TAC:47549
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Initiation Results Other: ML13317A118, ML13317A130, ML13317A340, ML13317A420, ML13317A423, ML13317A483, ML13317A615, ML13317A681, ML13317A725, ML13317B114, ML13317B116, ML13333B737, ML14133A353 | |
MONTHYEARML13302B0031981-03-0606 March 1981
[table view]Notification of 810309 Meeting W/Util in Bethesda,Md to Discuss Facility Emergency Plan ML13303A4651981-05-14014 May 1981 Forwards Fes.W/O Encl ML13317A6151981-05-18018 May 1981 Fulfills Commitment Made in Response to NRC 810331 Request Re Vessel Integrity & Responds Further to NRC 810429 Requests & Clarifications Re Reactor Vessel Pressurized Thermal Shock Issue.Discusses Proposed Program ML14133A3531981-05-22022 May 1981 Discusses Commitment to Develop Program Re Potential Reactor Vessel Integrity Concerns Identified in NRC . Program Will Identify Whether Future Addl Plant Specific Analyses &/Or Remedial Actions Will Be Required IR 05000206/19810161981-05-22022 May 1981 IE Insp Rept 50-206/81-16 on 810512-15.No Noncompliance Noted.Major Areas Inspected:Welding Activities Associated W/Mods to Auxiliary Feedwater Sys & Repair of Circumferential Welds on Main Steam Piping ML13317A6591981-06-0202 June 1981 Safety Evaluation Re Environ Qualification of safety-related Electrical Equipment Finding No Outstanding Items That Require Immediate Corrective Action.Deficient Items Replaced.Equipment Qualified for Low Probability Events ML20030A7701981-07-20020 July 1981 Notification of 810728,29 & 30 Meetings W/B&W,Westinghouse & C-E Owners Groups in Bethesda,Md to Discuss Thermal Shock to Reactor Pressure Vessel Issue ML13330A3941981-08-21021 August 1981 Requests Addl Info Re Pressurized Thermal Shock to Reactor Pressure Vessels,Per Review of PWR Owners Group 810515 & Licensees 810522 Responses to NRC IR 05000361/19810171981-08-21021 August 1981 IE Insp Rept 50-361/81-17 on 810715-31.No Noncompliance Noted.Major Areas Inspected:Preoperational Test Program & Procedures,Maint,Plant Tours & Licensee Action on Previously Identified Items ML20031F1401981-10-0101 October 1981 Summary of 810918 Meeting W/Westinghouse Owners Group Re Pressurized Thermal Shock to Reactor Pressure Vessels. Attendance List & Handouts Encl ML13317A6811981-10-0505 October 1981 Responds to Requesting Addl Action Re Pressurized Thermal Shock to Reactor Pressure vessels.Sixty-day Response Schedule Cannot Be Met.Partial Response Will Be Provided by 811104 ML13317A7251981-10-23023 October 1981 Discusses Proposed Response to NRC 810821 Request Re Pressurized Thermal Shock to Reactor Pressure Vessels. Requests Available Portions of Response at Time Provided in ,To Avoid Needless Conservatisms ML13323A2601981-10-31031 October 1981 Operating Instructions for SSH-3/FBA-13 Seismic Scram & Trip Sys ML13317A7201981-11-0404 November 1981 Forwards Partial Response to NRC 810821 Request for Addl Info Re Pressurized Thermal Shock to Reactor Pressure Vessels Per ML13309A0791981-11-0404 November 1981 Forwards Responses to Safety Evaluation of Environ Qualification of safety-related Electrical Equipment,Addl Info Not Addressed in Safety Evaluation & Revised Pages to ML13317A8361982-01-25025 January 1982 Forwards Util 150-day Response to 810821 Request for Addl Info Re Pressurizer Thermal shock.Plant-specific Analyses Indicate That Vessel Integrity Will Be Maintained,Therefore Remedial Actions Not Warranted ML13310A3761982-01-26026 January 1982 Forwards