- 05000321/LER-1979-104-03, /03L-0:on 791216,w/reactor in Shutdown Mode, Standby Diesel Svc Water Pump Motor 2P41-C002 Tripped.Caused by Mechanical Overload.Bolts Associated W/Pump Had Broken Loose Causing Misalignment of Pump Shaft.Pump Rebuilt + (18:04:03, 3 January 2025)
- ML19260C746 + (18:04:22, 3 January 2025)
- 05000321/LER-1979-104, Forwards LER 79-104/03L-0 + (18:05:06, 3 January 2025)
- ML19260C743 + (18:05:34, 3 January 2025)
- ML19260C742 + (18:05:37, 3 January 2025)
- ML19260C740 + (18:05:40, 3 January 2025)
- 05000271/LER-1979-032-03, /03L-0:on 791204,Seismic Class I Hanger CST-HD19B Found to Be Damaged & Inoperable During Review Per IE Bulletin 79-02.Cause Under Investigation.Hanger Replaced & Design Changes Are Being Tested + (18:07:44, 3 January 2025)
- 05000271/LER-1979-032, Forwards LER 79-032/03L-0 + (18:08:12, 3 January 2025)
- ML19260C736 + (18:08:20, 3 January 2025)
- ML19260C735 + (18:08:30, 3 January 2025)
- 05000321/LER-1979-101-03, /03L-0:on 791212 & 13,w/reactor in Run Mode & on 791216,w/reactor in Cold Shutdown,Diesel Generator C Failed to Start.Apparently Caused by Particles of Rust in Governor Booster Servo.Servo Cleaned & Reinstalled + (18:08:34, 3 January 2025)
- ML19260C733 + (18:08:37, 3 January 2025)
- ML19260C731 + (18:08:37, 3 January 2025)
- ML19260C730 + (18:08:38, 3 January 2025)
- 05000321/LER-1979-101, Forwards LER 79-101/03L-0 + (18:08:42, 3 January 2025)
- ML19260C726 + (18:08:51, 3 January 2025)
- ML19260C725 + (18:08:52, 3 January 2025)
- 05000324/LER-1979-088-03, /03L-0:on 791206 & 13,reactor Recirculation Pump 2B Tripped.Possibly Caused by Short Brushes on Exciter Collector Rings Causing Degraded Excitation for Generator Field Which Forced Voltage Regulator Fuses to Blow + (18:08:55, 3 January 2025)
- ML19260C722 + (18:08:57, 3 January 2025)
- ML19260C721 + (18:08:59, 3 January 2025)
- 05000324/LER-1979-088, Forwards LER 79-088/03L-0 + (18:09:03, 3 January 2025)
- ML19260C718 + (18:09:12, 3 January 2025)
- ML19260C717 + (18:09:13, 3 January 2025)
- 05000333/LER-1979-114-04, /04T-0:on 791221,environ Radiological Monitoring Sample Indicated Co-60 Concentration of Onsite Nmpp Location as Being Ten Times Value of Control Station Sample. Caused by Possible Concentration of Trace Metals + (18:09:18, 3 January 2025)
- ML19260C715 + (18:09:21, 3 January 2025)
- ML19260C714 + (18:09:22, 3 January 2025)
- 05000336/LER-1979-039-03, /03L-0:on 791128,while Shut Down for Repair of Feedwater Sys Nozzles,Maint Was Performed W/O Local Leak Rate Test,Therefore Leakage Rate Not Confirmed.Cause Not Stated.Administrative Procedures Mod + (18:09:26, 3 January 2025)
- ML19260C712 + (18:09:49, 3 January 2025)
- 05000333/LER-1979-114, Forwards LER 79-114/04T-0 + (18:10:28, 3 January 2025)
- ML19260C709 + (18:10:32, 3 January 2025)
- 05000336/LER-1979-039, Forwards LER 79-039/03L-0 + (18:10:37, 3 January 2025)
- 05000267/LER-1979-064-03, /03L-0:on 791205,during Surveillance Test on Class 1 Hydraulic Snubbers,Three Snubbers Found Inoperable & Two Installed W/Incorrect Orientation.Caused by Piston Ring Being Out of Tolerance on One Snubber + (18:10:41, 3 January 2025)
- ML19260C704 + (18:10:44, 3 January 2025)
- 05000267/LER-1979-064, Forwards LER 79-064/03L-0 + (18:10:47, 3 January 2025)
- ML19260C701 + (18:10:50, 3 January 2025)
- ML19260C699 + (18:10:58, 3 January 2025)
- ML19260C697 + (18:11:07, 3 January 2025)
- ML19260C696 + (18:11:15, 3 January 2025)
- ML19260C694 + (18:11:32, 3 January 2025)
- 05000325/LER-1979-104-03, /03L-0:on 791206,during Flow Rate Test,Hpci Sys Isolated Due to High Suction Pressure Signal from 1E41-PDH- N031.Caused by Leaking Diaphragm Providing False Signal. Diaphragm Replaced & Returned to Svc + (18:11:38, 3 January 2025)
- ML19260C692 + (18:11:47, 3 January 2025)
- 05000325/LER-1979-104, Forwards LER 79-104/03L-0 + (18:11:52, 3 January 2025)
- TAC:08493 + (18:13:01, 3 January 2025)
- ML19260C689 + (18:13:05, 3 January 2025)
- 05000325/LER-1979-101-03, /03L-0:on 791205,during HPCI Exhaust Diaphram High Pressure Calibr,Switch 1E41-PS-NO12A Would Not Actuate at Any Applied Pressure Up to 30 Psig.Caused by Intermittent Actuation of Internal Micro Switch.Switch Replaced + (18:13:10, 3 January 2025)
- 05000325/LER-1979-101, Forwards LER 79-101/03L-0 + (18:13:15, 3 January 2025)
- ML19260C685 + (18:13:19, 3 January 2025)
- ML19260C684 + (18:13:22, 3 January 2025)