Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19350A340 + (09:38:07, 24 December 2024)
- ML19350A339 + (09:38:08, 24 December 2024)
- ML19350A336 + (09:38:12, 24 December 2024)
- ML19350A337 + (09:38:12, 24 December 2024)
- ML19350A333 + (09:38:13, 24 December 2024)
- ML19350A331 + (09:38:14, 24 December 2024)
- ML19350A332 + (09:38:14, 24 December 2024)
- ML19350A330 + (09:38:15, 24 December 2024)
- 05000369/LER-1981-007-03, /03L-0:on 810203,RHR Sys Train a Was Declared Inoperable.Caused by Draining Essential Header to Repair Leaking Valves in Nuclear Svc Water Sys.Valves Repaired & Train a Returned to Svc + (09:38:17, 24 December 2024)
- 05000369/LER-1981-007, Forwards LER 81-007/03L-0 + (09:38:19, 24 December 2024)
- ML19350A326 + (09:38:20, 24 December 2024)
- 05000281/LER-1981-014-03, /03L-0:on 810212,RM-CC-106 Alarm Setpoint Found Outside Tech Spec.Caused by Personnel Error.Setpoints Reset + (09:38:21, 24 December 2024)
- 05000366/LER-1981-010-03, /03L-0:on 810222,reactor Core Isolation Cooling Auto Flow Controller Did Not Control Turbine Properly While in Auto Position During Quickstart Test.Caused by Loose Ribbon Connector on Flow Control M-4 Station + (09:38:23, 24 December 2024)
- 05000366/LER-1981-010, Forwards LER 81-010/03L-0 + (09:38:25, 24 December 2024)
- 05000321/LER-1981-011-03, /03L-0:on 810214,liquid Radwaste Sample Tank, WSTB1,discharged Prior to Analysis,Contrary to Ets.Caused by Technician Error in Collecting Unit 2 Radwaste Sample in Prelabeled Unit 1 WSTB-1 Bottle + (09:38:28, 24 December 2024)
- 05000321/LER-1981-011, Forwards LER 81-011/03L-0 + (09:38:30, 24 December 2024)
- ML19350A317 + (09:38:31, 24 December 2024)
- 05000366/LER-1981-009-03, /03L-0:on 810212,reactor Coolant Not Analyzed Once Per 24-h as Required by Tech Spec.Caused by Reactor Vessel Hydro During Time Period When Next Conductivity Measurement Was to Be Taken + (09:38:32, 24 December 2024)
- 05000366/LER-1981-009, Forwards LER 81-009/03L-0 + (09:38:38, 24 December 2024)
- 05000369/LER-1981-008-03, /03L-0:on 810203,control Area Ventilation Sys Train a Declared Inoperable.Caused by Draining Essential Header to Repair Leaking Valves in Nuclear Svc Water Sys. Valves Repaired & Train a Returned to Svc + (09:38:39, 24 December 2024)
- 05000369/LER-1981-008, Forwards LER 81-008/03L-0 + (09:38:41, 24 December 2024)
- ML19350A309 + (09:38:43, 24 December 2024)
- ML19350A308 + (09:38:44, 24 December 2024)
- ML19350A306 + (09:38:45, 24 December 2024)
- ML19350A305 + (09:38:46, 24 December 2024)
- ML19350A303 + (09:38:47, 24 December 2024)
- ML19350A302 + (09:38:48, 24 December 2024)
- ML19350A301 + (09:38:49, 24 December 2024)
- ML19350A298 + (09:38:50, 24 December 2024)
- ML19350A297 + (09:38:51, 24 December 2024)
- A01558, Ack Receipt of Completed Evaluations of SEP Topics V-10.B, V-11.A,V.11.B & IX-3 Re Safe Shutdown Sys.Due to Current Refueling Outage Manpower Requirements,Comments on Evaluations Will Be Delayed from 810224 to 810401 + (09:38:52, 24 December 2024)
- ML19350A294 + (09:38:57, 24 December 2024)
- ML19350A293 + (09:38:58, 24 December 2024)
- ML19350A292 + (09:38:59, 24 December 2024)
- ML19350A291 + (09:39:00, 24 December 2024)
- ML19350A290 + (09:39:01, 24 December 2024)
- ML19350A288 + (09:39:02, 24 December 2024)
- ML19350A289 + (09:39:02, 24 December 2024)
- ML19350A287 + (09:39:03, 24 December 2024)
- ML19350A286 + (09:39:04, 24 December 2024)
- 05000387/LER-2018-005-01, Condition Prohibited by Technical Specifications Due to Drift of Reactor Pressure Switches + (09:39:06, 24 December 2024)
- ML19350A283 + (09:39:07, 24 December 2024)
- ML19350A280 + (09:39:12, 24 December 2024)
- ML19350A279 + (09:39:12, 24 December 2024)
- JAFP-81-0212, Forwards Monthly Operating Rept for Feb 1981 + (09:39:13, 24 December 2024)
- ML19350A275 + (09:39:20, 24 December 2024)
- ML19350A273 + (09:39:21, 24 December 2024)
- ML19350A272 + (09:39:21, 24 December 2024)
- ML19350A271 + (09:39:29, 24 December 2024)
- ML19350A270 + (09:39:30, 24 December 2024)
- ML19350A268 + (09:39:31, 24 December 2024)