- GO2-81-147, Potential Deficiency Rept Re Pipe Whip Restraints Inside Containment,Initially Reported on 810129.Deficiency Is Not Reportable.Overall Design Basis Modified + (Potential Deficiency Rept Re Pipe Whip Restraints Inside Containment,Initially Reported on 810129.Deficiency Is Not Reportable.Overall Design Basis Modified)
- ML19318A153 + (Potential Deficiency Rept Re Rockbestos Cable Jacket Extrusion Defects.Jacket Defects Do Not Affect Environ Qualification or Ability of Cable to Perform Intended Function.Defect Does Not Constitute Reportable Deficiency)
- ML20063H498 + (Potential Deficiency Rept Re Worn Polar Crane Snubber Assembly Pin.Initially Reported on 810819.Condition Not Reportable Per 10CFR50.55(e).AE Concluded That Polar Crane Sys Can Resist Seismic Event Generated Impact Loads)
- RIS 2000-25, Potential Deficiency in Qualification of Okonite Single-Conductor Electrical Control Cables + (Potential Deficiency in Qualification of Okonite Single-Conductor Electrical Control Cables)
- Information Notice 1993-33, Potential Deficiency of Certain Class IE Instrumental and Control Cables + (Potential Deficiency of Certain Class IE Instrumental and Control Cables)
- Information Notice 1993-33, Potential Deficiency of Certain Class Ie Instrumental and Control Cables + (Potential Deficiency of Certain Class Ie Instrumental and Control Cables)
- Information Notice 1998-21, Potential Deficiency of Electrical Cable/Connection Systems + (Potential Deficiency of Electrical Cable/Connection Systems)
- Information Notice 1992-81, Potential Deficiency of Electrical Cables with Bonded Hypalon Jackets + (Potential Deficiency of Electrical Cables with Bonded Hypalon Jackets)
- ENS 42953 + (Potential Degradation in the Offsite Emergency Siren Notification System)
- ENS 52244 + (Potential Degradation of Eccs Pump Pressure Indicators)
- Information Notice 2000-12, Potential Degradation of Fire Fighter Primary Protective Garments + (Potential Degradation of Fire Fighter Primary Protective Garments)
- ENS 43071 + (Potential Degradation of Hydraulic Snubber Fluid)
- Information Notice 1996-59, Potential Degradation of Post Loss-of-Coolant Recirculation Capability As a Result of Debris + (Potential Degradation of Post Loss-of-Coolant Recirculation Capability As a Result of Debris)
- Information Notice 1996-59, Potential Degradation of Post Loss-of-Coolant Recirculation Capability as a Result of Debris + (Potential Degradation of Post Loss-of-Coolant Recirculation Capability as a Result of Debris)
- ENS 47884 + (Potential Degradation of Reactor Containment Electrical Penetration Seals)
- 05000266/FIN-2010003-04 + (Potential Degradation of Reactor Protection System P-9 Permissive Operability)
- Information Notice 1990-02, Potential Degradation of Secondary Containment + (Potential Degradation of Secondary Containment)
- ENS 47655 + (Potential Degradation of Technical Support Center Habitability)
- ENS 41783 + (Potential Degraded Condition Due to Pressurizer Heater Element Non-Conformance)
- ML052580399 + (Potential Deliberate Misconduct During Non Licensed Operator Initial Qualification Training)
- ML093020560 + (Potential Delivery of Nonconforming Washers Supplied with Expansion Anchors Type Hilti Kwik Bolt KB3 SS316, 1/4 and 3/8 Diameters, All Lengths, Which May Meet the Definition of a Defect within 10 CFR Part 21)
- ENS 45458 + (Potential Delivery of Nonconforming Washers)
- 05000250/FIN-2015007-02 + (Potential Departure From the Eagle 21 Design Basis)