Amend 28 to Fsar,Reissuing Facility Emergency Plan & Offsite Emergency Response Plans (Filed in PDR Category K), & Amend 10 to Fire Hazards Analysis (Filed in Category F) ML13333B8091982-03-0808 March 1982 Summary of 820224 Meeting W/Westinghouse Owners Group, Southern CA Edison,Cp&L & Fl Power & Light in Bethesda,Md Re Pressurized Thermal Shock IR 05000361/19820101982-03-15015 March 1982 IE Insp Rept 50-361/82-10 on 820119-0212.No Noncompliance Noted.Major Areas Inspected:Preoperational Test Program,Tmi Mods,Followup on IE Bulletin 80-06,safety Committee Activities & Independent Insp Effort ML13310A7011982-03-15015 March 1982 Forwards Request for Addl Info Re Pressurized Thermal Shock.Info Should Be Submitted by 820430 ML13317B1141982-04-15015 April 1982 Forwards NRC Staff Audit of Robinson 2 Procedures & Training for Pressurized Thermal Shock, Conducted During 820405-07 Site Visit.Control Room Emergency Procedures Weighted Toward Core Cooling ML13317B1161982-04-15015 April 1982 NRC Staff Audit of Robinson 2 Procedures & Training for Pressurized Thermal Shock ML13317B1111982-04-22022 April 1982 Forwards NRC Task Force on Pressurized Thermal Shock Audit Rept Re Adequacy of Robinson 2 in-plant Training Programs & Operating Procedures.Similar Audit Will Be Performed at San Onofre 1 in Near Future ML13317B1101982-04-27027 April 1982 Advises That Response to NRC 820407 Request for Info Re Emergency Procedures Upgrade Will Be Deferred Until Wk of 820517.Reanalysis of Large Number of Transients Required for plant-specific Guidelines Necessitates Deferral ML13317A1181982-05-0303 May 1982 Advises That Addl Info Requested 820315 for Pressurized Thermal Shock Will Be Provided by 820515 ML13317A1241982-05-26026 May 1982 Forwards Partial Response to 820315 Request for Addl Info Re Pressurized Thermal Shock Issue.Other Responses to Be Included in Westinghouse Owners Group Submittals on 820528 & in June 1982 ML13317A1301982-06-0101 June 1982 Informs That Audit on Pressurized Thermal Shock Will Be Conducted During Wk of 820614,per .Audit Will Review Completion of Revised Operator Training Procedures ML13317A1951982-06-18018 June 1982 Forwards Corrections to 820526 Response to NRC Request for Addl Info Re Pressurized Thermal Shock.Corrected Pages Indicating 14X14 Core Design & Correct Vol Fractions Encl. Changes Do Not Affect Analysis or Conclusions of Submittal ML13333B7371982-07-12012 July 1982 Trip Rept of 820603-04 Site Visit to Evaluate Emergency Procedures & Operator Training Re Pressurized Thermal Shock. Procedures Revised Based on Westinghouse Owners Group Guidelines on plan-specific Analyses ML13317A3401982-09-20020 September 1982 Forwards Rept for 820603-04 Audit of Operator Training & Emergency Procedures Re Pressurized Thermal Shock.Response Addressing Action Being Taken Re Section 5 Recommendations Requested within 45 Days of Ltr Receipt ML13317A4231982-10-15015 October 1982 To Operator Requalification Re Pressurized Thermal Shock ML13317A4201982-11-19019 November 1982 Responds to Recommendations Resulting from Audit Concerning Adequacy of Operator Training & Emergency Procedures Re Pressurized Thermal Shock.Operator Requalification Program Revised to Include More Emphasis on Past Events ML13317A4831983-01-19019 January 1983 Advises That 821119 Response to Audit of Procedures & Training for Pressurized Thermal Shock Acceptable 1982-01-26 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:47549&oldid=5512536"