- ML20070K825 + (14:29:54, 16 December 2024)
- 05000339/LER-1982-082, Forwards LER 82-082/03L-0 + (14:29:55, 16 December 2024)
- ML20070K811 + (14:29:56, 16 December 2024)
- ML20070K806 + (14:29:57, 16 December 2024)
- ML20070K801 + (14:30:01, 16 December 2024)
- ML20070K797 + (14:30:02, 16 December 2024)
- ML20070K790 + (14:30:04, 16 December 2024)
- ML20070K788 + (14:30:05, 16 December 2024)
- NRC-94-4234, Forwards Westinghouse Responses to Requests for Addl Info on AP600 from Ltrs of 940428,29,0502,05,11,16,18,23,24,26,0601 & 08.Listing of NRC Requests for Addl Info Responded to in Ltr Contained in Attachment a + (14:30:06, 16 December 2024)
- ML20070K782 + (14:30:08, 16 December 2024)
- ML20070K774 + (14:30:11, 16 December 2024)
- 05000261/LER-1982-018, Forwards LER 82-018/01L-0 + (14:30:12, 16 December 2024)
- ML20070K760 + (14:30:13, 16 December 2024)
- ML20070K759 + (14:30:14, 16 December 2024)
- 05000338/LER-1982-091-03, /03L-0:on 821207,during Mode 4,pressure in Nitrogen Reservoir B for Pressurizer PORV (PCV-1455C) Dropped Below Min.Caused by Excessive Nitrogen Leakage Through Nitrogen Reservoir B Relief Valve.Valve Repaired + (14:30:19, 16 December 2024)
- ML20070K735 + (14:30:20, 16 December 2024)
- ML20070K726 + (14:30:21, 16 December 2024)
- ML20070K731 + (14:30:21, 16 December 2024)
- 05000325/LER-1982-149-01, /01T-0:on 821209,limiting Conditions for Operation Initiated on Primary Containment Isolation Sys Instrument 1-B21-PDTM-N006-D-1 Due to Downscale Indications.Caused by Operator Error.Signal Reinserted + (14:30:23, 16 December 2024)
- 05000338/LER-1982-091, Forwards LER 82-091/03L-0 + (14:30:24, 16 December 2024)
- ML20070K716 + (14:30:24, 16 December 2024)
- 05000325/LER-1982-144-03, /03L-0:on 821127,suppression Chamber Water Temp Recorder 1-CAC-TR-778,located on Remote Shutdown Panel, Periodically Failed to Record.Caused by Recorder Print Mechanism Relay K3 Out of Adjustment.Relay Adjusted + (14:30:26, 16 December 2024)
- 05000325/LER-1982-149, Forwards LER 82-149/01T-0 + (14:30:27, 16 December 2024)
- 05000325/LER-1982-144, Forwards LER 82-144/03L-0 + (14:30:28, 16 December 2024)
- ML20070K699 + (14:30:28, 16 December 2024)
- 05000339/LER-1982-080-03, /03L-0:on 821206,during Mode 1,individual RPI for Rod H-02 in Control Bank D Deviated from Group Demand Position by Greater than 12 Steps W/No Rod Motion.Caused by Instrument Drift.Rpi Channel Recalibr & Returned to Svc + (14:30:30, 16 December 2024)
- L-82-547, Interim Deficiency Rept Re Lack of Documentation on Class I & II Bolts & Nuts.Initially Reported on 821013.Final Rept Will Be Submitted by 830126 + (14:30:31, 16 December 2024)
- ML20070K682 + (14:30:31, 16 December 2024)
- 05000339/LER-1982-080, Forwards LER 82-080/03L-0 + (14:30:32, 16 December 2024)
- ML20070K666 + (14:30:36, 16 December 2024)
- ML20070K673 + (14:30:36, 16 December 2024)
- ML20070K662 + (14:30:37, 16 December 2024)
- 05000338/LER-1982-087-03, /03L-0:on 821205,during Mode 1,individual RPI for Rod H-02 in Control Bank D Deviated from Group Demand Position by Greater than 12 Steps W/No Rod Motion.Caused by Instrument Drift.Rpi Channel Recalibr & Returned to Svc + (14:30:39, 16 December 2024)
- ML20070K654 + (14:30:40, 16 December 2024)
- ML20070K655 + (14:30:40, 16 December 2024)
- 05000338/LER-1982-087, Forwards LER 82-087/03L-0 + (14:30:41, 16 December 2024)
- ML20070K649 + (14:30:42, 16 December 2024)
- ML20070K645 + (14:30:43, 16 December 2024)
- ML20070K643 + (14:30:44, 16 December 2024)
- 05000339/LER-1982-078-03, /03L-0:on 821205,during Mode 1,containment Average Air Temp Exceeded 105 F.Caused by Temp Increase of Chilled Water to Containment Air Recirculation Cooling Coils Due to Temporary Inoperability of Mechanical Refrigeration Un + (14:30:46, 16 December 2024)
- ML20070K639 + (14:30:47, 16 December 2024)
- 05000338/LER-1982-084-03, /03L-0:on 821205,at 20% Power,Channels FI-1475 & FI-1485 for Steam Generators a & B Steam Flow Showed Below Actual Flow.Caused by Transmitter for FI-1475 & Multiplier/ Divider/Square Root for FI-1485 Being Out of Calibr + (14:30:49, 16 December 2024)
- 05000339/LER-1982-078, Forwards LER 82-078/03L-0 + (14:30:51, 16 December 2024)
- ML20070K627 + (14:30:51, 16 December 2024)
- ML20070K624 + (14:30:53, 16 December 2024)
- ML20070K621 + (14:30:54, 16 December 2024)
- 05000364/LER-1982-050-03, /03L-0:on 821124,source Range Channel N32 Declared Inoperable Due to Erratic Readings.Caused by Faulty Detector on N31 & Faulty High Voltage Power Supply Cable Connector on N32.Detector & Cable Connector Replaced + (14:30:55, 16 December 2024)
- 05000338/LER-1982-084, Forwards LER 82-084/03L-0 + (14:30:56, 16 December 2024)
- ML20070K606 + (14:30:59, 16 December 2024)
- BSEP-82-2906, RO 1-82-154:on 821214,while Detensioning Reactor Vessel Head,Operational Mode 5 Entered W/O Meeting Tech Spec 3.0.4 Requirements.Investigation Underway & Mode 5 Requirements Under Review + (14:31:00, 16 December 2024)
- 05000364/LER-1982-048-03, /03L-0:on 821127,source Range Channel N-32 Declared Inoperable Due to Loss of Detector Voltage.Caused by Faulty High Voltage Connector.Connector Replaced + (14:31:02, 16 December 2024)
- ML20070K595 + (14:31:03, 16 December 2024)