Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- AECM-81-318, Final Deficiency Rept PRD-81/08 Re Installation of Standby Svc Water Pump,Initially Reported 810212.Item Reportable Under 10CFR50.55e But Not Under Part 21.Metal Will Be Machined from Outer Edge of Suction Bell on Four Pumps + (11:19:52, 21 December 2024)
- ML20010F160 + (11:19:54, 21 December 2024)
- 05000272/LER-1981-075-03, /03L-0:on 810809,containment Fan Coil Unit 13 Declared Inoperable Due to No Svc Water Flow Indication. Caused by Equipment Failure.Flow Transmiter FA-3543Z-1 Sensing Line Blown Clear & Transmitter Recalibr + (11:19:55, 21 December 2024)
- 05000364/LER-1981-032-03, /03L-0:on 810731,containment Atmosphere Radioactivity Monitoring Sys Was Declared Inoperable Due to Filter Paper Not Advancing.Caused by Filter Paper Spool Plates Slipping.Plates Tightened + (11:19:57, 21 December 2024)
- IR 05000329/1981008 + (11:19:59, 21 December 2024)
- ML20010F154 + (11:20:00, 21 December 2024)
- ML20010F151 + (11:20:02, 21 December 2024)
- ML20010F153 + (11:20:02, 21 December 2024)
- 05000272/LER-1981-075, Forwards LER 81-075/03L-0.Detailed Event Analysis Encl + (11:20:03, 21 December 2024)
- ML20010F148 + (11:20:04, 21 December 2024)
- ML20010F147 + (11:20:05, 21 December 2024)
- ML20010F144 + (11:20:06, 21 December 2024)
- ML20010F146 + (11:20:06, 21 December 2024)
- ML20010F143 + (11:20:07, 21 December 2024)
- ML20010F139 + (11:20:08, 21 December 2024)
- ML20010F142 + (11:20:08, 21 December 2024)
- PNO-V-81-047A, on 810903,tests Performed on Safety Injection Valves in Discharge of Main Feedwater/Safety Injection Pumps.Caused by Followup to Feedwater Transient Finding That Valves May Have Failed.Investigation Underway + (11:20:10, 21 December 2024)
- PNO-I-81-101A, on 810902,regional Inspectors Conducted re-enactment of Incident Where Exposed Individual Manipulated Collimator Containing Source W/Hand.Further Evaluation of Whole Body & Left Hand Doses to Be Conducted + (11:20:12, 21 December 2024)
- 05000324/LER-1981-088-03, /03L-0:on 810811,primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1263,Model F3M3,was Found Out of Calibr & Could Not Be Recalibr.Caused by Moisture Accumulation in Electromagnetic Unit.Unit Replaced + (11:20:14, 21 December 2024)
- IR 05000416/1981024 + (11:20:15, 21 December 2024)
- ML20010F132 + (11:20:20, 21 December 2024)
- 05000324/LER-1981-089-03, /03L-0:on 810817,primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1263-2,Model F3M3 Found W/Drywell Oxygen Concentration High.Probably Caused by Instrument Drift.Analyzer Recalibr.Analyzers to Be Replaced + (11:20:21, 21 December 2024)
- 05000324/LER-1981-088, Forwards LER 81-088/03L-0 + (11:20:23, 21 December 2024)
- PNO-V-81-046, on 810821,during Unloading of Low Level Radwaste Shipment,Metal Bin Appeared to Be Leaking Liquid. Contamination Check Indicated Radioactive Matls.State of Wa Cancelled Burial Permit & Banned Licensee Effective 810831 + (11:20:26, 21 December 2024)
- ML20010F127 + (11:20:27, 21 December 2024)
- 05000324/LER-1981-089, Forwards LER 81-089/03L-0 + (11:20:31, 21 December 2024)
- ML20010F124 + (11:20:32, 21 December 2024)
