- 05000369/LER-1982-018, Forwards LER 82-018/03L-0 + (15:10:48, 18 December 2024)
- ML20050B073 + (15:10:49, 18 December 2024)
- ML20050B072 + (15:10:50, 18 December 2024)
- 05000280/LER-1982-031-03, /03L-0:on 820222,RHR Sample Sys Containing Isolation Trip valve,TV-SS-103A,opened W/O Operator Action & Could Not Be Closed from Control Room.Cause Not Yet Identified.Redundant Trip Valve Closed + (15:10:52, 18 December 2024)
- ML20050B070 + (15:10:53, 18 December 2024)
- 05000324/LER-1982-040-03, /03L-0:on 820217,routine Surveillance Revealed Drywell Floor Drain Flow integrator,2-G16-FQ-K601,was Continuously Counting W/No Pump Running.Cause Not Found. Mod to Vortex Type Flowmeter Will Be Installed + (15:10:57, 18 December 2024)
- ML20050B067 + (15:10:59, 18 December 2024)
- ML20050B063 + (15:11:06, 18 December 2024)
- ML20050B064 + (15:11:06, 18 December 2024)
- 05000324/LER-1982-040, Forwards LER 82-040/03L-0 + (15:11:11, 18 December 2024)
- ML20050B059 + (15:11:12, 18 December 2024)
- 05000269/LER-1982-002-01, /01T-0:on 820222,control Operator Moved Group 8 Control Rods Into Tech Spec Restricted Area to Clear Core Axial Imbalance Alarm.Caused by Operator Error.Rod Position Corrected & Computer Alarms Modified to Include Group 8 + (15:11:13, 18 December 2024)
- 05000295/LER-1982-011-01, /01T-0:on 820317,RHR Suction Pressure Transmitter 1PT-403 Failed High & Suction Valve 1MOV-RH8702 Started to Close.Caused by Piece of Sheet Metal Accidentally Dropped on Inverter 111 Output Breaker.Breaker Reclosed + (15:11:16, 18 December 2024)
- ML20050B054 + (15:11:18, 18 December 2024)
- 05000263/LER-1981-001-03, While Performing Surveillance Test Mo 2035,HPCI Outboard Steam Supply Isolation Valve Failed to Close.Caused by Opened Limitorque SMB-O,240-volt Dc & Torque Switches.Switches Replaced + (15:11:19, 18 December 2024)
- 05000295/LER-1982-011, Forwards LER 82-011/01T-0 + (15:11:21, 18 December 2024)
- ML20050B049 + (15:11:22, 18 December 2024)
- ML20050B047 + (15:11:23, 18 December 2024)
- ML20050B046 + (15:11:24, 18 December 2024)
- A02190, Comments on 811223 Draft Evaluation for SEP Topic VIII-4, Electrical Penetrations of Reactor Containment. Containment Integrity Will Be Maintained During Fault or Overcurrent Event W/Primary Protective Device Failure + (15:11:25, 18 December 2024)
- ML20050B040 + (15:11:27, 18 December 2024)
- 05000263/LER-1981-001, Forwards Updated LER 81-001/03X-1 + (15:11:29, 18 December 2024)
- ML20050B035 + (15:11:33, 18 December 2024)
- 05000269/LER-1982-002, Forwards LER 82-002/01T-0.Detailed Event Analysis Encl + (15:11:35, 18 December 2024)
- ML20050B031 + (15:11:40, 18 December 2024)
- 05000325/LER-1982-036-01, /01T-0:on 820308,valve Operator Motor from 1-E11-F002A Removed from Valve W/O Following Appropriate Procedures,Rendering RHR Svc Water Subsystem Inoperable. Caused by Communication Breakdown Among Maint Personnel + (15:11:41, 18 December 2024)
- ML20050B028 + (15:11:42, 18 December 2024)
- ML20050B026 + (15:11:43, 18 December 2024)
- 05000325/LER-1982-036, Forwards LER 82-036/01T-0 + (15:11:44, 18 December 2024)
