- ML19260C165 + (18:30:22, 3 January 2025)
- ML19260C163 + (18:30:24, 3 January 2025)
- ML19260C162 + (18:30:32, 3 January 2025)
- 05000277/LER-1979-052-01, /01T-0:on 791127,analysis Per IE Info Notice 79-28 Revealed Four Concrete Expansion Bolts in Concrete Block Walls W/Safety Factors of Less than Four.Caused by Deficient Design.Corrective Actions to Be Completed by 800101 + (18:31:03, 3 January 2025)
- 05000277/LER-1979-052, Forwards LER 79-052/01T-0 + (18:31:44, 3 January 2025)
- 05000366/LER-1979-125-03, /03L-0:on 791114,during Routine Review of Previous Radwaste Discharges,Discovered That on 791107,while at O Mwt Power,Min Required Recirculation Time Not Met on Chemical Waste Sample Tank A.Caused by Clogged Inlet Strainer + (18:32:03, 3 January 2025)
- 05000334/LER-1979-046-01, /01T-0:on 791127,while Generator Which Provides Emergency Power to Motor Operated Valve CH-115D Was Removed from Svc,Valve Was Placed on Clearance in Closed Position for Maint.Caused by Operator Error + (18:32:08, 3 January 2025)
- 05000293/LER-1979-041-04, /04T-1:on 791119,util Notified by Lab That Quarterly Composite Sample of Air Particulates Taken at Overlook Contained Co-60 in Excess of Tech Specs.Caused by Improved Analytical Techniques Sensitive to More Isotopes + (18:32:12, 3 January 2025)
- 05000366/LER-1979-125, Forwards LER 79-125/03L-0 + (18:32:15, 3 January 2025)
- 05000334/LER-1979-046, Forwards LER 79-046/01T-0 + (18:32:19, 3 January 2025)
- ML19260C148 + (18:32:22, 3 January 2025)
- 05000293/LER-1979-041, Forwards LER 79-041/04T-1 + (18:32:54, 3 January 2025)
- 05000259/LER-1979-031-03, /03L-0:on 791112,drywell Air Sampling Monitor,Rm 90-256,observed Alarming Downscale.Erratic Indications Recorded on Previous Occasions.Caused by Failure of Raeco Model 1017 24-Volt Transformer.Transformer Replaced + (18:33:09, 3 January 2025)
- ML19260C143 + (18:33:11, 3 January 2025)
- ML19260C142 + (18:33:13, 3 January 2025)
- 05000259/LER-1979-032-01, /01T-0:on 791128,residual Heat Removal Supply to D Heat Exchanger Restraint R16 Determined Nonfunctional as Installed.Caused by Erroneous Application of Typical Hanger Design.Sys Will Function During Seismic Event + (18:33:16, 3 January 2025)
- 05000259/LER-1979-031, Forwards LER 79-031/03L-0 + (18:33:23, 3 January 2025)
- ML19260C138 + (18:33:25, 3 January 2025)
- 05000317/LER-1979-068-03, /03L-0:on 791127,during Normal Steady State Operation,Emergency Diesel Generator Placed Out of Svc. Caused by Need to Replace Hoffman Air Vent Float Valve Which Failed Due to Normal Wear + (18:33:28, 3 January 2025)
- ML19260C136 + (18:33:30, 3 January 2025)
- 05000259/LER-1979-032, Forwards LER 79-032/01T-0 + (18:34:04, 3 January 2025)
- 05000325/LER-1979-099-03, /03L-0:on 791115,during Normal Reactor Startup, Full in Lights Remained Lit on Control Rods 18-11 & 26-11 When Rods Removed from Full in Position.Caused by Short & Defective Gate on Buffer Probe Cards + (18:34:38, 3 January 2025)
- ML19260C130 + (18:34:41, 3 January 2025)
