Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20070L545 + (14:27:00, 16 December 2024)
- ML20070L541 + (14:27:01, 16 December 2024)
- ML20070L539 + (14:27:02, 16 December 2024)
- ML20070L534 + (14:27:04, 16 December 2024)
- 05000311/LER-1982-141-03, /03L-0:on 821121 & 1204,RCS Subcooling Monitor Declared Inoperable.Caused by Parity Error in R-250 Computer Due to Insufficient Ventilation.Computer Reprogrammed & Temporary Fan Installed + (14:27:06, 16 December 2024)
- 05000361/LER-1982-156-03, /03L-0:on 821130,review of Operational Surveillance Records Revealed That RCS Water Inventory Balance Due 821128 Had Been Missed Contrary to Tech Spec. Caused by Unstable Plant Conditions + (14:27:11, 16 December 2024)
- 05000361/LER-1982-145-03, /03L-0:on 821115,review of Operational Surveillance Records Revealed That RCS Water Inventory Balance Had Not Been Performed in 157 H Per Tech Spec.Caused by Unstable Plant condition.Sign-off Sys Initiated + (14:27:13, 16 December 2024)
- W3P82-4063, Advises of Need to Reanalyze Limiting Large Break LOCA Re Containment Purge Data & Safety Injection Tank Flow Testing. C-E ECCS Evaluation Flow Blockage Model Used to Perform Reanalysis.Draft Analysis Results Expected by 830304 + (14:27:14, 16 December 2024)
- ML20070L510 + (14:27:14, 16 December 2024)
- ML20070L508 + (14:27:15, 16 December 2024)
- ML20070L506 + (14:27:15, 16 December 2024)
- ML20070L498 + (14:27:16, 16 December 2024)
- ML20070L499 + (14:27:16, 16 December 2024)
- ML20070L492 + (14:27:17, 16 December 2024)
- ML20070L483 + (14:27:18, 16 December 2024)
- ML20070L490 + (14:27:18, 16 December 2024)
- ML20070L476 + (14:27:19, 16 December 2024)
- ML20070L480 + (14:27:19, 16 December 2024)
- ML20070L473 + (14:27:20, 16 December 2024)
- ML20070L469 + (14:27:20, 16 December 2024)
- ML20070L463 + (14:27:21, 16 December 2024)
- ML20070L448 + (14:27:22, 16 December 2024)
- ML20070L451 + (14:27:22, 16 December 2024)
- ML20070L445 + (14:27:23, 16 December 2024)
- ML20070L440 + (14:27:24, 16 December 2024)
- A09341, Responds to NRC 910211 Notice of Violation Noted in Insp Rept 336/90-22 & Forwards Payment of Civil Penalty in Amount of $50,000.Corrective Actions:Fuel Movement Halted When Atmospheric Dump Valve Discovered Open + (14:27:25, 16 December 2024)
- ML20070L415 + (14:27:26, 16 December 2024)
- ML20070L413 + (14:27:27, 16 December 2024)
- ML20070L409 + (14:27:28, 16 December 2024)
- ML20070L402 + (14:27:29, 16 December 2024)
- 0CAN128213, Forwards Final Response to NUREG-0612, Control of Heavy Loads at Nuclear Power Plants, Addressing Overhead Handling Sys in Vicinity of Fuel Storage Pools & Containment & Safe Load Paths + (14:27:30, 16 December 2024)
- 05000366/LER-1982-115-03, /03L-0:on 821122,core Spray RHR Permissive Pressure Switch B Found Inoperable During Calibr Procedure. Caused by High Setpoint Micro Switch Failure to Actuate. Micro Switch Replaced,Calibr & Returned to Svc on 821217 + (14:27:32, 16 December 2024)
- 05000366/LER-1982-115, Forwards LER 82-115/03L-0 + (14:27:33, 16 December 2024)
- 05000275/LER-1982-012-01, /01T-0:on 821206,radiation Survey of Spent Fuel Pool Not Performed in Accordance W/Tech Spec 3.3.3.1.Caused by Personnel Error.Technician Counseled + (14:27:38, 16 December 2024)
- 05000341/LER-1991-002, :on 910215,emergency Diesel Generators 11 & 13 Inoperable Due to Problems on Woodard Governor Motor Operated Potentiometers.Edg Have Been Tested,Examined & Maint Procedures Will Be in Effect + (14:27:40, 16 December 2024)
- ML20070L341 + (14:27:41, 16 December 2024)
- ML20070L339 + (14:27:42, 16 December 2024)
- ML20070L333 + (14:27:43, 16 December 2024)
- ML20070L332 + (14:27:44, 16 December 2024)
- 05000275/LER-1982-012, Forwards LER 82-012/01T-0 + (14:27:45, 16 December 2024)
- 05000277/LER-1991-005-01, :on 910212,primary Containment Isolation Sys Actuated Due to Blown Fuse During Removal of Blocking Permit Caused by Ground Created While Performing Mod Installation Work.Shift Permit Enforced + (14:27:46, 16 December 2024)
- ML20070L310 + (14:27:47, 16 December 2024)
- 05000354/LER-1991-004, :on 910203,ESF Actuation & Primary Containment Isolation Sys Actuation Occurred While Manipulating Vessel Level Instrument.Caused by Inherent Sensitivity of Reactor Vessel.Incident Will Be Reviewed W/Technicians + (14:27:49, 16 December 2024)
- ML20070L303 + (14:27:50, 16 December 2024)
- 1CAN128206, Advises That Revisions to BAW-10154P, B&W Small Break LOCA ECCS Evaluation Model & BAW-10092P, Craft 2, Are Endorsed & Applicable to Facility + (14:27:51, 16 December 2024)
- ML20070L301 + (14:27:51, 16 December 2024)
- NLS9100117, Application for Amend to License DPR-46,revising Tech Specs Table 4.2.B Re Functional Test Frequency for RHR Sys Initiation & RHR Sys Pump & Valve Control Logic + (14:27:52, 16 December 2024)
- 05000361/LER-1982-001-01, /01T-0:on 821128,emergency Chiller E-335 Declared Inoperable,Rendering Creacus Train B Inoperable.Caused by Failure of Resistance Temp Detector in Motor Winding High Temp Trip Circuit.Spare Resistance Temp Detector Installed + (14:27:54, 16 December 2024)
- 1CAN128209, Requests That 820929 Proposed Tech Spec Change Re Steam Line Break Instrumentation & Control Sys Setpoint Be Withdrawn, Since Concerns Expressed in NRC 821206 Request for Addl Info Cannot Be Adequately Addressed W/O Mods to Sys + (14:27:55, 16 December 2024)
- 05000296/LER-1982-056-03, /03L-0:on 821128,particulate Channel on 3-90-256 Drywell CAM Went Downscale Due to Moisture in Sample Chamber.Caused by Accumulation of Condensation in Sample Chamber of NMC Model AM-331F CAM.O-rings Replaced + (14:27:56, 16 December 2024)
- 05000361/LER-1982-142-01, /01T-0:on 821128,emergency Chiller E-335 Declared Inoperable,Rendering Creacus Train B Inoperable.Caused by Failure of Resistance Temp Detector in Motor Winding High Temp Trip Circuit.Spare Resistance Temp Detector Installed + (14:27:59, 16 December 2024)