- ML20050B023 + (15:11:45, 18 December 2024)
- ML20050B022 + (15:11:46, 18 December 2024)
- ML20050B020 + (15:11:48, 18 December 2024)
- 05000287/LER-1982-002-03, /03L-0:on 820210,reactor Protection Sys Channel B Hot Leg Temp Readings Were Lower than Those of Channels A,C & D.Caused by Failure of Liner Bridge in Input Circuitry for Channel B Indication.Bridge Replaced + (15:11:51, 18 December 2024)
- W3P82-0652, Discusses Resolution of Hydrological & Geotechnical Engineering Branch Concerns Re Availability of Installed Sump Pumps in Dry Cooling Towers During Intense Precipitation Events.Portable Pump Will Be Provided + (15:11:52, 18 December 2024)
- ML20050B015 + (15:11:55, 18 December 2024)
- IR 05000334/1981019 + (15:11:56, 18 December 2024)
- 05000315/LER-1982-013-03, /03L-0:on 820302,control Switch for Containment Pressure Equalization Fan in Stop & Backdraft Damper for Opposite Fan Was Open.Cause Could Not Be Determined.Startup Procedures Revised + (15:12:01, 18 December 2024)
- 05000287/LER-1982-002, Forwards LER 82-002/03L-0.Detailed Event Analysis Encl + (15:12:02, 18 December 2024)
- ML20050B009 + (15:12:03, 18 December 2024)
- 05000338/LER-1982-010-03, /03L-0:on 820223,post-reactor Trip Specific Activity Samples of RCS Indicated Dose Equivalent I-131 Level Greater than Tech Spec Limit.Caused by Fuel Element Defect.Sampling Frequency Accelerated + (15:12:05, 18 December 2024)
- ML20050B006 + (15:12:06, 18 December 2024)
- ML20050B005 + (15:12:10, 18 December 2024)
- 05000409/LER-1982-003-03, /03L-0:on 820313,during Type B Leakage Test on Personnel Airlock,Manometer Read Incorrectly.Caused by Inadequate Tightening of Strongbacks on Inner Door.Need for Tight Installation Emphasized & Procedure Revised + (15:12:18, 18 December 2024)
- 05000315/LER-1982-012-03, /03L-0:on 820303,turbine Driven Auxiliary Feedwater Pump Trip/Throttle Valve Tripped Shut When Manually Started.No Problems Found.Surveillance Test Completed.Pump Returned to Svc.No Further Action Planned + (15:12:20, 18 December 2024)
- ML20050B000 + (15:12:22, 18 December 2024)
- ML20050A994 + (15:12:27, 18 December 2024)
- 05000260/LER-1982-011-03, /03L-0:on 820215,during Operation,While Performing Chamber Water check,2-LI-64-66 Indicated Improper Torus & Level & Declared Inoperable.Caused by Instrument Drift & Possible Air in Ref Leg.Transmitter Calibr + (15:12:28, 18 December 2024)
- 05000335/LER-1982-009-03, /03L-0:on 820317,while Operating at 98% Power, Weekly Surveillance of Core Barrel Movement Required by Tech Spec 3.4.11 Was Not Performed.Surveillance Was Inadvertently Overlooked.Personnel Instructed to Perform Surveillance + (15:12:30, 18 December 2024)
- ML20050A991 + (15:12:31, 18 December 2024)
- 05000260/LER-1982-011, Forwards LER 82-011/03L-0 + (15:12:33, 18 December 2024)
- 05000327/LER-1982-028-03, /03L-0:on 820214 & 15,in Mode 3,cold Leg Accumulator 4 Declared Inoperable Due to Low Boron Concentration.Caused by Leak Through in Flow Control Leak Test & Fill Line Valves.Five Valves Investigated & Repaired + (15:12:34, 18 December 2024)