Revision as of 19:29, 13 July 2019

Oak Ridge Institute for Science and Education, Analytical Results for Thirteen Water Samples, Batch Four, from the Vicinity of the Braidwood Nuclear Generating Station, Braidwood, Illinois
ML061290465
Person / Time
Site: Braidwood Constellation icon.png
Issue date: 05/04/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
NRC/RGN-III
References
FOIA/PA-2010-0209, IR-06-003
Download: ML061290465 (4)


Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION May 4, 2006 Mr. William Sncll LIS. Nuclear Regulatory Commission Ikgion 111 2443 Warrenvillc Road I.isle, 11. 60532-4351

SUBJECT:

ANALYTICAL RESULTS FOR THIRTEEN WATER SAMPLES, BATCH FOUR, FROM THE VICINITY OF THE BRAIDWOOD NUCLEAR GENERATING STATION, BRAIDWOOD, ILLINOIS [INSPECTION REPORT NO. 050-00456/2006-0031 (RFTA NO.06-001)

Dear Mr. Snell:

'l'hc Oak Ridge Institute for Science and Education (ORISE) rcccivcd 14 water samples, Batch l;our, on April 25 that were collected in the vicinity of the Braidwood Nuclear Generating Station in Ihidwood, Illinois.

The Request for Analysis form listcd sainplc 1311-06-4-1 1 (ORISIi sample number 1691 W0120) for expedited processing by gamma spectroscopy (GS) and for tritium by liquid scintillation analysis.

'Ihe letter report for this sample was issued on April 28,2006. The remaining samples were analyzed for tritium by liquid scinullation analysis.

One sample was also analyzed by GS as dwected on the Request for Analysis form. 'l'hc sample identifications and collection data are presented in Table 1. 'l'he GS data are presented in Table 2. The tritium data are presented in Table 3. The pertinent procedure rcfcrenccs arc provided in the specific tables. 01IISl:'s Quality Control (QC) requirements were met for these analyses.

'l'he QC files are available for your review upon request. hly contact information is listed below. You may also contact Wade Ivcy at 865.576.9184 with any questions or comments.

Sinccrclv.

I1alc Condra, Manager 1,aboratory R11C:\VPI:db c: ?'. McLaughlin, NRC/NMSS/TWFN 71'27 I:. Abelquist, ORISl< I:. Ihox-Dnvin, NRC/NMSS/TV(IFN 8A23 G. Bonano, NRC Region 111 S. ](irk, ORISI' File 1691 \'oicc: 865.241.3242 Fax: 865241.3248 Ii-mail: CondraD@orau.gov TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS Dru~dwaod Nuclcar Generating Slalion TABLE 2 ORISE NRC Region I11 Sample ID Sample ID 1691 W0114 BD-06-4-05 Radionuclide Concentrations" (pCi/L)

CO-58 CO-60 cs-u4 Cs-137 -0.2 k 5.1~ 0.9 k 5.3 -0.7 ? 5.7 5.0 ? 5.1 Ilraiduood Nuclcar Generating Station projectdl 69IlData 'l'ablesl2006-05-04 I>ata Tahlcr hatch Four TABLE 3 CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS Hraidwood Nuclear Generating Slation projectdl 69l/l>ata

'TablrslZ000-03-04 Data 1-ahlee IMch Four