ML080160211: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
| number = ML080160211 | | number = ML080160211 | ||
| issue date = 01/30/2008 | | issue date = 01/30/2008 | ||
| title = | | title = Closure of Confirmatory Action Letter NRR-07-022 | ||
| author name = Haney C | | author name = Haney C | ||
| author affiliation = NRC/NRR/ADRO/DORL | | author affiliation = NRC/NRR/ADRO/DORL | ||
| addressee name = Hamilton B | | addressee name = Hamilton B | ||
| addressee affiliation = Duke Power Co | | addressee affiliation = Duke Power Co | ||
| docket = 05000270, 05000287 | | docket = 05000270, 05000287 | ||
Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:January 30, 2008 | {{#Wiki_filter:January 30, 2008 Mr. Bruce H. Hamilton Vice President, Oconee Site Duke Power Company LLC 7800 Rochester Highway Seneca, SC 29672 | ||
Mr. Bruce H. Hamilton Vice President, Oconee Site Duke Power Company LLC 7800 Rochester Highway Seneca, SC 29672 | |||
==SUBJECT:== | ==SUBJECT:== | ||
OCONEE NUCLEAR STATION, UNITS 2 AND 3 - CLOSURE OF CONFIRMATORY ACTION LETTER NRR-07-022 (TAC NOS. MD4166 AND MD4167) | OCONEE NUCLEAR STATION, UNITS 2 AND 3 - CLOSURE OF CONFIRMATORY ACTION LETTER NRR-07-022 (TAC NOS. MD4166 AND MD4167) | ||
==Dear Mr. Hamilton:== | ==Dear Mr. Hamilton:== | ||
On March 27, 2007, the U.S. Nuclear Regulatory Commission (NRC) issued Confirmatory Action Letter (CAL) No. NRR-07-022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML070790113) regarding dissimilar metal welds in the pressurizers at Oconee Nuclear Station, Units 2 and 3. This letter acknowledges receipt of your letter dated December 13, 2007 (ADAMS Accession No. ML073532226) informing the NRC of actions taken in response to this CAL at Oconee Unit 3. The NRC has previously acknowledged actions taken at Oconee Unit 2 by letter dated September 12, 2007 (ADAMS Accession No. ML072130497). | On March 27, 2007, the U.S. Nuclear Regulatory Commission (NRC) issued Confirmatory Action Letter (CAL) No. NRR-07-022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML070790113) regarding dissimilar metal welds in the pressurizers at Oconee Nuclear Station, Units 2 and 3. This letter acknowledges receipt of your letter dated December 13, 2007 (ADAMS Accession No. ML073532226) informing the NRC of actions taken in response to this CAL at Oconee Unit 3. The NRC has previously acknowledged actions taken at Oconee Unit 2 by letter dated September 12, 2007 (ADAMS Accession No. ML072130497). | ||
In your letter, you informed us of the mitigative actions taken at Oconee Unit 3, which consisted of the application of full structural weld overlays to the Alloy 82/182 welds of the pressurizer surge, spray, and safety/relief nozzle and safe end welds. The results of the ultrasonic examinations were included in the letter. | |||
In your letter, you informed us of the mitigative actions taken at Oconee Unit 3, which consisted of the application of full structural weld overlays to the Alloy 82/182 welds of the pressurizer surge, spray, and safety/relief nozzle and safe end welds. The results of the ultrasonic examinations were included in the letter. | |||
Based on your letter, the NRC has found that all the commitments listed in the CAL and supporting commitment letters (ADAMS Accession Nos. ML070390049 and ML070600169) have been met for Oconee Units 2 and 3. No further response is required regarding the CAL. | Based on your letter, the NRC has found that all the commitments listed in the CAL and supporting commitment letters (ADAMS Accession Nos. ML070390049 and ML070600169) have been met for Oconee Units 2 and 3. No further response is required regarding the CAL. | ||
We consider the CAL closed. As such, it is no longer necessary to implement enhanced inspection and leakage monitoring requirements for the reactor coolant system. Based on these actions, TAC No. MD4167 will be closed. TAC No. MD4166 was closed previously. | We consider the CAL closed. As such, it is no longer necessary to implement enhanced inspection and leakage monitoring requirements for the reactor coolant system. Based on these actions, TAC No. MD4167 will be closed. TAC No. MD4166 was closed previously. | ||
Thank you for informing us of the actions documented in your letter. These actions may be examined during a future NRC inspection of your facility. | |||
