- ML20071D589 + (11:50:21, 15 December 2024)
- 05000346/LER-1983-007, Forwards LER 83-007/03L-0 + (11:50:22, 15 December 2024)
- ML20071D583 + (11:50:22, 15 December 2024)
- 05000327/LER-1983-020, Forwards LER 83-020/03L-0 + (11:50:23, 15 December 2024)
- ML20071D577 + (11:50:24, 15 December 2024)
- ML20071D573 + (11:50:24, 15 December 2024)
- 05000316/LER-1983-025-03, /03L-0:on 830203 & 05,fire Door 374 to Startup Blowdown Flash Tank Area Would Not Close Against Air Flow Through Door Opening.Door Closer Mechanism & Closer Arm & Screws Replaced.Door Closer Adjusted + (11:50:26, 15 December 2024)
- ML20071D570 + (11:50:27, 15 December 2024)
- ML20071D569 + (11:50:28, 15 December 2024)
- 05000361/LER-1983-011-03, /03L-0:on 830127,control Element Assembly Calculator 1 Revealed Loss of Position Indication for Control Element Assembly 28.Caused by Faulty Isolation Amplifier Card.Card Replaced + (11:50:29, 15 December 2024)
- ML20071D563 + (11:50:30, 15 December 2024)
- ML20071D561 + (11:50:30, 15 December 2024)
- 05000361/LER-1983-011, Forwards LER 83-011/03L-0 + (11:50:31, 15 December 2024)
- 05000316/LER-1983-025, Forwards LER 83-025/03L-0 + (11:50:45, 15 December 2024)
- ML20071D546 + (11:50:45, 15 December 2024)
- ML20071D543 + (11:50:46, 15 December 2024)
- ML20071D537 + (11:50:54, 15 December 2024)
- RBG-14-481, Interim Deficiency Rept DR-72 Re Improper Installation, Testing & Insp of Concrete Drilled in expansion-type Anchors.Initially Reported on 820830.Addl Info from S&W Expected.Final Rept Will Be Provided by 830425 + (11:50:55, 15 December 2024)
- ML20071D532 + (11:50:56, 15 December 2024)
- ML20071D533 + (11:50:56, 15 December 2024)
- ML20071D531 + (11:50:57, 15 December 2024)
- TXX-3637, Describes How Station Has Satisfied Human Factors Guidance Re Sys Function Task analysis.Plant-specific Emergency Response Guidelines Procedure Prepared Per NUREG-0899 to Determine Discrepancies W/Control Board + (11:50:57, 15 December 2024)
- ML20071D525 + (11:50:58, 15 December 2024)
- ML20071D527 + (11:50:58, 15 December 2024)
- ML20071D523 + (11:50:59, 15 December 2024)
- 05000334/LER-1983-005-99, /99X-0:on 830212,main Steam Trip Valve TV-MS-101B Shut on Loss of Air Causing Momentary Drop in Steam Line Pressure Initiating Safety Injection/Reactor Trip.Caused by Separated Sweated Fitting.Fitting Repaired + (11:51:00, 15 December 2024)
- ML20071D519 + (11:51:01, 15 December 2024)
- ML20071D516 + (11:51:02, 15 December 2024)
- ML20071D518 + (11:51:02, 15 December 2024)
- ML20071D514 + (11:51:03, 15 December 2024)
- 05000362/LER-1983-021-03, /03L-0:on 830131,tendon 9 Required Liftoff Force in Excess of Tech Spec.Caused by Less than Anticipated Relaxation Rate When Liftoff Values Calculated.Tech Spec Change Will Correct Liftoff Force Criteria + (11:51:05, 15 December 2024)
- 05000362/LER-1983-021, Forwards LER 83-021/03L-0 + (11:51:06, 15 December 2024)
- ML20071D507 + (11:51:06, 15 December 2024)
- 05000260/LER-1983-004, Forwards LER 83-004/01T-0 + (11:51:07, 15 December 2024)
- ML20071D497 + (11:51:08, 15 December 2024)
- ML20071D491 + (11:51:08, 15 December 2024)
- ML20071D490 + (11:51:09, 15 December 2024)
- ML20071D488 + (11:51:12, 15 December 2024)
- 05000362/LER-1983-009-03, /03L-0:on 830130,containment high-range Radiation Monitor Channel RI-7820-2 Failed During Surveillance Test. Cause Not Determined.Monitor Channel Electrical Unit Replaced & Unit Returned to Manufacturer for Analysis + (11:51:13, 15 December 2024)
- ML20071D483 + (11:51:14, 15 December 2024)
- 05000305/LER-1983-004-03, /03L-0:on 830204,water Found Dripping Into Controller for Valve AFW-10 During Investigation of Battery Ground Fault Condition on Battery 1A.Caused by Wet Rags Stuffed in Newly Drilled Holes in Concrete Wall + (11:51:15, 15 December 2024)
- ML20071D480 + (11:51:16, 15 December 2024)
- 05000362/LER-1983-009, Forwards LER 83-009/03L-0 + (11:51:17, 15 December 2024)
- PMNS20200221, Notice of Meeting with Southern Nuclear Operating Company + (11:51:17, 15 December 2024)
- ML20071D473 + (11:51:18, 15 December 2024)
- 05000334/LER-1983-005, Forwards LER 83-005/99X-0 + (11:51:19, 15 December 2024)
- ML20071D469 + (11:51:19, 15 December 2024)
- PMNS20200220, Notice of Meeting with Southern Nuclear Operating Company + (11:51:20, 15 December 2024)
- 05000327/LER-1983-016-03, /03L-0:on 830205,ice Condenser Temp Monitoring Sys Recorder in Main Control Room Declared Inoperable.Print Head Assembly,Westronics Model M11-E,failed Upscale.Cause Unknown.New Recorder Installed + (11:51:21, 15 December 2024)
- PMNS20200218, Notice of Meeting with Southern Nuclear Operating Company + (11:51:22, 15 December 2024)
- ML20071D451 + (11:51:23, 15 December 2024)