Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20073R208 + (08:22:33, 15 December 2024)
- AECM-83-0252, RO 83-023/0:on 830312,two Smoke Detectors in Standby Gas Treatment Filter Train Room,Zone 2-19 Covered During Welding Activities to Prevent Actuation.Similar Event Occurred on 830315.Detector Operability to Be Restored by 830315 + (08:22:34, 15 December 2024)
- ML20073R204 + (08:22:34, 15 December 2024)
- ML20073R197 + (08:22:35, 15 December 2024)
- ML20073R194 + (08:22:36, 15 December 2024)
- ML20073R193 + (08:22:36, 15 December 2024)
- ML20073R190 + (08:22:37, 15 December 2024)
- ML20073R186 + (08:22:37, 15 December 2024)
- AECM-83-0253, RO 83-024/0:on 830319 & 30,several Smoke Detectors in Control Room Zones 1-18 & Auxiliary Bldg Corridors,Elevation 139 Ft,Respectively,Covered to Prevent Actuation During Welding.Fire Watches Established + (08:22:38, 15 December 2024)
- ML20073R174 + (08:22:39, 15 December 2024)
- ML20073R177 + (08:22:39, 15 December 2024)
- ML20073R170 + (08:22:43, 15 December 2024)
- ML20073R168 + (08:22:43, 15 December 2024)
- 05000324/LER-1983-037, Forwards LER 83-037/03L-0 + (08:22:44, 15 December 2024)
- ML20073R163 + (08:22:44, 15 December 2024)
- BSEP-83-1236, Ro:Fire Barrier Limiting Conditions for Operation Issued on 830317 & 20 Exceeded 7-day Time Frame to Permit Completion of Mods in Control,Diesel Generator & Augmented Offgas Bldgs.Continuous Stationed Fire Watches Maintained + (08:22:48, 15 December 2024)
- ML20073R159 + (08:22:48, 15 December 2024)
- ML20073R157 + (08:22:49, 15 December 2024)
- ML20073R154 + (08:22:50, 15 December 2024)
- ML20073R156 + (08:22:50, 15 December 2024)
- ML20073R150 + (08:22:51, 15 December 2024)
- BSEP-83-1240, RO:7-day Specified Time Frame of Four Fire Barrier Limiting Conditions for Operation Exceeded,To Permit Work in Augmented Offgas & Control Bldgs for Installation of Two Plant Mods.Fire Watches Will Remain in Effect + (08:22:52, 15 December 2024)
- ML20073R146 + (08:22:52, 15 December 2024)
- GO2-83-358, Interim Deficiency Repts Re IE Circular 81-05, Sway Strut/ Snubber End Bushings & Anaconda Flexible Conduit.Initially Reported on 821202 & 830321,respectively.Quarterly Updates Will Continue to Be Provided.Next Rept Expected by 830720 + (08:22:53, 15 December 2024)
- ML20073R143 + (08:22:53, 15 December 2024)
- BSEP-83-1202, Nonroutine Radiological Environ Event Rept.Results of 830308 Gamma Analysis of Bottom Sediment Revealed High Co-60 Concentration.Samples Will Be Taken Monthly for Oct 1982 - June 1983 to Determine If Trends Can Be Predicted + (08:22:54, 15 December 2024)
- ML20073R135 + (08:22:55, 15 December 2024)
- ML20073R133 + (08:22:55, 15 December 2024)
- ML20073R127 + (08:22:56, 15 December 2024)
- ML20073R131 + (08:22:56, 15 December 2024)
- ML20073R124 + (08:22:57, 15 December 2024)
- 05000325/LER-1983-017-03, /03L-0:on 830326-28 & 0402,listed Control Rods Had No Indications for Identified Positions.Caused by Loose Prototypic Inlet Piping Connectors in Each Rod Attributed to Undervessel Work.Plant Mods Scheduled + (08:22:59, 15 December 2024)
- ML20073R110 + (08:23:00, 15 December 2024)
- ML20073R112 + (08:23:00, 15 December 2024)
- ML20073R106 + (08:23:01, 15 December 2024)
- 05000219/LER-1983-014-01, /01T-0:on 830406,design Deficiency Discovered in Heating Coil Control Circuitry for Standby Gas Treatment Sys Trains.Temporary Redundant Power Feed Provided Until Permanent Mod Installed During Current Maint Outage + (08:23:02, 15 December 2024)
- 05000219/LER-1983-014, Forwards LER 83-014/01T-0.Detailed Event Analysis Encl + (08:23:03, 15 December 2024)
- ML20073R088 + (08:23:04, 15 December 2024)
- ML20073R084 + (08:23:05, 15 December 2024)
- ML20073R081 + (08:23:05, 15 December 2024)
- ML20073R071 + (08:23:06, 15 December 2024)
- RBG-14-866, Interim Deficiency Rept DR-72 Re Improper Installation (Torquing),Testing & Insp of Concrete drilled-in expansion- Type Anchors.Evaluation in Progress.Interim or Final Rept Will Be Sent by 830610 + (08:23:06, 15 December 2024)
- PY-CEI-NRR-1360, Special Rept:On 910418,alarms Generated by Noise Spike in 60 Hz Range Due to Inoperable Loose Parts in Detection Sys Instrumentation.Possible Corrective Actions Include Replacement of Cable or Detector + (08:23:07, 15 December 2024)
- ML20073R061 + (08:23:08, 15 December 2024)
- ML20073R058 + (08:23:08, 15 December 2024)
- ML20073R056 + (08:23:09, 15 December 2024)
- 05000331/LER-1983-008-31, /03L-0:on 830326,eight Accessible Hydraulic Snubbers Visually Inspected & Deficiencies Noted. Surveillance Procedure STP 46H002 Revised to Address Mechanical Aspects in Addition to Hydraulic Mechanism + (08:23:10, 15 December 2024)
- 05000331/LER-1983-008, Forwards LER 83-008/03L-0 + (08:23:11, 15 December 2024)
- ML20073R047 + (08:23:12, 15 December 2024)
- ML20073R046 + (08:23:13, 15 December 2024)
- ML20073R045 + (08:23:14, 15 December 2024)
- 05000313/LER-1983-009-03, /03L-0:on 830405,during Hot Shutdown After Refueling Outage,Discovered That Nonqualified Diaphragm Was Used to Repair Pressure Switch PS-7503 in Standby Hydrogen Purge Sys.Qualified Pressure Switch Obtained & Installed + (08:23:15, 15 December 2024)