Line 3: Line 3:
| issue date = 06/19/2017
| issue date = 06/19/2017
| title = Wectec LLC - Interim 10 CFR Part 21 Report Regarding a Reactor Coolant System Pipe Spool for V.C. Summer Unit 3 AP1000 Project
| title = Wectec LLC - Interim 10 CFR Part 21 Report Regarding a Reactor Coolant System Pipe Spool for V.C. Summer Unit 3 AP1000 Project
| author name = Gustafson D A
| author name = Gustafson D
| author affiliation = WECTEC LLC
| author affiliation = WECTEC LLC
| addressee name =  
| addressee name =  
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:., WECTEC June 19, 20 I 7 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 I WECTEC LLC 3735 Glen Lake Drive Charlotte, NC 28208 Tel: +1 980 859 8000 10 CFR 21.21
{{#Wiki_filter:.,
WECTEC LLC WECTEC                                                                          3735 Glen Lake Drive Charlotte, NC 28208 Tel: +1 980 859 8000 10 CFR 21.21 June 19, 20 I 7 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 I


==SUBJECT:==
==SUBJECT:==
 
INTERIM 10 CFR PART 21 REPORT REGARDING A REACTOR COOLANT SYSTEM PIPE SPOOL FOR V. C. SUMMER UNIT 3 APIOOO PROJECT This letter provides an interim report in accordance with* 10 CFR 21.21 pertaining to one reactor coolant system pipe ~pool that is being supplied for V. C. Summer Unit 3 APlOOO project.
INTERIM 10 CFR PART 21 REPORT REGARDING A REACTOR COOLANT SYSTEM PIPE SPOOL FOR V. C. SUMMER UNIT 3 APIOOO PROJECT This letter provides an interim report in accordance with* 10 CFR 21.21 pertaining to one reactor coolant system pipe that is being supplied for V. C. Summer Unit 3 APlOOO project.
Based on information contained in a nonconfonnance & disposition (N&O) report, a weld on a weldolet fitting was found with lack of fusion on the root of the weld.
Based on information contained in a nonconfonnance  
Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017.
& disposition (N&O) report, a weld on a weldolet fitting was found with lack of fusion on the root of the weld. Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017. If you have any questions pertaining to this information, please contact Curtis Castell, Licensing  
If you have any questions pertaining to this information, please contact Curtis Castell, Licensing Manager, at 980-859-6373.
: Manager, at 980-859-6373.
Slncerely,             .,
Slncerely,  
Qlfa. A7J~
. , Qlfa.
Deborah A. Gustafson Vice President Project Services WECTECLLC cc:     Regional Admini:Jtrator, USNRC, Region II}}
Deborah A. Gustafson Vice President Project Services WECTECLLC cc: Regional Admini:Jtrator, USNRC, Region II}}

Latest revision as of 19:36, 29 October 2019

Wectec LLC - Interim 10 CFR Part 21 Report Regarding a Reactor Coolant System Pipe Spool for V.C. Summer Unit 3 AP1000 Project
ML17251A841
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/19/2017
From: Gustafson D
WECTEC LLC
To:
Document Control Desk, Office of New Reactors
References
Download: ML17251A841 (1)


Text

.,

WECTEC LLC WECTEC 3735 Glen Lake Drive Charlotte, NC 28208 Tel: +1 980 859 8000 10 CFR 21.21 June 19, 20 I 7 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 I

SUBJECT:

INTERIM 10 CFR PART 21 REPORT REGARDING A REACTOR COOLANT SYSTEM PIPE SPOOL FOR V. C. SUMMER UNIT 3 APIOOO PROJECT This letter provides an interim report in accordance with* 10 CFR 21.21 pertaining to one reactor coolant system pipe ~pool that is being supplied for V. C. Summer Unit 3 APlOOO project.

Based on information contained in a nonconfonnance & disposition (N&O) report, a weld on a weldolet fitting was found with lack of fusion on the root of the weld.

Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017.

If you have any questions pertaining to this information, please contact Curtis Castell, Licensing Manager, at 980-859-6373.

Slncerely, .,

Qlfa. A7J~

Deborah A. Gustafson Vice President Project Services WECTECLLC cc: Regional Admini:Jtrator, USNRC, Region II