- 05000324/LER-1981-077-03, /03L-0:on 810814,rod Overtravel Annunciator Received During Verification of rod-drive Coupling for Rod 18-47.Cause Unknown.Rod Reinserted & Deactivated.Drive Will Be Removed & Inspected During Next Outage + (11:20:33, 21 December 2024)
- AECM-81-320, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/81-24.Corrective Actions:Vendor Documentation Clerk Reinstructed as to Distribution Requirements.No Proprietary Info + (11:20:34, 21 December 2024)
- 05000280/LER-1981-051-03, /03L-0:on 810804,both Charging Pump Svc Water Pumps 2-SW-P-10A & B Lost Suction & Were Secured W/Unit at 100% Power.Caused by Increased Use of Svc Water by Chillers Causing Loss of Suction Pressure + (11:20:37, 21 December 2024)
- 05000324/LER-1981-077, Forwards LER 81-077/03L-0 + (11:20:39, 21 December 2024)
- ML20010F117 + (11:20:41, 21 December 2024)
- 05000324/LER-1981-085-03, /03L-0:on 810808,rod 26-11 Did Not Have RTGB Position Indication at Position 47.Probably Caused by Defective Rod Position Indication Probe Switch.Problem Will Be Corrected During Future Outage + (11:20:42, 21 December 2024)
- 05000260/LER-1981-043-01, /01T-0:on 810815,4,160-volt Shutdown Board U-2 Was Made Critical from Cold Condition W/Start Bus Undervoltage Relays Out of Svc for Start Bus 1A.Caused by Personnel Error.Relays Were Reconnected + (11:20:44, 21 December 2024)
- 05000280/LER-1981-050-03, /03L-0:on 810804,during Routine Walkdown,Oil Discovered Being Slung from Outboard Bearing of Charging Pump A.Caused by Tube Leak in Pump Lube Oil Cooler Which Admitted Water to Lube Oil,Causing Seal Failure + (11:20:46, 21 December 2024)
- IR 05000016/1981001 + (11:20:50, 21 December 2024)
- 05000260/LER-1981-043, Forwards LER 81-043/01T-0 + (11:20:51, 21 December 2024)
- 05000324/LER-1981-085, Forwards LER 81-085/03L-0 + (11:20:53, 21 December 2024)
- 05000280/LER-1981-037-03, /03L-0:on 810806,charging Pump Svc Water Pumps 1-SW-P-10A & B Found to Have Zero Discharge Pressure Due to Loss of Suction to Pumps.Caused by Increased Use of Svc Water by Chillers During Summer Months.Strainers Cleaned + (11:20:55, 21 December 2024)
- ML20010F106 + (11:20:56, 21 December 2024)
- ML20010F105 + (11:20:57, 21 December 2024)
- AECM-81-302, Interim Deficiency Rept 1 Re Loss of Solid Metallic Grounding of Flexible Conduit,Initially Reported on 801210. Field Disposition Instructions Issued.Work Will Be Completed Prior to Fuel Load.Next Rept by 811020 + (11:20:59, 21 December 2024)
- 05000280/LER-1981-025, Forwards Updated LER 81-025/01X-1 & LERs 81-037/03L-0, 81-050/03L-0 & 81-051/03L-0 + (11:21:01, 21 December 2024)
- ML20010F099 + (11:21:03, 21 December 2024)
- ML20010F097 + (11:21:04, 21 December 2024)
- AECM-81-301, Final Deficiency Rept Re Unauthorized Mod of Heating, Ventilation & Air Conditioning Fire Dampers,Initially Reported on 801216.Deficiency Not Reportable Because Condition Would Not Affect Safety of Plant Operations + (11:21:07, 21 December 2024)
- ML20010F095 + (11:21:10, 21 December 2024)
- ML20010F093 + (11:21:11, 21 December 2024)
- ML20010F092 + (11:21:12, 21 December 2024)
- ML20010F089 + (11:21:13, 21 December 2024)
- TXX-3369, Responds to Fire Protection Open Items Referenced in NRC 810626 Memo + (11:21:14, 21 December 2024)