Thank you for informing us of the actions documented in your letter. These actions may be examined during a future NRC inspection of your facility. | Current NRC guidance regarding CALs is contained in the NRC Enforcement Policy and the NRC Enforcement Manual, which are available at the NRC web site at http://www.nrc.gov/about-nrc/regulatory/enforcement.html (click on Enforcement Policy or Enforcement Guidance) or by contacting the Government Printing Office (GPO) toll-free at 1-888-293-6498. The GPO is open from 7:00 a.m. to 9:00 p.m. EST, Monday through Friday (except Federal holidays). | ||
Current NRC guidance regarding CALs is contained in the NRC Enforcement Policy and the NRC Enforcement Manual, which are available at the NRC web site at http://www.nrc.gov/about-nrc/regulatory/enforcement.html (click on Enforcement Policy or Enforcement Guidance) or by contacting the Government Printing Office (GPO) toll-free at 1-888-293-6498. The GPO is open from 7:00 a.m. to 9:00 p.m. EST, Monday through Friday (except Federal holidays). | |||
B. Hamilton In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room or from the NRC=s document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm.html. | |||
Sincerely, | |||
/RA/ | |||
Catherine Haney, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-270 and 50-287 cc: See next page | |||
Ms. Kathryn B. Nolan Senior Counsel Duke Energy Carolinas, LLC 526 South Church Street - EC07H Charlotte, NC 28202}} | ML080160211 NRR-106 OFFICE DCI/CPNB DCI/CPNB LPL2-1/PM LPL2-1/LA LPL2-1/BC (A) | ||
NAME TLupold TChan LOlshan MOBrien JStang DATE 1/17/08 1/17/08 1/16/08 01/16/08 1/18/08 OFFICE DCI/D DRS/D RII DORL/D NAME MEvans HChristensen CHaney for JShea By email DATE 1/17/08 1/30/08 1/30/08 Oconee Nuclear Station, Units 1, 2, and 3 January 31, 2008 cc: | |||
Mr. Bruce H. Hamilton Vice President, Oconee Site Mr. Leonard G. Green Duke Power Company LLC Assistant Attorney General 7800 Rochester Highway NC Department of Justice Seneca, SC 29672 P.O. Box 629 Raleigh, NC 27602 Ms. Lisa F. Vaughn Associate General Counsel and Managing Mr. R. L. Gill, Jr. | |||
Attorney Manager - Nuclear Regulatory Duke Energy Carolinas, LLC Issues and Industry Affairs 526 South Church Street - EC07H Duke Power Company LLC Charlotte, North Carolina 28202 526 S. Church St. | |||
Mail Stop EC05P Manager, LIS Charlotte, NC 28202 NUS Corporation 2650 McCormick Dr., 3rd Floor Division of Radiation Protection Clearwater, FL 34619-1035 NC Dept of Environment, Health, & Natural Resources Senior Resident Inspector 3825 Barrett Dr. | |||
U.S. Nuclear Regulatory Commission Raleigh, NC 27609-7721 7812B Rochester Highway Seneca, SC 29672 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Mr. Henry Porter, Director Westinghouse Electric Company Division of Radioactive Waste Management 6000 Fairview Road Bureau of Land and Waste Management 12th Floor Dept. of Health and Env. Control Charlotte, NC 28210 2600 Bull St. | |||
Columbia, SC 29201-1708 Mr. Henry Barron Group Vice President, Nuclear Generation Mr. Michael A. Schoppman and Chief Nuclear Officer Framatome ANP P.O. Box 1006-EC07H 1911 North Ft. Myer Dr. Charlotte, NC 28201-1006 Suite 705 Rosslyn, VA 22209 Mr. Charles Brinkman Director, Washington Operations Mr. B. G. Davenport Westinghouse Electric Company Regulatory Compliance Manager 12300 Twinbrook Parkway, Suite 330 Oconee Nuclear Site Rockville, MD 20852 Duke Energy Corporation ON03RC Ms. Kathryn B. Nolan 7800 Rochester Highway Senior Counsel Seneca, SC 29672 Duke Energy Carolinas, LLC 526 South Church Street - EC07H Charlotte, NC 28202}} |
Latest revision as of 14:37, 22 March 2020
ML080160211 | |
Person / Time | |
---|---|
Site: | Oconee |
Issue date: | 01/30/2008 |
From: | Catherine Haney Plant Licensing Branch III-2 |
To: | Brandi Hamilton Duke Power Co |
Olshan L N, NRR/DORL, 415-1419 | |
References | |
TAC MD4166, TAC MD4167, NRR-07-022 | |
Download: ML080160211 (4) | |
Text
January 30, 2008 Mr. Bruce H. Hamilton Vice President, Oconee Site Duke Power Company LLC 7800 Rochester Highway Seneca, SC 29672
SUBJECT:
OCONEE NUCLEAR STATION, UNITS 2 AND 3 - CLOSURE OF CONFIRMATORY ACTION LETTER NRR-07-022 (TAC NOS. MD4166 AND MD4167)
Dear Mr. Hamilton:
On March 27, 2007, the U.S. Nuclear Regulatory Commission (NRC) issued Confirmatory Action Letter (CAL) No. NRR-07-022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML070790113) regarding dissimilar metal welds in the pressurizers at Oconee Nuclear Station, Units 2 and 3. This letter acknowledges receipt of your letter dated December 13, 2007 (ADAMS Accession No. ML073532226) informing the NRC of actions taken in response to this CAL at Oconee Unit 3. The NRC has previously acknowledged actions taken at Oconee Unit 2 by letter dated September 12, 2007 (ADAMS Accession No. ML072130497).
