| issue date = 01/17/2012
| issue date = 01/17/2012
| title = Request for Additional Information Amendment to Change Emergency Action Levels
| title = Request for Additional Information Amendment to Change Emergency Action Levels
| author name = Feintuch K D
| author name = Feintuch K
| author affiliation = NRC/NRR/DORL/LPLIII-1
| author affiliation = NRC/NRR/DORL/LPLIII-1
| addressee name = Wells P
| addressee name = Wells P
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:UNITED NUCLEAR REGULATORY WASHINGTON, D.C. 20555-0001 January 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785 DUANE ARNOLD ENERGY CENTER -REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (T AC ME6508)  
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785
 
==SUBJECT:==
DUANE ARNOLD ENERGY CENTER - REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (TAC ME6508)


==Dear Mr. Wells:==
==Dear Mr. Wells:==
By letter dated May 31, 2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML 111540279
 
[package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
By letter dated May 31, 2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI) (ADAMS Accession No. ML 12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012. The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources.
The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI)
Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAt Sincerely, Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-331  
(ADAMS Accession No. ML12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources.
Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAt Sincerely, Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-331


==Enclosure:==
==Enclosure:==
As Stated cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION DUANE ARNOLD ENERGY CENTER LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY PLAN DOCKET NO. 50-331 By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [packageD, NextEra Energy Duane Arnold, LLC requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
The licensee stated that the license amendment request was for revision of selected EALs and not the entire EAL scheme. However, in effect, the licensee actually submitted their entire EAL scheme and is therefore the scope of this review, i.e., the acceptability of the proposed EAL scheme to meet the standards of 10 CFR 50.47 and the requirements of 10 CFR Appendix E.
In addition, the staff noted numerous changes to the previously approved EAL scheme that were not specifically noted as those requiring prior NRC approval. These changes were also reviewed as part of this license amendment due to the importance of ensuring an acceptable EAL scheme is in place as all offsite actions are predicated on timely and accurate EAL classifications.
DAEC's letter stated that the current DAEC EAL scheme is based on generic development guidance from Nuclear Energy Institute (NEI) document entitled NEI-99-01, "Methodology for Development of Emergency Action Levels," Revision 4, January 2003, (ADAMS Accession No. ML041470143). Since 1992, numerous enhancements and clarification efforts have been made to the generic EAL development guidance resulting in the most recent document, NEI 99-01, Revision 5, "Methodology for Development of Emergency Action Levels," (ADAMS Accession No. ML080450149), which was found to be acceptable for use as generic EAL development guidance by the Nuclear Regulatory Commission (NRC) staff by letter dated
.February 22, 2008 (ADAMS Accession No. ML080430535).
The proposed EAL scheme was developed using the generic development guidance from NEI 99-01, Revision 5 with numerous differences and deviations based upon design criteria applicable to the site as well as licensee preferences for terminology, format, and other licensee-desired modifications to the generic EAL scheme development guidance provided in NEI 99-01 Revision 5.
Attached are the requests for additional information (RAJ) items to facilitate the technical review being conducted by the Operating Reactor Licensing and Outreach Branch staff. Timely and accurate response to these draft RAls is requested.
Enclosure
                                                  -2
: 1. Section 3.0 of Enclosure 1, "Evaluation of Proposed Change" the last sentence in the last paragraph states that any changes to the approved ICs [initiating conditions) and EALs will be made in accordance with 10 CFR SO.S4(q). It is the expectation of the staff that changes to the EAL basis information and operating modes will be controlled in the same way as any changes to the approved ICs and EALs. Please explain the rationale for not controlling the EAL Basis Document, as a whole, in accordance with 10 CFR SO.S4(q) or revise this statement accordingly.
: 2. EAL RU2.2: The use of "offscale high" readings for EAL thresholds is problematic as it is difficult to differentiate between failed instrumentation and actual plant conditions. Please explain how you will differentiate between the two, in the time allowed, for EAL declaration purposes and how this wording will not result in erroneous declarations, or revise accordingly.
: 3. EAL RA2: The staff requires further justification for the removal of the level threshold previously approved for EAL RA2.3. The proposed justification for the change is confusing in that it uses a calculation as a basis for the change when in fact there are three unique EAL thresholds expected for this EAL. One is based upon a valid Hi-Rad alarm from RM 9178, a valid reading> 100 millirem/hr from RM-9178, and indication of lowering fuel pool water level from L1-3413. Redundancy is expected for this EAL due to the significance of the concern and the availability of instrumentation. Please provide further justification that supports this revision, or revise accordingly.
: 4. EAL RA3: Please explain why the Secondary Alarm Station is used as a threshold for this EAL as this EAL only requires either the Control Room, and either the Central Alarm Station or Secondary Alarm Station, not both (typically). Please justify or revise accordingly.
S. EAL CG1: The staff noted an apparent typographical error in the IC. In addition, the staff recommends developing this EAL using the table as provided in the endorsed EAL scheme development guidance as it aids in clarifying the logic for this EAL, however, the staff has no technical opposition to the proposed format and wording. Also, please move the wording
  " .. .for 30 minutes or longer" from the bulleted list of conditions provided in CG 1.2 to the threshold for "RPV level cannot be monitored." This is a known error in the guidance document which will be corrected in a future revision.
: 6. EAL EU1: Please provide basis information related to how security events at the ISFSI
[independent spent fuel storage installations] are classified.
: 7. EAL HU2.1: Note that consideration of"... adjacent areas" was removed as history had shown this to be an area of confusion throughout the nuclear industry and resulted in a delay in classification in some cases.
: 8. EAL HA 1: Please be aware that the areas of concern are expected to be areas where equipment necessary for safe operation, shutdown, and/or cooldown are located AND where the equipment is at risk from the given hazard. For example, not all areas are susceptible to vehicle crashes, high winds, tornados, or turbine blade failure. Please ensure to consider this when developing the list.
                                                - 3
: 9. EAL HA2: Please provide the list of areas applicable to this EAL.
: 10. EAL HA32: Please revise the list of areas applicable to this EAL to ensure consistent, and accurate, EAL declaration. Only those areas that contain equipment that must be operated locally for safe operation. safe shutdown, or safe cooldown should be listed. If an area does not contain equipment that must be operated locally. then consideration for not including this area should be given. Note that the need to operate the equipment is not a threshold, i.e.,
the impediment to access an area, developed as per the above guidance. is the expectation for this EAL. Also. consider adding guidance information that allows the decision-maker to use reasonable judgment when considering declaring this EAL. For example, a small CO 2 bottle leaking in a large room/area may not warrant declaration.
Januasy 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785


