- ML19290D813 + (14:31:15, 2 January 2025)
- BVY 19-036, Pre-Notice of Disbursement from Decommissioning Trust + (14:31:16, 2 January 2025)
- ML19290D778 + (14:31:18, 2 January 2025)
- ML19290D766 + (14:31:19, 2 January 2025)
- ML19290D761 + (14:31:20, 2 January 2025)
- ML19290D762 + (14:31:20, 2 January 2025)
- ML19290D759 + (14:31:21, 2 January 2025)
- PNO-I-80-008, on 800116,crack in Core Spray Sparger Piping Discovered During Routine Inservice Insp Conducted Per Refueling Outage.Crack Located Inside Reactor Shroud. Investigation Underway.Extension of Outage Anticipated + (14:31:23, 2 January 2025)
- PNO-I-80-022, on 800205,contractor Employee Fell Into Spent Fuel Pool.Caused by Blow to Head.No Overexposure Occured & No Water Was Ingested.Counts Indicate 0.078 Uci Fixed Skin Contamination.Media Coverage Evident + (14:31:25, 2 January 2025)
- ML19290D692 + (14:31:26, 2 January 2025)
- PNO-I-80-004, evaluation Disclosed Automatic Depressurization Sys Nitrogen Supply Not Seismically Qualified Outside & Possibly Unqualified Drywell.Nss Vendor Issuing Ltr & 10CFR21 Considerations Being Evaluated + (14:31:28, 2 January 2025)
- ML19290D678 + (14:31:29, 2 January 2025)
- ML19290D675 + (14:31:31, 2 January 2025)
- ML19290D673 + (14:31:32, 2 January 2025)
- PNO-IV-80-006, on 800205,discovered Malicious Damage to Two Stator Windings of Unit 2 Diesel Generator A.Caused by Unknown Persons.Damage Can Be Repaired Onsite + (14:31:34, 2 January 2025)
- ML19290D662 + (14:31:35, 2 January 2025)
- ML19290D661 + (14:31:36, 2 January 2025)
- ML19290D659 + (14:31:37, 2 January 2025)
- ML19290D658 + (14:31:38, 2 January 2025)
- ML19290D656 + (14:31:38, 2 January 2025)
- ML19290D655 + (14:31:39, 2 January 2025)
- ML19290D654 + (14:31:41, 2 January 2025)
- ML19290D650 + (14:31:43, 2 January 2025)
- 05000366/LER-1980-009-03, /03L-0:on 800130,while Performing Procedure HNP-2-33-3,HPCI Min Flow Valve 2E41-F012 Failed to Close. Caused by Sticking Switch Contacts on Flow Switch 2E41-N006. Switch Contacts Cleaned & Procedure HNP-2-3303 Performed + (14:31:44, 2 January 2025)
- ML19290D648 + (14:31:45, 2 January 2025)
- ML19290D647 + (14:31:46, 2 January 2025)
- 05000366/LER-1980-009, Forwards LER 80-009/03L-0 + (14:31:47, 2 January 2025)
- ML19290D644 + (14:31:48, 2 January 2025)
- 05000254/LER-1980-002-03, /03L-0:on 800111,while Performing in-place Charcoal Absorber Leak Rate Test on Standby Gas Treatment sys,1.93% Leakage Found.Caused by Damaged Gasket on 4x4 Inch Access Plate.Gasket Replaced + (14:31:49, 2 January 2025)
- ML19290D641 + (14:31:51, 2 January 2025)
- ML19290D640 + (14:31:51, 2 January 2025)
- ML19290D639 + (14:31:53, 2 January 2025)
- 05000254/LER-1980-002, Forwards LER 80-002/03L-0 + (14:31:54, 2 January 2025)
- 05000266/LER-1980-001-01, /01T-0:on 800202,during Routine Calibr of Pressure Transmitters for Motor Driven Auxiliary Feed Pumps, Transmitter Isolation Block Valves Discovered Closed.Caused by Inadvertent Closing of Isolation Valves.Snubbers Added + (14:31:56, 2 January 2025)
- ML19290D635 + (14:31:57, 2 January 2025)
- 05000295/LER-1980-005-03, /03L-0:on 800110,miscellaneous Vent Gas Rod Monitor ORT-PR18A Failed Low During Cold Shutdown.Caused by Dirty &/Or worn-down Contacts on Mother Board of Module. Contacts Cleaned & Connections Resoldered + (14:31:59, 2 January 2025)
- ML19290D633 + (14:32:00, 2 January 2025)
- ML19290D632 + (14:32:01, 2 January 2025)
- 05000295/LER-1980-005, Forwards LER 80-005/03L-0 + (14:32:02, 2 January 2025)
- ML19290D626 + (14:32:04, 2 January 2025)
- ML19290D627 + (14:32:04, 2 January 2025)
- ML19290D625 + (14:32:06, 2 January 2025)
- 05000304/LER-1980-001-03, /03L-0:on 800113,trip of Auxiliary Transformer 242 Caused Power Supplies for Radiation Monitor Blowers to de-energize.Caused by Loose Heat Shield Due to High Winds. Work Requests Written to Repair Heat Shields + (14:32:07, 2 January 2025)
- 05000266/LER-1980-001, Forwards LER 80-001/01T-0 + (14:32:09, 2 January 2025)
- ML19290D621 + (14:32:10, 2 January 2025)
- 05000321/LER-1980-010-03, /03L-0:on 800118,during Normal Operation While Performing Standby Liquid Control Pump Operability Test & Relief Valve Test,Pump a Discharge Relief Valve 1C41-F029A Operated at 1,225 Psig.Caused by Setpoint Drift.Valve Reset + (14:32:12, 2 January 2025)
- 05000304/LER-1980-001, Forwards LER 80-001/03L-0 + (14:32:13, 2 January 2025)
- ML19290D616 + (14:32:15, 2 January 2025)
- 05000321/LER-1980-010, Forwards LER 80-010/03L-0 + (14:32:16, 2 January 2025)
- ML19290D611 + (14:32:17, 2 January 2025)
- 05000219/LER-1980-002-03, /03L-0:on 800116,during Fuel Bundle Clip Insp,Fuel Bundle UD-3-023 Was Misoriented & Was Not Properly Seated in Core Cell Location.Caused by Personnel Error & Inadequate Procedural Controls.Procedure 205 Revised + (14:32:22, 2 January 2025)