Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20024G753 + (03:44:53, 21 December 2024)
- ML20024G752 + (03:44:54, 21 December 2024)
- ML20024G751 + (03:44:54, 21 December 2024)
- NLS9100210, Annual Radiological Environ Rept 1990 + (03:44:55, 21 December 2024)
- ML20024G749 + (03:44:57, 21 December 2024)
- ML20024G748 + (03:44:59, 21 December 2024)
- ML20024G746 + (03:45:00, 21 December 2024)
- 05000361/LER-1991-006-01, :on 910325,toxic Gas Isolation Sys Train a Actuated on High Ammonia Gas Level While Troubleshooting 910324 Failure of Channel.Caused by Location of Jumper Used to Bypass Circuitry.Jumper Will Be Relocated + (03:45:05, 21 December 2024)
- 05000456/LER-1991-005-02, :on 910326,main Control Room Ventilation Sys Shifted to Emergency Mode of Operation Due to Momentary Fluctuation in Voltage Available to Monitor.Lightning Protection Sys Being Modified + (03:45:09, 21 December 2024)
- 05000366/LER-1991-008-01, :on 910327,main Steam Isolation Valve Local Leak Rate Test Failed Due to Normal Equipment Wear Resulting in Degradation of Valve Seating Surfaces.Valves Repaired & Retested + (03:45:11, 21 December 2024)
- 05000278/LER-1991-004-02, :on 910324,reactor Operator Failed to Initial Surveillance Test 5.3, Inoperable Valve Position Daily Log. Caused by Personnel Error Due to Failure to Follow Procedure.Operator Counselled + (03:45:13, 21 December 2024)
- 05000213/LER-1991-004, :on 910301,four Containment Air Recirculation (CAR) Fans Declared Inoperable Due to Use of Inadequate Test Method for Measuring CAR Fan Air Flow.Fans Flow Vanes Adjusted & Test Reperformed Satisfactorily + (03:45:15, 21 December 2024)
- 05000413/LER-1991-006-01, :on 910323,nuclear Svc Water Valves Left W/O Emergency Power Supply.Caused by Inappropriate Action Due to Misreading of Operator Aid Computer (Oac) Graphics.Oac Graphics Training Will Be Provided + (03:45:17, 21 December 2024)
- ML20024G736 + (03:45:18, 21 December 2024)
- DD-91-01, Informs That Time Provided by NRC for Commission to Review DD-91-01 Has Expired.Commission Has Declined Review.Decision Became Final Agency Action on 910211.Served on 910304.W/ Certificate of Svc + (03:45:19, 21 December 2024)
- ML20024G733 + (03:45:21, 21 December 2024)
- ML20024G732 + (03:45:23, 21 December 2024)
- ML20024G730 + (03:45:24, 21 December 2024)
- ML20024G728 + (03:45:27, 21 December 2024)
- ML20024G727 + (03:45:27, 21 December 2024)
- ML20024G725 + (03:45:28, 21 December 2024)
- ML20024G724 + (03:45:30, 21 December 2024)
- ML20024G723 + (03:45:31, 21 December 2024)
- 05000445/LER-1991-012, :on 910326,potential Gas Binding of Centrifugal Charging Pumps Due to Voids in Boric Acid Gravity Feed Line Identified.Caused by Hydrogen Coming Out of Solution in Lower Pressure CCP Suction Header + (03:45:32, 21 December 2024)
- ML20024G720 + (03:45:33, 21 December 2024)
- 05000364/LER-1991-001-01, :on 910401,reactor Trip Occurred When Rod Dropped in Core.Caused by Defective Circuit Card in Rod Control Sys.Suspect Circuit Cards Replaced & Sent to Westinghouse for Evaluation + (03:45:35, 21 December 2024)
- 05000458/LER-1991-004, :on 910321,RCIC Turbine Main Steam Supply Line Outboard Containment Isolation Valve Isolated.Caused by Negative Trip Setpoint of Trip Unit Being Reached.Caution Added to RCIC Sys Operating Procedures + (03:45:36, 21 December 2024)
- 05000322/LER-1991-001, :on 910324,RB Normal Ventilation Sys (Rbnvs) Outboard Exhaust Valve Closed for No Apparent Reason.Cause Inconclusive.Sys Restored to Normal Lineup & Rbnvs Outboard Valve Will Be Stroked on Routine Basis + (03:45:38, 21 December 2024)
- ML20024G716 + (03:45:40, 21 December 2024)
- ML20024G715 + (03:45:40, 21 December 2024)
- ML20024G714 + (03:45:41, 21 December 2024)
- ML20024G712 + (03:45:42, 21 December 2024)
- ML20024G711 + (03:45:47, 21 December 2024)
- ML20024G710 + (03:45:50, 21 December 2024)
- ML20024G708 + (03:45:51, 21 December 2024)
- ML20024G707 + (03:45:52, 21 December 2024)
- ML20024G705 + (03:45:54, 21 December 2024)
- ML20024G706 + (03:45:54, 21 December 2024)
- ML20024G703 + (03:45:55, 21 December 2024)
- ML20024G704 + (03:45:55, 21 December 2024)
- 05000213/LER-1991-011, :on 910325,channel Check of Subcooling Margin Monitor Determined Inadequate.Caused by Failure to Adequately Incorporate Tech Spec Surveillance Requirements. Surveillance Procedures Revised + (03:45:57, 21 December 2024)
- ML20024G699 + (03:46:06, 21 December 2024)
- 05000353/LER-1991-003-03, :on 910324,inadvertent Actuation of Reactor Protection Sys Occurred.Caused by Personnel Error.Procedural Guidance Developed,Shift Training Bulletin Issued & Operator Requalification Training Module Revised + (03:46:07, 21 December 2024)
- 05000366/LER-1991-007-01, :on 910326,unknown Inadequacy in Jumper Connection Results in Scram During Surveillance in Cold Shutdown.Cause Unknown.Functional Test Completed & Surveillance Procedure Revised + (03:46:09, 21 December 2024)
- ML20024G695 + (03:46:11, 21 December 2024)
- ML20024G694 + (03:46:11, 21 December 2024)
- ML20024G692 + (03:46:12, 21 December 2024)
- ML20024G691 + (03:46:14, 21 December 2024)
- ML20024G690 + (03:46:15, 21 December 2024)
- ML20024G688 + (03:46:16, 21 December 2024)
- ML20024G686 + (03:46:17, 21 December 2024)