- 05000348/LER-1981-047-01, /01T-0:on 810721,levels in Fire Protection Tanks a & B Fell to Approx 230,700 Gallons.Caused by Test Regulator Not Placed in Secured Position.Clapper Valve Opened & Deluge Sys Actuated Due to Decrease in Pressure + (12:27:12, 21 December 2024)
- ML20010A982 + (12:27:13, 21 December 2024)
- 05000366/LER-1981-071-03, /03L-0:on 810718,while Performing HNP-2-3111,MSIV D Failed to Close within Required Time Frame.Caused by Low Fluid Level in Hydraulic Operator.Operator Recharged & Filled W/Hydraulic Fluid + (12:27:15, 21 December 2024)
- 05000366/LER-1981-071, Forwards LER 81-071/03L-0 + (12:27:19, 21 December 2024)
- 05000348/LER-1981-047, Forwards LER 81-047/01T-0 + (12:27:21, 21 December 2024)
- 05000369/LER-1981-115-03, /03L-0:on 810709,while Investigating Leak Rate & Emergency Personnel Airlock Alarms,Upper Inner Personnel Airlock Door Discovered Open.Cause Unknown.Door Closed & Sealed + (12:27:23, 21 December 2024)
- 05000369/LER-1981-115, Forwards LER 81-115/03L-0 + (12:27:24, 21 December 2024)
- 05000338/LER-1981-058-03, /03L-0:on 810709,19 & 20,containment Bldg Average Air Temp Exceeded Tech Spec.Caused by High Outdoor Temp Combined W/Existing High Containment Heat Load.Temp Decreased as Day Progressed & Outdoor Temp Cooled Off + (12:27:26, 21 December 2024)
- 05000348/LER-1981-048, Forwards LER 81-048/03L-0 + (12:27:29, 21 December 2024)
- 05000321/LER-1981-074-03, /03L-0:on 810720,main Stack Offgas Flow Recorder Found Inoperative.Caused by Component Failure Due to Several Transistor Failures in Each Flow Measuring Unit.Components Replaced & Units Recalibr + (12:27:30, 21 December 2024)
- 05000338/LER-1981-058, Forwards LER 81-058/03L-0 + (12:27:32, 21 December 2024)
- 05000321/LER-1981-074, Forwards LER 81-074/03L-0 + (12:27:35, 21 December 2024)
- 05000338/LER-1981-052-03, /03L-0:on 810709,fire Dampers Found Inoperable. Caused by Fusible Links Being Located Behind Damper & Not in Ventilation Air Flow Path.Mod Initiated to Position Links within Air Stream + (12:27:39, 21 December 2024)
- 05000260/LER-1981-041-03, /03L-0:on 810709,unit Crossconnect Capability Between Units 2 & 3 Reduced to One RHR Pump When RHR Pump 3C Became Inoperable.Caused by Pump Motor Failure on Ground Overcurrent During Testing + (12:27:41, 21 December 2024)
- ML20010A960 + (12:27:42, 21 December 2024)
- 05000338/LER-1981-052, Forwards LER 81-052/03L-0 + (12:27:43, 21 December 2024)
- ML20010A957 + (12:27:44, 21 December 2024)
- 05000260/LER-1981-041, Forwards LER 81-041/03L-0 + (12:27:46, 21 December 2024)
- ML20010A954 + (12:27:47, 21 December 2024)
- ML20010A952 + (12:27:49, 21 December 2024)
- 05000348/LER-1981-049-03, /03L-0:on 810714,A Train Containment Cooler 1B Was Declared Inoperable When Motor Operated Valve Failed to Open.Caused by Motor Operated Valve Motor Winding Failure. Motor Was Replaced & Containment Cooler Returned to Svc + (12:27:50, 21 December 2024)
- ML20010A948 + (12:27:54, 21 December 2024)
- 05000324/LER-1981-068-03, /03L-0:on 810715,reactor Coolant Conductivity Found Greater than Allowable Limits.Caused by Flange Leak in RWCU Sys Effluent Strainer Blowdown Line Which Necessitated Isolating Sys.Leak Repaired.Coolant Conductivity Reduced + (12:27:55, 21 December 2024)