- ML19260C129 + (18:34:43, 3 January 2025)
- 05000317/LER-1979-068, Forwards LER 79-068/03L-0 + (18:34:46, 3 January 2025)
- ML19260C126 + (18:34:49, 3 January 2025)
- ML19260C125 + (18:34:50, 3 January 2025)
- ML19260C124 + (18:34:52, 3 January 2025)
- 05000325/LER-1979-099, Forwards LER 79-099/03L-0 + (18:35:01, 3 January 2025)
- 05000336/LER-1979-037-31, /03L-0:on 791114 During Routine Maint,Leakage Discovered on Boric Acid Evaporator B Concentrates Pump Discharge Line,Due to Hairline Crack in Type 304 Stainless Steel Pipe.Caused by Chloride Stress Corrosion Cracking + (18:35:06, 3 January 2025)
- 05000333/LER-1979-105-03, /03L-0:on 791114,during Normal Operation,Noisy Lubricating Oil Recirculating Pump Associated W/Emergency Diesel Generator C Noted.Caused by Bad Bearing in Pump Motor.Motor Replaced + (18:35:10, 3 January 2025)
- 05000333/LER-1979-105, Forwards LER 79-105/03L-0 + (18:35:14, 3 January 2025)
- 05000336/LER-1979-037, Forwards LER 79-037/03L-0 + (18:35:18, 3 January 2025)
- ML19260C115 + (18:35:20, 3 January 2025)
- 05000336/LER-1979-038-03, /03L-0:on 791113,leakage Discovered on Aerated Radwaste Drain Line.Caused by Wall Pitting or Cracking. Failed Pipe Section Will Be Replaced When Matl Is Available & Further Investigation Will Be Conducted + (18:35:23, 3 January 2025)
- 05000336/LER-1979-038, Forwards LER 79-038/03L-0 + (18:35:26, 3 January 2025)
- ML19260C110 + (18:35:29, 3 January 2025)
- ML19260C109 + (18:35:30, 3 January 2025)
- 05000338/LER-1979-146-03, /03L-0:on 791116,w/unit in Refueling Shutdown, Pressurizer Level Protection Channel III Found to Be Reading Erratic & Inconsistent W/Actual Level.Caused by Defective Module Amplifier in Transmitter LT-1461 + (18:35:32, 3 January 2025)
- ML19260C107 + (18:35:34, 3 January 2025)
- 05000338/LER-1979-146, Forwards LER 79-146/03L-0 + (18:35:36, 3 January 2025)
- ML19260C104 + (18:35:38, 3 January 2025)
- ML19260C102 + (18:35:39, 3 January 2025)
- 05000309/LER-1979-029-99, /99X-0:on 791025,during Routine Shutdown Operations for Repair of Leaking Valve,Reactor Coolant Dose Equivalent Iodine Exceeded Tech Specs.Caused by Minor Fuel Cladding Degradation + (18:35:42, 3 January 2025)
- 05000309/LER-1979-029, Forwards LER 79-029/99X-0 + (18:35:48, 3 January 2025)
- 05000325/LER-1979-086-03, /03L-0:on 791119,during Normal Operation, Containment Atmospheric Monitor CAC-AQH-1263 Failed Downscale on Oxygen Channel.Cause Unknown.Instrument Recalibr.Investigating Other Monitoring Sys + (18:35:52, 3 January 2025)
- ML19260C097 + (18:35:54, 3 January 2025)
- 05000325/LER-1979-086, Forwards LER 79-086/03L-0 + (18:35:56, 3 January 2025)
- ML19260C094 + (18:35:58, 3 January 2025)
- 05000325/LER-1979-094-03, /03L-0:on 791116,during Normal Operation,Broken Drive Belt Was Found on Containment Atmospheric Monitor CAC-AQH-1259.Caused by Normal Wear.Belt Added to Periodic Maint Program to Detect Worn Belts in Future + (18:36:01, 3 January 2025)
- ML19260C092 + (18:36:03, 3 January 2025)