Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19339B978 + (17:13:53, 25 December 2024)
- ML19339B977 + (17:13:54, 25 December 2024)
- ML19339B976 + (17:13:56, 25 December 2024)
- ML19339B974 + (17:13:58, 25 December 2024)
- ML19339B973 + (17:14:04, 25 December 2024)
- ML19339B971 + (17:14:09, 25 December 2024)
- ML19339B970 + (17:14:10, 25 December 2024)
- ML19339B968 + (17:14:12, 25 December 2024)
- ML19339B965 + (17:14:13, 25 December 2024)
- ML19339B964 + (17:14:15, 25 December 2024)
- ML19339B963 + (17:16:13, 25 December 2024)
- ML19339B962 + (17:16:17, 25 December 2024)
- 05000339/LER-1980-068-03, /03L-0:on 801004,summing Amp Card Was Discovered Out of Cal.Caused by Procedural Inadequacy Resulting in Undetected Setpoint Drift.Summing Amps Recalibr + (17:16:51, 25 December 2024)
- ML19339B960 + (17:16:56, 25 December 2024)
- 05000339/LER-1980-068, Forwards LER 80-068/03L-0 + (17:18:15, 25 December 2024)
- ML19339B956 + (17:18:17, 25 December 2024)
- ML19339B955 + (17:18:20, 25 December 2024)
- 05000266/LER-1980-012-03, /03L-0:on 801005,logs Showed Decrease in Holdup Tank Pressure During 801002-05.Evaluation Showed Leak on Compression Fitting on Inlet to Valve IPCV-1022C.Caused by Improper Reinstallation of Valve After Cleaning + (17:18:27, 25 December 2024)
- 05000266/LER-1980-012, Forwards LER 80-012/03L-0 + (17:18:34, 25 December 2024)
- 05000029/LER-1980-017-03, /03L-0:on 801006,during Maint Outage While Performing Calibr of Steam Generator 2,low Steam Generator Water Trip Setpoint Was Found Operating Below Tech Spec Limits.Caused by Sensing Line Configuration Deficiency + (17:18:44, 25 December 2024)
- ML19339B947 + (17:18:49, 25 December 2024)
- 05000029/LER-1980-017, Forwards LER 80-017/03L-0 + (17:18:52, 25 December 2024)
- ML19339B944 + (17:18:56, 25 December 2024)
- 05000325/LER-1980-078-03, /03L-0:on 801007,while Verifying Rod Positions, Control Rod 30-35 Had No Full Out Indication.Caused by Defective Rod Position Indication Reed Switch.Repair Set for Next Long Outage.Work Request Re Generic Problem Written + (17:18:59, 25 December 2024)
- 05000325/LER-1980-078, Forwards LER 80-078/03L-0 + (17:19:02, 25 December 2024)
- B10114, Submits Addl Info Re Automatic Surveillance Testing of Coincident Logic Circuits Associated W/Engineered Safety Features Actuation Sys,To Support 761227 Application for Proposed Tech Specs + (17:19:05, 25 December 2024)
- ML19339B939 + (17:19:08, 25 December 2024)
- 05000324/LER-1980-074-03, /03L-1:on 800927,primary Containment Oxygen Concentration Exceeded 4% for One Hour.Caused by Insufficient Nitrogen for Initial Inerting.Nitrogen Added to Primary Containment & Personnel Counseled + (17:19:11, 25 December 2024)
- ML19339B936 + (17:19:12, 25 December 2024)
- 05000324/LER-1980-074, Forwards LER 80-074/03L-1 + (17:19:14, 25 December 2024)
- ML19339B933 + (17:19:15, 25 December 2024)
- 05000293/LER-1980-061-03, /03X-1:on 800825,surveillance Testing,Initiated Because of HPCI Sys Failure,Determined That a Loop of Core Spray Sys Was Inoperable.Caused by Core Spray Valve Mo 1400-24A Being Partially Stuck Open + (17:19:17, 25 December 2024)
- 05000293/LER-1980-061, Forwards LER 80-061/03X-1 + (17:19:21, 25 December 2024)
- 05000318/LER-1980-058, Forwards LER 80-058/01T-1 + (17:19:33, 25 December 2024)
- ML19339B927 + (17:19:37, 25 December 2024)
- ML19339B926 + (17:19:40, 25 December 2024)
- 05000368/LER-1980-073-03, /03L-0:on 801002,fire Monitoring Instrumentation, Transformer 2X11,shorted Out.Caused by Tie Wire Which Was Being Discarded.Winding Lug Replaced + (17:19:44, 25 December 2024)
- 05000368/LER-1980-073, Forwards LER 80-073/03L-0 + (17:19:48, 25 December 2024)
- 05000368/LER-1980-074-03, /03L-0:on 801004,steam Generator Level Indicator 2LI-1031-2 Failed Acceptance Criteria Per Surveillance Test. Caused by Indicating Needle Occasionally Sticking.Needle Adjusted & Calibr Performed + (17:19:51, 25 December 2024)
- 05000368/LER-1980-074, Forwards LER 80-074/03L-0 + (17:19:55, 25 December 2024)
- 05000265/LER-1980-024-03, /03L-0:on 801010,valve MO-2-1-1001-34A Would Only Open Far Enough to Give Dual Position Indication.Caused by Limit Switches on Valve Operator Being Out of Adjustment. Limit Switches Adjusted & Control Switch Cleaned + (17:19:58, 25 December 2024)
- 05000265/LER-1980-024, Forwards LER 80-024/03L-0 + (17:20:01, 25 December 2024)
- 05000339/LER-1980-072-03, /03L-0:on 801008 & 20,boron Injection Tank & Boric Acid Storage Tank Were Sampled & Found to Contain Boron Concentration Below Tech Spec Limit.Caused by Leakage Past Water Shutoff Valve.Valves Readjusted + (17:20:04, 25 December 2024)
- 05000339/LER-1980-072, Forwards LER 80-072/03L-0 + (17:20:06, 25 December 2024)
- AECM-80-265, Requests 60-day Extension So GE May Complete Evaluation of NSSS Portions of Station Affected by IE Bulletin 80-16. Partial Response Submitted on 800827 + (17:20:08, 25 December 2024)
- 05000295/LER-1980-043-03, /03L-0:on 801001,while Testing Charcoal Filter Banks OAVO40 & OAVO41,found Filter Banks 95% Below Required Tech Specs.Caused by Change in Tech Specs.Charcoal Filters Replaced + (17:20:31, 25 December 2024)
- ML19339B910 + (17:20:33, 25 December 2024)
- ML19339B909 + (17:20:34, 25 December 2024)
- ML19339B908 + (17:20:35, 25 December 2024)
- 05000295/LER-1980-043, Forwards LER 80-043/03L-0 + (17:20:37, 25 December 2024)