As Stated cc w/encl: Distribution via Listserv REQUEST FOR ADDITIONAL INFORMATION DUANE ARNOLD ENERGY CENTER LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY PLAN DOCKET NO. 50-331 By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML 111540279
==SUBJECT:==
[packageD, NextEra Energy Duane Arnold, LLC requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
DUANE ARNOLD ENERGY CENTER - REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (TAC ME6508)
The licensee stated that the license amendment request was for revision of selected EALs and not the entire EAL scheme. However, in effect, the licensee actually submitted their entire EAL scheme and is therefore the scope of this review, i.e., the acceptability of the proposed EAL scheme to meet the standards of 10 CFR 50.47 and the requirements of 10 CFR Appendix E. In addition, the staff noted numerous changes to the previously approved EAL scheme that were not specifically noted as those requiring prior NRC approval.
These changes were also reviewed as part of this license amendment due to the importance of ensuring an acceptable EAL scheme is in place as all offsite actions are predicated on timely and accurate EAL classifications.
DAEC's letter stated that the current DAEC EAL scheme is based on generic development guidance from Nuclear Energy Institute (NEI) document entitled NEI-99-01, "Methodology for Development of Emergency Action Levels," Revision 4, January 2003, (ADAMS Accession No. ML041470143).
Since 1992, numerous enhancements and clarification efforts have been made to the generic EAL development guidance resulting in the most recent document, NEI 99-01, Revision 5, "Methodology for Development of Emergency Action Levels," (ADAMS Accession No. ML080450149), which was found to be acceptable for use as generic EAL development guidance by the Nuclear Regulatory Commission (NRC) staff by letter dated . February 22, 2008 (ADAMS Accession No. ML080430535).
The proposed EAL scheme was developed using the generic development guidance from NEI 99-01, Revision 5 with numerous differences and deviations based upon design criteria applicable to the site as well as licensee preferences for terminology, format, and other licensee-desired modifications to the generic EAL scheme development guidance provided in NEI 99-01 Revision 5. Attached are the requests for additional information (RAJ) items to facilitate the technical review being conducted by the Operating Reactor Licensing and Outreach Branch staff. Timely and accurate response to these draft RAls is requested.
Enclosure Section 3.0 of Enclosure 1, "Evaluation of Proposed Change" the last sentence in the last paragraph states that any changes to the approved ICs [initiating conditions) and EALs will be made in accordance with 10 CFR SO.S4(q).
It is the expectation of the staff that changes to the EAL basis information and operating modes will be controlled in the same way as any changes to the approved ICs and EALs. Please explain the rationale for not controlling the EAL Basis Document, as a whole, in accordance with 10 CFR SO.S4(q) or revise this statement accordingly. EAL RU2.2: The use of "offscale high" readings for EAL thresholds is problematic as it is difficult to differentiate between failed instrumentation and actual plant conditions.
Please explain how you will differentiate between the two, in the time allowed, for EAL declaration purposes and how this wording will not result in erroneous declarations, or revise accordingly. EAL RA2: The staff requires further justification for the removal of the level threshold previously approved for EAL RA2.3. The proposed justification for the change is confusing in that it uses a calculation as a basis for the change when in fact there are three unique EAL thresholds expected for this EAL. One is based upon a valid Hi-Rad alarm from 9178, a valid reading> 100 millirem/hr from RM-9178, and indication of lowering fuel pool water level from L1-3413. Redundancy is expected for this EAL due to the significance of the concern and the availability of instrumentation.
Please provide further justification that supports this revision, or revise accordingly. EAL RA3: Please explain why the Secondary Alarm Station is used as a threshold for this EAL as this EAL only requires either the Control Room, and either the Central Alarm Station or Secondary Alarm Station, not both (typically).
Please justify or revise accordingly. EAL CG1: The staff noted an apparent typographical error in the IC. In addition, the staff recommends developing this EAL using the table as provided in the endorsed EAL scheme development guidance as it aids in clarifying the logic for this EAL, however, the staff has no technical opposition to the proposed format and wording. Also, please move the wording " .. .for 30 minutes or longer" from the bulleted list of conditions provided in CG 1.2 to the threshold for "RPV level cannot be monitored." This is a known error in the guidance document which will be corrected in a future revision. EAL EU1: Please provide basis information related to how security events at the ISFSI [independent spent fuel storage installations]
are classified. EAL HU2.1: Note that consideration of"... adjacent areas" was removed as history had shown this to be an area of confusion throughout the nuclear industry and resulted in a delay in classification in some cases. EAL HA 1: Please be aware that the areas of concern are expected to be areas where equipment necessary for safe operation, shutdown, and/or cooldown are located AND where the equipment is at risk from the given hazard. For example, not all areas are susceptible to vehicle crashes, high winds, tornados, or turbine blade failure. Please ensure to consider this when developing the list. 
-EAL HA2: Please provide the list of areas applicable to this EAL. 10. EAL Please revise the list of areas applicable to this EAL to ensure consistent, and accurate, EAL declaration.
Only those areas that contain equipment that must be operated locally for safe operation.
safe shutdown, or safe cooldown should be listed. If an area does not contain equipment that must be operated locally. then consideration for not including this area should be given. Note that the need to operate the equipment is not a threshold, i.e., the impediment to access an area, developed as per the above guidance.
is the expectation for this EAL. Also. consider adding guidance information that allows the decision-maker to use reasonable judgment when considering declaring this EAL. For example, a small CO 2 bottle leaking in a large room/area may not warrant declaration.
Januasy 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785 DUANE ARNOLD ENERGY CENTER -REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (T AC ME6508)  