In your letter, you informed us of the mitigative actions taken at Oconee Unit 3, which consisted of the application of full structural weld overlays to the Alloy 82/182 welds of the pressurizer surge, spray, and safety/relief nozzle and safe end welds. The results of the ultrasonic examinations were included in the letter.
Based on your letter, the NRC has found that all the commitments listed in the CAL and supporting commitment letters (ADAMS Accession Nos. ML070390049 and ML070600169) have been met for Oconee Units 2 and 3. No further response is required regarding the CAL.
We consider the CAL closed. As such, it is no longer necessary to implement enhanced inspection and leakage monitoring requirements for the reactor coolant system. Based on these actions, TAC No. MD4167 will be closed. TAC No. MD4166 was closed previously.
Thank you for informing us of the actions documented in your letter. These actions may be examined during a future NRC inspection of your facility.
Current NRC guidance regarding CALs is contained in the NRC Enforcement Policy and the NRC Enforcement Manual, which are available at the NRC web site at http://www.nrc.gov/about-nrc/regulatory/enforcement.html (click on Enforcement Policy or Enforcement Guidance) or by contacting the Government Printing Office (GPO) toll-free at 1-888-293-6498. The GPO is open from 7:00 a.m. to 9:00 p.m. EST, Monday through Friday (except Federal holidays).
B. Hamilton In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room or from the NRC=s document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm.html.
Sincerely,
/RA/
Catherine Haney, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-270 and 50-287 cc: See next page
ML080160211 NRR-106 OFFICE DCI/CPNB DCI/CPNB LPL2-1/PM LPL2-1/LA LPL2-1/BC (A)
NAME TLupold TChan LOlshan MOBrien JStang DATE 1/17/08 1/17/08 1/16/08 01/16/08 1/18/08 OFFICE DCI/D DRS/D RII DORL/D NAME MEvans HChristensen CHaney for JShea By email DATE 1/17/08 1/30/08 1/30/08 Oconee Nuclear Station, Units 1, 2, and 3 January 31, 2008 cc:
Mr. Bruce H. Hamilton Vice President, Oconee Site Mr. Leonard G. Green Duke Power Company LLC Assistant Attorney General 7800 Rochester Highway NC Department of Justice Seneca, SC 29672 P.O. Box 629 Raleigh, NC 27602 Ms. Lisa F. Vaughn Associate General Counsel and Managing Mr. R. L. Gill, Jr.
Attorney Manager - Nuclear Regulatory Duke Energy Carolinas, LLC Issues and Industry Affairs 526 South Church Street - EC07H Duke Power Company LLC Charlotte, North Carolina 28202 526 S. Church St.
Mail Stop EC05P Manager, LIS Charlotte, NC 28202 NUS Corporation 2650 McCormick Dr., 3rd Floor Division of Radiation Protection Clearwater, FL 34619-1035 NC Dept of Environment, Health, & Natural Resources Senior Resident Inspector 3825 Barrett Dr.
U.S. Nuclear Regulatory Commission Raleigh, NC 27609-7721 7812B Rochester Highway Seneca, SC 29672 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Mr. Henry Porter, Director Westinghouse Electric Company Division of Radioactive Waste Management 6000 Fairview Road Bureau of Land and Waste Management 12th Floor Dept. of Health and Env. Control Charlotte, NC 28210 2600 Bull St.
Columbia, SC 29201-1708 Mr. Henry Barron Group Vice President, Nuclear Generation Mr. Michael A. Schoppman and Chief Nuclear Officer Framatome ANP P.O. Box 1006-EC07H 1911 North Ft. Myer Dr. Charlotte, NC 28201-1006 Suite 705 Rosslyn, VA 22209 Mr. Charles Brinkman Director, Washington Operations Mr. B. G. Davenport Westinghouse Electric Company Regulatory Compliance Manager 12300 Twinbrook Parkway, Suite 330 Oconee Nuclear Site Rockville, MD 20852 Duke Energy Corporation ON03RC Ms. Kathryn B. Nolan 7800 Rochester Highway Senior Counsel Seneca, SC 29672 Duke Energy Carolinas, LLC 526 South Church Street - EC07H Charlotte, NC 28202