT 1 TENDON POPULATIONS AND EFFECTIVE LIVES 5E.3-4 5E-4 UNIT 2 TENDON POPULATIONS AND EFFECTIVE LIVES 5E.3-5


APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF ACRONYMS ASME       American Society of Mechanical Engineers CCNPP     Calvert Cliffs Nuclear Power Plant ISI       Inservice Inspection NRC       Nuclear Regulatory Commission PSC       Precision Surveillance Corporation CALVERT CLIFFS UFSAR                     5E-iv                 Rev. 47}}
CALVERT CLIFFS UFSAR 5E-ii Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF FIGURES FIGURE 5E-1 RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1 5E-2 RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1
 
CALVERT CLIFFS UFSAR 5E-iii Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF ACRONYMS ASME American Society of Mechanical Engineers CCNPP Calvert Cliffs Nuclear Power Plant ISI Inservice Inspection NRC Nuclear Regulatory Commission PSC Precision Surveillance Corporation
 
CALVERT CLIFFS UFSAR 5E-iv Rev. 47}}

Latest revision as of 19:45, 19 November 2024

2 to Updated Final Safety Analysis Report, Chapter 5, Appendix 5E, Reduction in Containment Prestress and Long-Term Corrective Actions for Vertical Tendon Corrosion
ML21278A143
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 09/07/2021
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21278A102 List: ... further results
References
NEI 99-04
Download: ML21278A143 (4)


Text

APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION TABLE OF CONTENTS PAGE

5E.0 REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM 5E.1-1 CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION 5E.1 REDUCTION IN CONTAINMENT PRESTRESS 5E.1-1 5E.1.1 DESIGN BASIS 5E.1-1 5E.1.2 DESIGN CRITERIA FOR PRESTRESS 5E.1-1 5E.1.3 DESIGN REANALYSIS 5E.1-1 5E.1.3.1 Summary of Calvert Cliffs Containment Reanalysis 5E.1-2 5E.

1.4 REFERENCES

5E.1-2 5E.2 LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON 5E.2-1 CORROSION 5E.2.1 DISCOVERY OF CORROSION 5E.2-1 5E.2.2 CAUSE OF VERTICAL TENDON CORROSION 5E.2-1 5E.2.3 LONG-TERM CORRECTIVE ACTIONS 5E.2-1 5E.2.3.1 Future Wire Breakage Prediction Model (a.k.a. Weibull 5E.2-2 Model) 5E.2.3.2 Selection Criteria for Corroded Tendons to be 5E.2-3 Replaced 5E.2.3.3 Stressing Sequence of Tendons Replaced and 5E.2-4 Restressed 5E.2.3.4 Tendon Bearing Plate Concrete Void Repairs 5E.2-4 5E.2.4 ACCEPTABILITY OF CONCRETE CONTAINMENTS 5E.2-4 5E.2.5 ENHANCED VERTICAL TENDON INSPECTIONS 5E.2-5 5E.2.6 CONTAINMENT PRESSURE TEST 5E.2-5 5E.

2.7 REFERENCES

5E.2-6 5E.3 EVALUATION OF PLANT OPERATING LICENSE EXTENSION ON 5E.3-1 TENDON SYSTEM 5E.3.1 TENDON POPULATIONS 5E.3-1 5E.3.2 ORIGINAL TENDON PRESTRESS LOSSES 5E.3-1 5E.3.3 NEW TENDON PRESTRESS LOSSES 5E.3-2 5E.

3.4 REFERENCES

5E.3-3 5E.4 VERTICAL TENDON PRESTRESS LOSSES DUE TO FUTURE WIRE 5E.4-1 BREAKAGE 5E.5 CONCLUSION 5E.5-1

CALVERT CLIFFS UFSAR 5E-i Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF TABLES TITLE PAGE 5E-1 STRESS ANALYSIS RESULTS 5E.1-3 5E-2 PRESTRESS COMPARISON IN VERTICAL TENDON SYSTEM 5E.2-7 5E-3 UNIT 1 TENDON POPULATIONS AND EFFECTIVE LIVES 5E.3-4 5E-4 UNIT 2 TENDON POPULATIONS AND EFFECTIVE LIVES 5E.3-5

CALVERT CLIFFS UFSAR 5E-ii Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF FIGURES FIGURE 5E-1 RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1 5E-2 RING GIRDER BEARING PLATE PLAN - BEARING PLATE REPAIRS AND TENDON STRESSING SEQUENCE - UNIT 1

CALVERT CLIFFS UFSAR 5E-iii Rev. 47 APPENDIX 5E REDUCTION IN CONTAINMENT PRESTRESS AND LONG-TERM CORRECTIVE ACTIONS FOR VERTICAL TENDON CORROSION LIST OF ACRONYMS ASME American Society of Mechanical Engineers CCNPP Calvert Cliffs Nuclear Power Plant ISI Inservice Inspection NRC Nuclear Regulatory Commission PSC Precision Surveillance Corporation

CALVERT CLIFFS UFSAR 5E-iv Rev. 47