==Dear Mr. Wells:==
==Dear Mr. Wells:==
By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML 111540279
 
[package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.
The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI) (ADAMS Accession No. ML 12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012. The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAJ. Sincerely, IRA/ Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor licensing Office of Nuclear Reactor Regulation Docket No. 50-331  
The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI)
(ADAMS Accession No. ML12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAJ.
Sincerely, IRA/
Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor licensing Office of Nuclear Reactor Regulation Docket No. 50-331


==Enclosure:==
==Enclosure:==
As stated cc w/encl: Distribution via Listserv DISTRIBUTION:
As stated cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPL3-1 r/f RidsNrrDorlLpl3-1 Resource RidsNrrPMDuaneArnold Resource RidsNrrLABTully Resource RidsAcrsAcnw_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDssStsbirsltsb RidsRgn3MailCenter Resource RidsOgcRp Resource PTam. NRR I I ADAMS ACCESSION No'.-120120318 OFFICE NRRlLPL3-1/PM NRRlLPL3-1/LA NRRlLPL3*1/BC*Acting NRRlLPL3*1/PM NAME KFeintuch BTully SWilliams KFeintuch DATE 01/11/12 01/13/12 01/17/12 01/17/12 OFFICIAL RECORD COpy}}
PUBLIC               LPL3-1 r/f   RidsNrrDorlLpl3-1 Resource             RidsNrrPMDuaneArnold Resource RidsNrrLABTully Resource             RidsAcrsAcnw_MailCTR Resource         RidsNrrDorlDpr Resource RidsNrrDssStsbirsltsb               RidsRgn3MailCenter Resource           RidsOgcRp Resource PTam. NRR ADAMS ACCESSION No'.- 120120318 I
OFFICE     NRRlLPL3-1/PM       NRRlLPL3-1/LA             NRRlLPL3*1/BC*Acting     NRRlLPL3*1/PM NAME       KFeintuch           BTully                   SWilliams                 KFeintuch DATE       01/11/12           01/13/12                 01/17/12                 01/17/12 I
OFFICIAL RECORD COpy}}

