Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20066D264 + (23:34:57, 16 December 2024)
- ML20066D265 + (23:34:57, 16 December 2024)
- ML20066D260 + (23:34:58, 16 December 2024)
- ML20066D253 + (23:34:59, 16 December 2024)
- ML20066D248 + (23:34:59, 16 December 2024)
- ML20066D238 + (23:35:00, 16 December 2024)
- ML20066D234 + (23:35:01, 16 December 2024)
- 05000305/LER-1982-032-03, /03L-0:on 821004,discovered That Outer Door of Personnel Airlock Exceeded Leak Rate Specs.Cause Not Stated. Shim Installed Under Outer Seal.Door Retested Satisfactorily + (23:35:03, 16 December 2024)
- ML20066D226 + (23:35:04, 16 December 2024)
- ML20066D229 + (23:35:04, 16 December 2024)
- ML20066D224 + (23:35:05, 16 December 2024)
- 05000352/LER-1990-034, :on 901209,reactor Mode Switch Placed in Shutdown,Placing Unit in Hot Shutdown Due to Inoperability of Loop B of RHR Svc Water Sys.On 901206,outlet Valve Declared Inoperable.Threaded Area Welded + (23:35:07, 16 December 2024)
- ML20066D220 + (23:35:08, 16 December 2024)
- 05000305/LER-1982-032, Forwards LER 82-032/03L-0 + (23:35:09, 16 December 2024)
- 05000416/LER-1990-028, :on 901210,ESF,RPS & ECCS Hpsc Actuated, Resulting in Reactor Scram from Full Power.Caused by Failed Solder Joint in Instrument Air Sys & Leaking Root Valve. Joint Reinspected & Procedures Revised + (23:35:11, 16 December 2024)
- ML20066D214 + (23:35:12, 16 December 2024)
- 05000456/LER-1990-022-02, :on 901207,discovered That on 901121,fuel Handling Bldg Crane Interlocks Inadequate to Prevent Movement Over East Corner of Spent Fuel Pool.Caused by Procedural Deficiency.Procedures Revised + (23:35:14, 16 December 2024)
- ML20066D204 + (23:35:15, 16 December 2024)
- 05000440/LER-1990-039, :on 901211,discovered That Both Loops of Containment Spray Mode of RHR Sys Inoperable.Caused by Inadequate Instructions.Instructions Revised to Include Isolation Valve for Position Verification + (23:35:17, 16 December 2024)
- ELV-02398, Provides Comments on SALP Rept, + (23:35:18, 16 December 2024)
- 05000440/LER-1990-038, :on 901211,control Room Noble Gas Radiation Monitor Inoperable for More than 7 Days W/O Taking Compensatory Actions.Caused by Personnel Error.Valve Lineup Instruction Changed & Monitor Will Be Included in Training + (23:35:21, 16 December 2024)
- AECM-82-532, Advises That Operability Testing of Safety Relief Valves for RHR HX & Fuel Oil Sys Completed Per SER Suppl 2.All Lift Pressures within 3% of Valve Rating + (23:35:22, 16 December 2024)
- PY-CEI-NRR-1292, Forwards LERs 90-038-00 & 90-039-00 + (23:35:22, 16 December 2024)
- 3F0191-09, Requests Schedule Change for 910118 Enforcement Conference Due to Need to Obtain Certain Info Not Available Prior to Issues Raised in NRC + (23:35:23, 16 December 2024)
- BECO-91-002, Advises That Util Selected Alternative Flow Path for Obtaining post-accident Sampling Sys Samples That Satisfies 30-day Sampling Requirement of Item II.B.3 of NUREG-0737. Path Will Be Verified During Refueling Outage 8 + (23:35:23, 16 December 2024)
- ML20066D171 + (23:35:24, 16 December 2024)
- ELV-02433, Documents Results of NRC Dec 1990 Review Re Implementation of License Amends Issued 900710.Mod & Associated Tech Spec Change Consistent W/Intent of Reg Guide 1.9 + (23:35:25, 16 December 2024)
- ML20066D164 + (23:35:25, 16 December 2024)
- 2CAN118202, Forwards C-E Effects of Vessel Head Voiding During Transients & Accidents in C-E NSSS, Per NUREG-0737,Item II.K.2.17 & Provides Docket Ref for CEN-203-P,Revision 1, Transmitted by ,In Response to Item II.K.3.30 + (23:35:26, 16 December 2024)
- ML20066D158 + (23:35:27, 16 December 2024)
- ML20066D159 + (23:35:27, 16 December 2024)
- ML20066D156 + (23:35:28, 16 December 2024)
- ML20066D155 + (23:35:30, 16 December 2024)
- ML20066D151 + (23:35:32, 16 December 2024)
- ML20066D147 + (23:35:33, 16 December 2024)
- ML20066D150 + (23:35:33, 16 December 2024)
- 2CAN108205, Forwards Monthly Operating Rept for Sept 1982 + (23:35:34, 16 December 2024)
- PLA-1338, Forwards Monthly Operating Rept for Sept 1982 + (23:35:34, 16 December 2024)
- ML20066D135 + (23:35:35, 16 December 2024)
- ML20066D133 + (23:35:36, 16 December 2024)
- NRC-91-0001, Forwards Investigation Rept Into False Negative Results of Blind Performance Specimen Received from Metpath Lab + (23:35:39, 16 December 2024)
- ML20066D123 + (23:35:40, 16 December 2024)
- ML20066D110 + (23:35:40, 16 December 2024)
- ML20066D108 + (23:35:43, 16 December 2024)
- ML20066D106 + (23:35:44, 16 December 2024)
- ML20066D103 + (23:35:44, 16 December 2024)
- 05000237/LER-1982-040-03, Valve 2-1601-33A Exhibited Binding During Movement.Caused by Excess Packing Grease in Chevron Packing Seal.Packing Grease Bled Out.Valve Tested & Determined Operable + (23:35:47, 16 December 2024)
- 05000237/LER-1982-040, Forwards Updated LER 82-040/03X-1 + (23:35:48, 16 December 2024)
- ML20066D096 + (23:35:48, 16 December 2024)
- ML20066D083 + (23:35:49, 16 December 2024)
- ML20066D084 + (23:35:49, 16 December 2024)
- 05000249/LER-1982-039-03, /03L-0:on 821015,during DOS 1500-3,component Cooling Svc Water (Ccsw) Pump Test,Submarine Door to Ccsw Pump Vault Found Open.Caused by Personnel Error.Door Closed. Personnel Reminded to Keep Door Closed + (23:35:51, 16 December 2024)