Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20024A616 + (05:43:28, 21 December 2024)
- ML20024A672 + (05:42:40, 21 December 2024)
- ML20024A665 + (05:42:44, 21 December 2024)
- ML20024A642 + (05:43:07, 21 December 2024)
- IR 05000295/1983007 + (05:42:54, 21 December 2024)
- ML20024A638 + (05:43:11, 21 December 2024)
- IR 05000254/1982026 + (05:42:51, 21 December 2024)
- 05000373/LER-1983-050-03, /03L-0:on 830518,administrative/clerical Errors Found in Table 3.7.9-2.Caused by Personnel Inability to Transpose Design Info Into Tech Spec Table.Discrepancies Corrected + (05:42:58, 21 December 2024)
- TAC:51717 + (05:43:47, 21 December 2024)
- ML20024A647 + (05:43:06, 21 December 2024)
- ML20024A661 + (05:42:50, 21 December 2024)
- ML20024A664 + (05:42:49, 21 December 2024)
- ML20024A674 + (05:42:37, 21 December 2024)
- ML20024A675 + (05:42:37, 21 December 2024)
- ML20024A677 + (05:42:36, 21 December 2024)
- ML20024A604 + (05:43:47, 21 December 2024)
- ML20024A607 + (05:43:45, 21 December 2024)
- ML20024A644 + (05:43:07, 21 December 2024)
- ML20024A645 + (05:43:06, 21 December 2024)
- ML20024A650 + (05:43:05, 21 December 2024)
- ML20024A651 + (05:43:03, 21 December 2024)
- ML20024A662 + (05:42:50, 21 December 2024)
- ML20024A666 + (05:42:43, 21 December 2024)
- ML20024A670 + (05:42:42, 21 December 2024)
- ML20024A671 + (05:42:41, 21 December 2024)
- ML20024A598 + (05:43:53, 21 December 2024)
- ML20024A586 + (05:44:06, 21 December 2024)
- ML20024A579 + (05:44:14, 21 December 2024)
- ML20024A546 + (05:44:43, 21 December 2024)
- ML20024A537 + (05:44:53, 21 December 2024)
- ML20024A525 + (05:45:17, 21 December 2024)
- ML20024A523 + (05:45:20, 21 December 2024)
- ML20024A592 + (05:43:58, 21 December 2024)
- ML20024A547 + (05:44:42, 21 December 2024)
- ML20024A539 + (05:44:51, 21 December 2024)
- 1CAN068308, Documents Commitment to Administratively Impose Temporary Restrictions on Plant Operating LOCA Limits as Result of NUREG-0630,per 830608 Telcon.Review of Flecset Data Requested + (05:45:14, 21 December 2024)
- GO2-83-393, Responds to NRC Re Violations Noted in IE Insp Rept 50-397/83-05.Corrective Actions:Missing Documentation Located & Reviewed.Microfilm Indexing Sys Sufficient + (05:44:54, 21 December 2024)
- GO2-83-458, Submits Amended Response to NRC Re Violations Noted in IE Insp Rept 50-397/83-05.Corrective Actions:Qa Will Issue Nonconformance Rept Re Missing Welder Qualifications,For Engineering Review + (05:44:46, 21 December 2024)
- 05000029/LER-1983-015-03, /03L-0:on 830506,during Mode 1 operation,Y177,115- Kv Line Opened for Routine Maint,Contrary to Tech Specs 3.8.1.1.a.Caused by Scheduled Maint Insp of 115-kV Transformers.No Corrective Action Necessary + (05:44:52, 21 December 2024)
- 05000296/LER-1983-029-03, /03L-0:on 830504,during Insp of 3EA 480-volt Reactor Motor Operated Valve Board Motor Generator Set, Generator Side Flywheel Bearing Found Damaged.Caused by Mispositioning of Row Balls.Bearing Replaced + (05:44:45, 21 December 2024)
- 05000346/LER-1983-023-03, /03L-0:on 830510,120-volt Ac Essential Bus Y4 Lost,Resulting in Deenergizing Reactor Protection & Safety Features Actuation Sys Channel 4.Caused by Blown Fuse in Inverter YV4.Power Restored to Bus + (05:44:59, 21 December 2024)
- 05000247/LER-1983-018-03, /03L-0:on 830422,plant Shutdown Commenced When Binding of Valve 1870 Could Not Be Corrected within Tech Spec Time Period.Cause Not Stated.Binding Alleviated by Lubricating Valve Stem & Universal Joints + (05:45:11, 21 December 2024)
- 05000247/LER-1983-013-03, /03L-0:on 830420,during Surveillance Testing of Containment Isolation Valves,Valve 1702 Did Not Fully Close. Cause Not Stated.Shaft & Inside of Actuator Cleaned.Air Motor Diaphragm Replaced as Preventive Measure + (05:45:19, 21 December 2024)
- 05000247/LER-1983-012-03, /03L-0:on 830419,reactor Cavity Continuous Sump Level Monitor LI-3302 Indicated Above 20-ft,but Independent Cavity Level Alarm Did Not Annunciate.Reactor Cavity Found Dry.Caused by Instrument Drift + (05:44:57, 21 December 2024)
- 05000249/LER-1983-019-03, /03L-0:on 830521,MSIV 203-1B Found W/Closure Time of 2.7 Exceeding Tech Spec Limit of 3 to 5 S.Caused by Misadjustment to Timing Mechanism on MSIV-203-1B.MSIV Adjusted within Tech Spec Limits + (05:45:13, 21 December 2024)
- 05000318/LER-1983-021-03, /03L-0:on 830504,containment Sump Alarms Declared Inoperable.Caused by Defective Alarm Card.Alarm Card Replaced.Annunciator Alarm Will Be Checked Daily + (05:44:50, 21 December 2024)
- IR 05000397/1983005 + (05:45:07, 21 December 2024)
- 05000309/LER-1983-017-03, /03L-0:on 830509,830517 & 18,cooling Water Outlet Stop Valve PCC-M-43 to RHR HX Failed to Open from Main Control Board.Caused by Misadjusted Valve Motor Operator Torque Settings + (05:44:37, 21 December 2024)
- ML20024A555 + (05:44:31, 21 December 2024)
- ML20024A582 + (05:44:08, 21 December 2024)
- ML20024A570 + (05:44:20, 21 December 2024)