Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20203N674 + (02:01:41, 8 December 2024)
- ML20203N677 + (02:01:41, 8 December 2024)
- ML20203N673 + (02:01:42, 8 December 2024)
- ML20203N669 + (02:01:43, 8 December 2024)
- ML20203N670 + (02:01:43, 8 December 2024)
- ML20203N668 + (02:01:44, 8 December 2024)
- ML20203N667 + (02:01:45, 8 December 2024)
- ML20203N665 + (02:01:46, 8 December 2024)
- ML20203N662 + (02:01:47, 8 December 2024)
- ML20203N661 + (02:01:47, 8 December 2024)
- ML20203N660 + (02:01:48, 8 December 2024)
- ML20203N657 + (02:01:49, 8 December 2024)
- ML20203N656 + (02:01:50, 8 December 2024)
- ML20203N655 + (02:01:51, 8 December 2024)
- ML20203N654 + (02:01:52, 8 December 2024)
- ML20203N653 + (02:01:53, 8 December 2024)
- ML20203N651 + (02:01:57, 8 December 2024)
- ML20203N648 + (02:02:01, 8 December 2024)
- ML20203N646 + (02:02:02, 8 December 2024)
- ML20203N647 + (02:02:02, 8 December 2024)
- IR 05000348/1986006 + (02:02:03, 8 December 2024)
- ML20203N642 + (02:02:20, 8 December 2024)
- ML20203N641 + (02:02:21, 8 December 2024)
- ML20203N638 + (02:02:22, 8 December 2024)
- ML20203N637 + (02:02:22, 8 December 2024)
- ML20203N636 + (02:02:23, 8 December 2024)
- ML20203N632 + (02:02:24, 8 December 2024)
- ML20203N631 + (02:02:24, 8 December 2024)
- PNO-V-86-067, on 861001,fuel Assembly in Vessel Found W/ 10-degree Tilt & Resting Askew Against Core Baffle Plate. Cause Under Investigation.Program & Special Tools Prepared to Return Assembly to Vertical Position + (02:02:25, 8 December 2024)
- ML20203N627 + (02:02:26, 8 December 2024)
- 05000440/LER-1986-057, :on 860903,containment Isolation Valves Not Deactivated in Closed Position.Caused by Failure of Nonconformance Rept Program to Require Routing of Environ Qualification Deficiencies to Control Room.Program Revised + (02:02:27, 8 December 2024)
- 3F1086-01, Declines to Fulfill NRC 860919 Request for Meteorological Data,Per IE Info Notice 84-91.Data of Questionable Use in Evaluating Adequacy of Data Collection Program.Util Meteorological Measurements Program Adequate + (02:02:28, 8 December 2024)
- IR 05000424/1986025 + (02:02:29, 8 December 2024)
- 05000440/LER-1986-056, :on 860902 & 29,RWCU Containment Isolations Occurred.Caused by Flow Control Valve Problems,Placement of Blowdown Flow Element & Insufficient Operating Instructions. Design Changes Initiated.Instructions Will Be Revised + (02:02:31, 8 December 2024)
- ML20203N620 + (02:02:32, 8 December 2024)
- 05000482/LER-1986-047, :on 860904,waste Gas Decay Tank 8 Found Slowly Decreasing in Pressure During Planned Release from Tank 2. Caused by Leak Into Tank 2 Via Drain Connections W/Common Header.Drain Valve Repaired + (02:02:34, 8 December 2024)
- ML20203N616 + (02:02:35, 8 December 2024)
- 05000440/LER-1986-055, :on 860902,reactor Scram Occurred.Caused by Sudden Increase in Sensed Pressure for Steam Bypass Valves Controller.Pressure Regulators & Instrumentation Valve Lineups Recalibr,Procedures Revised & Mgt Directive Issued + (02:02:37, 8 December 2024)
- ML20203N613 + (02:02:38, 8 December 2024)
- ML20203N611 + (02:02:39, 8 December 2024)
- ML20203N610 + (02:02:39, 8 December 2024)
- 05000254/LER-1986-027-02, :on 860905,RCIC Pump Discharge to Reactor Vessel Valve 1-1301-48 Failed to Open.Caused by High Pickup Voltage on 250-volt Dc Motor Operated Valve Contactor. Voltage Changed & Valve Cycled Successfully + (02:02:41, 8 December 2024)
- ML20203N608 + (02:02:42, 8 December 2024)
- 05000440/LER-1986-054, :on 860902,07,11,13,15 & 19,RCIC Isolations Occurred.Caused by Instrument Isolation Valve Failure & Impulse Line Slope Problems,Leak Detection Response Time & Personnel Error.Valves Repaired or Replaced + (02:02:44, 8 December 2024)
- ML20203N605 + (02:02:45, 8 December 2024)
- ML20203N604 + (02:02:46, 8 December 2024)
- ML20203N601 + (02:02:47, 8 December 2024)
- ML20203N600 + (02:02:48, 8 December 2024)
- 05000341/LER-1986-027, :on 860831,valve Closed & Could Not Be Reopened During Monthly Operability Check.Caused by Equipment Failure Due to Corrosion.Corroded Disc & Shaft Replaced W/Stainless Steel Components + (02:02:50, 8 December 2024)
- 05000440/LER-1986-053, :on 860901,containment & Drywell Vacuum Breakers Discovered Open.Caused by Procedural Error. Integrated Operating Instruction for Cold Startup Revised. Control Room Operators Counseled + (02:02:52, 8 December 2024)
- ML20203N596 + (02:02:53, 8 December 2024)