ML19339B962

From kanterella
Jump to navigation Jump to search
Comments on Licensee Re Deletion of Drop Forged Lugs Requirement in Certificate of Compliance 5086.Submittal Fails to Address Type of Closure Ring Proposed or Capability to Meet Code Criteria for Model UNC-2600
ML19339B962
Person / Time
Site: 07105086
Issue date: 10/22/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Kirk W
UNITED NUCLEAR CORP., UNITED NUCLEAR CORP. (SUBS. OF UNC, INC.)
References
NUDOCS 8011100502
Download: ML19339B962 (1)


Text

_

$3 are f

'o UNITED STATES g

NUCLEAR REGULATORY COMMISSION e

n h

E WASHINGTON, D. C. 20555 O%

/

007 22 1980 FCTC: RHO 71-5086 UNC Naval Products ATTN: Mr. W. F. Kirk 67 Sandy Desert Road Uncasville, CT 06382 Gentlemen:

This is in reference to your September 25, 1980 letter concerning " drop forged lugs" which is required on the closure ring of the Model No. UNC-2600 packaging.

Your September 25 submittal does not adequately identify the type (or details of construction) of closure ring which you propose to use on the Model No.

UNC-2600 packaging. Also, the submittal does not show that the package, with the revised closure ring, would meet the requirements of 10 CFR Part 71 under top corner drop conditions.

Without information of this type, we cannot delete the requirement for " drop forged lugs" that is currently in Certificate of Compliance No. 5086.

Sincerely, Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS 80.11100 Sn