Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000313/1975011 + (13:56:10, 31 December 2024)
- ML19326B452 + (13:56:20, 31 December 2024)
- 05000313/LER-1977-027-03, /03L-0:on 771203,weld in Vent Line to Valve DH-1010 Leaked.Caused by vibration.Three-quarter Inch Half Coupling & Vent Valve Replaced w/2 by 3 Inch Sockolet & Plug,Eliminating Valve DH-1010 + (13:56:22, 31 December 2024)
- 05000313/LER-1977-025-03, /03L-0:on 771129,during Insp,Snubber Fluid Reservoir for PSV-1000 Found Empty W/Cracked Wiper Ring. Caused by Ring Matl.New Ring & Gaskets Made of Ethylene Propylene Installed + (13:56:23, 31 December 2024)
- ML19326B449 + (13:56:24, 31 December 2024)
- ML19326B447 + (13:56:25, 31 December 2024)
- ML19326B442 + (13:56:26, 31 December 2024)
- 05000313/LER-1977-026-03, /03L-0:on 771203,reactor Coolant Pump Seal Pressure Dropped & Leakage Occurred.Caused by Wear Due to Startups & Shutdowns.All Pump Seals Replaced + (13:56:27, 31 December 2024)
- ML19326B439 + (13:56:28, 31 December 2024)
- IR 05000313/1977021 + (13:56:30, 31 December 2024)
- ML19326B435 + (13:56:31, 31 December 2024)
- ML19326B434 + (13:56:32, 31 December 2024)
- 05000313/LER-1978-022-03, /03L-0:on 780820,fluid in Hydraulic Shock Suppressor Did Not Cover Supply Line to Valve Body.Caused by Incorrect Suppressor Installation.Suppressor re-oriented + (13:56:33, 31 December 2024)
- ML19326B432 + (13:56:34, 31 December 2024)
- ML19326B430 + (13:56:35, 31 December 2024)
- 05000313/LER-1978-021-03, /03L-0:on 780818,leak Found in B Reactor Coolant Pump Area.Caused by High Pressure Seal Cavity Pressure Sensing Line Leak.Leak to Be Repaired in Next Shutdown + (13:56:37, 31 December 2024)
- IR 05000397/2019405 + (13:56:38, 31 December 2024)
- ML19326B427 + (13:56:38, 31 December 2024)
- ML19326B426 + (13:56:39, 31 December 2024)
- 05000313/LER-1978-020-03, /03L-0:on 780817,solenoid Valve SV 7807,supplying Control Air to VSF-9 Discharge Damper,Failed.Caused by Valve Defect.Valve Replaced + (13:56:41, 31 December 2024)
- ML19326B423 + (13:56:42, 31 December 2024)
- ML19326B422 + (13:56:42, 31 December 2024)
- ML19326B418 + (13:56:43, 31 December 2024)
- ML19326B416 + (13:56:44, 31 December 2024)
- ML19326B417 + (13:56:44, 31 December 2024)
- ML19326B414 + (13:56:45, 31 December 2024)
- ML19326B412 + (13:56:46, 31 December 2024)
- ML19326B411 + (13:56:46, 31 December 2024)
- ML19326B410 + (13:56:47, 31 December 2024)
- ML19326B409 + (13:56:47, 31 December 2024)
- ML19326B407 + (13:56:48, 31 December 2024)
- ML19326B406 + (13:56:48, 31 December 2024)
- ML19326B403 + (13:56:49, 31 December 2024)
- ML19326B404 + (13:56:49, 31 December 2024)
- 05000313/LER-1978-009-01, /01T-0:on 780413,B&W Advised Util That Results of 0.04 Ft Squared RCS Pump Discharge Break Analysis Unacceptable.Caused by ECCS Analysis re-evaluation Performed for Newer B&W Plants + (13:56:51, 31 December 2024)
- ML19326B401 + (13:56:52, 31 December 2024)
- ML19326B400 + (13:56:52, 31 December 2024)
- ML19326B398 + (13:56:53, 31 December 2024)
- 05000313/LER-1978-009, Forwards LER 78-009/01T-0 + (13:56:54, 31 December 2024)
- ML19326B394 + (13:56:55, 31 December 2024)
- 05000313/LER-1978-011-03, /03L-0:on 780420,exhaust Fan VEF-37B Supply Breaker Tripped.Cause Unknown.Circuit Breaker & Overload Heater Replaced + (13:56:56, 31 December 2024)
- ML19326B392 + (13:56:58, 31 December 2024)
- ML19326B391 + (13:56:58, 31 December 2024)
- 05000313/LER-1978-010-03, /03L-0:on 780419,motor Operator of Standby Hydrogen Purge Isolation Valve CV-7449 Failed to Torque Out. Caused by Torque Switch Failure.Switch Replaced + (13:56:59, 31 December 2024)
- ML19326B389 + (13:57:05, 31 December 2024)
- ML19326B388 + (13:57:05, 31 December 2024)
- ML19326B386 + (13:57:06, 31 December 2024)
- ML19326B384 + (13:57:07, 31 December 2024)
- 05000313/LER-1978-013-03, /03L-0:on 780426,emergency Supply Fan VSF9 Failed to Start Automatically During Radiation Monitor RE-8001 Testing.Caused by Defective Actuating Solenoid.Solenoid Repaired + (13:57:09, 31 December 2024)
- ML19326B381 + (13:57:10, 31 December 2024)
- 05000313/LER-1978-013, Forwards LER 78-013/03L-0 + (13:57:11, 31 December 2024)