- ENS 49374 + (Potential Design Basis Flooding Issues Related to Battery Room Wall Penetrations and Cable Vault Floor Drains)
- 05000456/FIN-2011003-05 + (Potential Design Control Violation Related to Safety-Related Door Impairment)
- Information Notice 2013-14, Potential Design Deficiency In Motor-Operated Valve Control Circuitry + (Potential Design Deficiency In Motor-Operated Valve Control Circuitry)
- Information Notice 2013-14, Potential Design Deficiency in Motor-Operated Valve Control Circuitry + (Potential Design Deficiency in Motor-Operated Valve Control Circuitry)
- ENS 46759 + (Potential Deviation in Seismic Ratings of Abb, Inc. Kf Relay Family)
- ENS 43379 + (Potential Division 1 Edg Damage Due to Loss of Service Water Cooling During Control Room Fire)
- ENS 45250 + (Potential Dose to Wrong Site)
- Information Notice 1985-47, Potential Effect of Line-Induced Vibration on Certain Target Rock Solenoid-Operated Valves + (Potential Effect of Line-Induced Vibration on Certain Target Rock Solenoid-Operated Valves)
- ML20128L407 + (Potential Effects of Contichem-Proposed Residual Soil Criteria on Water Quality of Indian Kill Reservoir)
- 05000348/FIN-2014007-07 + (Potential Effects of an RCP Thermal Barrier Break to the CCW System Were Not Evaluated)
- Information Notice 1989-03, Potential Electrical Equipment Problems + (Potential Electrical Equipment Problems)
- ENS 46598 + (Potential Emergency Diesel Generator Bearing Failures)
- ML20214A187 + (Potential Enforcement Finding from Insp on 860915-19 & 0929- 1003)
- Information Notice 1990-28, Potential Error In High Steamline Flow Setpoint + (Potential Error In High Steamline Flow Setpoint)
- Information Notice 1990-28, Potential Error in High Steamline Flow Setpoint + (Potential Error in High Steamline Flow Setpoint)
- Information Notice 1994-65, Potential Errors in Manual Brachytherapy Dose Calculations Generated Using a Computerized Treatment Planning System + (Potential Errors in Manual Brachytherapy Dose Calculations Generated Using a Computerized Treatment Planning System)
- 05000255/FIN-2012002-01 + (Potential Exam Compromise During Requalification Exam)
- 05000255/FIN-2012002-02 + (Potential Exam Compromise During Requalification Exam)
- ENS 49217 + (Potential Existence of Defects in Shield Passive Thermal Shutdown Seal System)
- ENS 46340 + (Potential External Leakage in Solenoid Valve)
- ENS 42087 + (Potential Extremety Dose in Excess of 250 Rad)
- ENS 43108 + (Potential Extremity Dose in Excess of 50 Rem)
- ENS 57696 + (Potential Extremity Overexposure)
- ENS 42424 + (Potential Extremity Overexposure at Texas A&M Research Reactor Per 10Cfr20.2202(B)(1)(Iii))
- 05000321/LER-1979-081-01, Potential Failure Mode for Several Primary Containment Purge & Inerting Valves Discovered by Ae & Valve Vendor.During Loca,Valves Could Over Travel & Lose Seating Capability + (Potential Failure Mode for Several Primary Containment Purge & Inerting Valves Discovered by Ae & Valve Vendor.During Loca,Valves Could Over Travel & Lose Seating Capability)
- Information Notice 2007-07, Potential Failure of All Control Rod Groups to Insert in a Boiling Water Reactor (BWR) Due to a Fire + (Potential Failure of All Control Rod Groups to Insert in a Boiling Water Reactor (BWR) Due to a Fire)
- Information Notice 1986-70, Potential Failure of All Emergency Diesel Generators + (Potential Failure of All Emergency Diesel Generators)
- Information Notice 1989-29, Potential Failure of Asea Brown Boveri Circuit Breakers During Seismic Event + (Potential Failure of Asea Brown Boveri Circuit Breakers During Seismic Event)