- 05000255/LER-1983-020-01, /01T-0:on 830321,discovered That Current Core Safety Analysis Does Not Account for Response Times of PCS Resistance Temp Device (Rtd).Caused by Oversight of Analyst to Include RTD Response Time in Analysis + (08:59:12, 15 December 2024)
- ML20073D194 + (08:59:12, 15 December 2024)
- ML20073D190 + (08:59:13, 15 December 2024)
- ML20073D183 + (08:59:14, 15 December 2024)
- 05000369/LER-1983-012-03, /03L-0:on 830302,four Existing Auxiliary Feedwater Flow Transmitters Determined Not Environmentally Qualified for 330 F Main Steam Break Environ.Transmitter Overlooked in Review Response to NUREG-0588 + (08:59:15, 15 December 2024)
- 05000446/LER-1994-013, :on 940817,four of Twenty Valves Tested Had Lift Settings Outside the Plus or Minus 1 Percent Setpoint Tolerance.Cause Not Determined.Setpoint Changes Request Submitted + (08:59:17, 15 December 2024)
- 05000335/LER-1983-018, Forwards LER 83-018/03L-0 + (08:59:18, 15 December 2024)
- 05000255/LER-1983-020, Forwards LER 83-020/01T-0 + (08:59:19, 15 December 2024)
- ML20073D169 + (08:59:19, 15 December 2024)
- ML20073D167 + (08:59:20, 15 December 2024)
- 05000369/LER-1983-012, Forwards LER 83-012/03L-0 + (08:59:22, 15 December 2024)
- ML20073D161 + (08:59:22, 15 December 2024)
- ML20073D152 + (08:59:23, 15 December 2024)
- L-91-127, Forwards Rev 30 to Physical Security Plan.Rev Withheld (Ref 10CFR2.790(a)(3) & 73.21) + (08:59:24, 15 December 2024)
- 05000325/LER-1983-011-03, /03L-0:on 830307,PT 35.11.1 Fire Hose Station RB-42 Found Inoperable Due to Disconnected Fire Hose.Cause Unknown.Memo Stressing Importance of Maintaining Operability of Fire Hose Station Issued + (08:59:26, 15 December 2024)
- ML20073D142 + (08:59:27, 15 December 2024)
- 05000373/LER-1983-021-01, /01T-0:on 830323,during IEEE-323 Environ Qualification Testing,Circuit Breakers CB-13,11 & 9 Found to Have Thermal Overload Trip & Reset Problems in Simulated post-LOCA Environ.Caused by Incorrect Breaker Selection + (08:59:28, 15 December 2024)
- ML20073D136 + (08:59:29, 15 December 2024)
- ML20073D134 + (08:59:29, 15 December 2024)
- ML20073D128 + (08:59:30, 15 December 2024)
- ML20073D123 + (08:59:31, 15 December 2024)
- ML20073D118 + (08:59:32, 15 December 2024)
- 05000324/LER-1983-032-03, /03L-0:on 830315,during PT-1.1.12PC,main Steam Line Radiation Monitor 2-D12-LRM-K603A Actuated Above Tech Spec Limit.Caused by Alignment & Alarm Setpoints Out of calibr.K603A Calibr & PT-1.1.12PC Completed + (08:59:33, 15 December 2024)
- 05000325/LER-1983-011, Forwards LER 83-011/03L-0 + (08:59:34, 15 December 2024)
- 05000373/LER-1983-021, Forwards LER 83-021/01T-0 + (08:59:35, 15 December 2024)
- ML20073D105 + (08:59:35, 15 December 2024)
- AECM-83-0211, RO 83-017/0:on 830301,latch to Fire Door OC313 in Control Bldg Discovered Damaged Resulting in Alarmed Condition for Fire Zone.Hourly Fire Watch Established.Latch Mechanism Expected to Be Repaired by 830430 + (08:59:36, 15 December 2024)
- ML20073D098 + (08:59:36, 15 December 2024)
- ML20073D096 + (08:59:37, 15 December 2024)
- ML20073D089 + (08:59:39, 15 December 2024)
- 05000324/LER-1983-032, Forwards LER 83-032/03L-0 + (08:59:40, 15 December 2024)
- BSEP-83-1122, RO 2-83-43:on 830405,required Actions for Inoperable Fire Barriers in Augmented Gas Bldg Not Taken During Evaluation of Fire Protection Limiting Conditions.Continuous Fire Watches Established + (08:59:40, 15 December 2024)
- ML20073D075 + (08:59:41, 15 December 2024)
- 05000327/LER-1983-041-03, /03L-0:on 830311,during Surveillance Instruction 196,three of Four Level switches,1-1S-87-21,23 & 24,found Out of Tolerance.Caused by Instrument Drift & Calibr & Testing Techniques.Switches Recalibr & Returned to Svc + (08:59:42, 15 December 2024)
- 05000327/LER-1983-037-03, /03L-0:on 830314,w/unit in Mode 1,steam Flow Channel 1-FT-1-10B Failed High.Caused by Air in Sense Line.Line Backfilled & Bled + (08:59:44, 15 December 2024)
- ML20073D067 + (08:59:45, 15 December 2024)
- 05000327/LER-1983-041, Forwards LER 83-041/03L-0 + (08:59:46, 15 December 2024)
- AECM-83-0208, RO 83-013/0:on 830301 & 03,Fire Doors 1A109,0C709 & 0C710 Blocked Open to Perform Planned Maint Activities.Hourly Fire Watches Being Conducted.Completion Date for Work Is 830425 + (08:59:46, 15 December 2024)
- ML20073D051 + (08:59:47, 15 December 2024)
- ML20073D050 + (08:59:48, 15 December 2024)
- ML20073D048 + (08:59:49, 15 December 2024)
- ML20073D043 + (08:59:51, 15 December 2024)
- ML20073D044 + (08:59:51, 15 December 2024)
- 05000327/LER-1983-037, Forwards LER 83-037/03L-0 + (08:59:52, 15 December 2024)
- PY-CEI-NRR-1345, Responds to NRC Re Violations Noted in Insp Rept 50-440/91-03 on 910108-0228.Corrective Actions:Shift Supervisor Discussed Open Feeder Breaker W/Control Room Unit Supervisor,Stressing Need to Utilize Proper Refs + (08:59:52, 15 December 2024)
- ML20073D028 + (08:59:53, 15 December 2024)
- ML20073D022 + (08:59:54, 15 December 2024)
- ML20073D018 + (08:59:54, 15 December 2024)
- JAFP-91-0245, Requests Waiver of Compliance for APRM Instrument Functional Test Frequency,Contained in Tech Spec Table 4.1-1.If Waiver Not Granted,Plant Will Need to Shut Down Unnecessarily.Proposed Waiver Encl + (08:59:55, 15 December 2024)
- ML20073D004 + (08:59:56, 15 December 2024)
- ML20073D001 + (08:59:58, 15 December 2024)
- 05000366/LER-1983-012-03, /03L-0:on 830307,RCIC Isolated on Exhaust Diaphragm High Pressure During Surveillance Procedure HNP-2-3405.Caused by Component Failure.Inboard & Outboard Rupture Discs Replaced & Added to Yearly Maint Schedule + (08:59:59, 15 December 2024)