Latest revision as of 09:47, 12 November 2019

Request for Additional Information Amendment to Change Emergency Action Levels
ML120120318
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 01/17/2012
From: Feintuch K
Plant Licensing Branch III
To: Wells P
Duane Arnold
Feintuch K
References
TAC ME6508
Download: ML120120318 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785

SUBJECT:

DUANE ARNOLD ENERGY CENTER - REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (TAC ME6508)

Dear Mr. Wells:

By letter dated May 31, 2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.

The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI)

(ADAMS Accession No. ML12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012.

The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources.

Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAt Sincerely, Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-331

Enclosure:

As Stated cc w/encl: Distribution via Listserv

REQUEST FOR ADDITIONAL INFORMATION DUANE ARNOLD ENERGY CENTER LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY PLAN DOCKET NO. 50-331 By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [packageD, NextEra Energy Duane Arnold, LLC requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.

The licensee stated that the license amendment request was for revision of selected EALs and not the entire EAL scheme. However, in effect, the licensee actually submitted their entire EAL scheme and is therefore the scope of this review, i.e., the acceptability of the proposed EAL scheme to meet the standards of 10 CFR 50.47 and the requirements of 10 CFR Appendix E.

In addition, the staff noted numerous changes to the previously approved EAL scheme that were not specifically noted as those requiring prior NRC approval. These changes were also reviewed as part of this license amendment due to the importance of ensuring an acceptable EAL scheme is in place as all offsite actions are predicated on timely and accurate EAL classifications.

DAEC's letter stated that the current DAEC EAL scheme is based on generic development guidance from Nuclear Energy Institute (NEI) document entitled NEI-99-01, "Methodology for Development of Emergency Action Levels," Revision 4, January 2003, (ADAMS Accession No. ML041470143). Since 1992, numerous enhancements and clarification efforts have been made to the generic EAL development guidance resulting in the most recent document, NEI 99-01, Revision 5, "Methodology for Development of Emergency Action Levels," (ADAMS Accession No. ML080450149), which was found to be acceptable for use as generic EAL development guidance by the Nuclear Regulatory Commission (NRC) staff by letter dated

.February 22, 2008 (ADAMS Accession No. ML080430535).

The proposed EAL scheme was developed using the generic development guidance from NEI 99-01, Revision 5 with numerous differences and deviations based upon design criteria applicable to the site as well as licensee preferences for terminology, format, and other licensee-desired modifications to the generic EAL scheme development guidance provided in NEI 99-01 Revision 5.

Attached are the requests for additional information (RAJ) items to facilitate the technical review being conducted by the Operating Reactor Licensing and Outreach Branch staff. Timely and accurate response to these draft RAls is requested.

Enclosure

-2

1. Section 3.0 of Enclosure 1, "Evaluation of Proposed Change" the last sentence in the last paragraph states that any changes to the approved ICs [initiating conditions) and EALs will be made in accordance with 10 CFR SO.S4(q). It is the expectation of the staff that changes to the EAL basis information and operating modes will be controlled in the same way as any changes to the approved ICs and EALs. Please explain the rationale for not controlling the EAL Basis Document, as a whole, in accordance with 10 CFR SO.S4(q) or revise this statement accordingly.
2. EAL RU2.2: The use of "offscale high" readings for EAL thresholds is problematic as it is difficult to differentiate between failed instrumentation and actual plant conditions. Please explain how you will differentiate between the two, in the time allowed, for EAL declaration purposes and how this wording will not result in erroneous declarations, or revise accordingly.
3. EAL RA2: The staff requires further justification for the removal of the level threshold previously approved for EAL RA2.3. The proposed justification for the change is confusing in that it uses a calculation as a basis for the change when in fact there are three unique EAL thresholds expected for this EAL. One is based upon a valid Hi-Rad alarm from RM 9178, a valid reading> 100 millirem/hr from RM-9178, and indication of lowering fuel pool water level from L1-3413. Redundancy is expected for this EAL due to the significance of the concern and the availability of instrumentation. Please provide further justification that supports this revision, or revise accordingly.
4. EAL RA3: Please explain why the Secondary Alarm Station is used as a threshold for this EAL as this EAL only requires either the Control Room, and either the Central Alarm Station or Secondary Alarm Station, not both (typically). Please justify or revise accordingly.