- ML20010A945 + (12:27:57, 21 December 2024)
- ML20010A946 + (12:27:57, 21 December 2024)
- 05000324/LER-1981-068, Forwards LER 81-068/03L-0 + (12:27:59, 21 December 2024)
- 05000348/LER-1981-049, Forwards LER 81-049/03L-0 + (12:28:00, 21 December 2024)
- L-81-332, Interim Deficiency Rept Re Failure to Follow Radiographic Procedure,Initially Reported on 810312.Twenty-five Weld Joints Still Require Repair.Final Rept Will Be Submitted by 811030 + (12:28:01, 21 December 2024)
- 05000321/LER-1981-081-01, /01T-0:on 810729,w/steady State Operation at 99% Power,Bechtel Determined That RHRSW Piping Intake Structure Was Inadequately Supported.Caused by Inadequate Scsi Design. Addl Supports Have Been Designed & Installed + (12:28:07, 21 December 2024)
- 05000321/LER-1981-081, Forwards LER 81-081/01T-0 + (12:28:09, 21 December 2024)
- ML20010A935 + (12:28:11, 21 December 2024)
- ML20010A933 + (12:28:12, 21 December 2024)
- ML20010A932 + (12:28:13, 21 December 2024)
- 05000369/LER-1981-109-03, /03L-0:on 810705,air temp-Delta T Meteorological Monitoring Strip Chart Recorder Found Not Functioning Properly.Caused by Inkwell Shaft Binding W/Inkwell Bushing Causing Pointer to Chatter & Remain at One Point + (12:28:14, 21 December 2024)
- 05000369/LER-1981-109, Forwards LER 81-109/03L-0 + (12:28:16, 21 December 2024)
- 05000369/LER-1981-108-03, /03L-0:on 810705,vacuum Pump Seized Causing Loss of Flow Alarm on EMF-33 Monitor.Caused by Condensation Being Aspirated Into Vacuum Pump Due to Improper Drainage.Damaged Pump Repaired + (12:28:17, 21 December 2024)
- 05000369/LER-1981-108, Forwards LER 81-108/03L-0.Detailed Event Analysis Encl + (12:28:19, 21 December 2024)
- A01768, Submits Addl Info Re SEP Topic V-5,RCPB Leakage Detection. Assignment of Individual Sensitivity Criterion to Devices Such as Temp Detectors & Radiation Monitors Is Impractical & Can Not Be Quantified + (12:28:21, 21 December 2024)
- ML20010A920 + (12:28:23, 21 December 2024)
- ML20010A919 + (12:28:23, 21 December 2024)
- ML20010A918 + (12:28:24, 21 December 2024)
- ML20010A917 + (12:28:25, 21 December 2024)
- ML20010A913 + (12:28:26, 21 December 2024)
- ML20010A914 + (12:28:26, 21 December 2024)
- ML20010A912 + (12:28:27, 21 December 2024)
- ML20010A911 + (12:28:28, 21 December 2024)
- 05000369/LER-1981-112-03, /03L-0:on 810706,during Initial Testing of Composite Sampler for Containment Ventilation Unit Condensate Drain Tank Line,Flow Totalizer Indicated Greater than Actual Values.Caused by Leakage in Pneumatic Fitting + (12:28:29, 21 December 2024)
- 05000369/LER-1981-116-03, /03L-0:on 810709,safety Injection Sys Train B Was Declared Inoperable Due to Centrifugal Charging Pump Discharge Line That Would Not Cycle.Caused by Mixture of Oil & Water in Gear Case of Valve + (12:28:31, 21 December 2024)
- 05000369/LER-1981-112, Forwards LER 81-112/03L-0.Detailed Event Analysis Encl + (12:28:33, 21 December 2024)
- 05000369/LER-1981-116, Forwards LER 81-116/03L-0 + (12:28:34, 21 December 2024)
- 05000369/LER-1981-117-03, /03L-0:on 810710,firedoor Found Open & No Firewatch Was Posted.Caused by Personnel Working in Area Not Letting Operations Know That Door Was Open.Door Closed & Personnel Instructed + (12:28:36, 21 December 2024)