S. EAL CG1: The staff noted an apparent typographical error in the IC. In addition, the staff recommends developing this EAL using the table as provided in the endorsed EAL scheme development guidance as it aids in clarifying the logic for this EAL, however, the staff has no technical opposition to the proposed format and wording. Also, please move the wording

" .. .for 30 minutes or longer" from the bulleted list of conditions provided in CG 1.2 to the threshold for "RPV level cannot be monitored." This is a known error in the guidance document which will be corrected in a future revision.

6. EAL EU1: Please provide basis information related to how security events at the ISFSI

[independent spent fuel storage installations] are classified.

7. EAL HU2.1: Note that consideration of"... adjacent areas" was removed as history had shown this to be an area of confusion throughout the nuclear industry and resulted in a delay in classification in some cases.
8. EAL HA 1: Please be aware that the areas of concern are expected to be areas where equipment necessary for safe operation, shutdown, and/or cooldown are located AND where the equipment is at risk from the given hazard. For example, not all areas are susceptible to vehicle crashes, high winds, tornados, or turbine blade failure. Please ensure to consider this when developing the list.

- 3

9. EAL HA2: Please provide the list of areas applicable to this EAL.
10. EAL HA32: Please revise the list of areas applicable to this EAL to ensure consistent, and accurate, EAL declaration. Only those areas that contain equipment that must be operated locally for safe operation. safe shutdown, or safe cooldown should be listed. If an area does not contain equipment that must be operated locally. then consideration for not including this area should be given. Note that the need to operate the equipment is not a threshold, i.e.,

the impediment to access an area, developed as per the above guidance. is the expectation for this EAL. Also. consider adding guidance information that allows the decision-maker to use reasonable judgment when considering declaring this EAL. For example, a small CO 2 bottle leaking in a large room/area may not warrant declaration.

Januasy 17, 2012 Mr. Peter Wells Vice President Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785

SUBJECT:

DUANE ARNOLD ENERGY CENTER - REQUEST FOR ADDITIONAL INFORMATION RE: AMENDMENT TO CHANGE EMERGENCY ACTION LEVELS (TAC ME6508)

Dear Mr. Wells:

By letter dated May 31,2011 (Agencywide Document Access and Management System (ADAMS) Accession No. ML111540279 [package]), NextEra Energy Duane Arnold, LLC (the licensee) requested an amendment to the operating license for the Duane Arnold Energy Center (DAEC) to revise their emergency plan. Specifically, the licensee requested prior approval for a number of changes to their emergency action levels (EALs), which are actually contained in their emergency plan implementing procedures but are considered an integral part of the DAEC emergency plan and is controlled accordingly.

The NRC staff has determined that it needs additional information to complete its review. On January 4, 2012, the NRC staff transmitted a draft Request for Additional Information (RAI)

(ADAMS Accession No. ML12011A060) and discussed the draft RAI with Mr. Thomas Byrne, a member of your staff in a conference call on January 10, 2012.

The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources Enclosed please find the final RAI items. Your staff agreed that you can provide your response within 30 days of the date of this letter. Please feel free to contact me if you need further clarification of the RAJ.

Sincerely, IRA/

Karl D. Feintuch, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor licensing Office of Nuclear Reactor Regulation Docket No. 50-331

Enclosure:

As stated cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL3-1 r/f RidsNrrDorlLpl3-1 Resource RidsNrrPMDuaneArnold Resource RidsNrrLABTully Resource RidsAcrsAcnw_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDssStsbirsltsb RidsRgn3MailCenter Resource RidsOgcRp Resource PTam. NRR ADAMS ACCESSION No'.- 120120318 I

OFFICE NRRlLPL3-1/PM NRRlLPL3-1/LA NRRlLPL3*1/BC*Acting NRRlLPL3*1/PM NAME KFeintuch BTully SWilliams KFeintuch DATE 01/11/12 01/13/12 01/17/12 01/17/12 I

OFFICIAL RECORD COpy