Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20083F674 + (10:55:21, 14 December 2024)
- 05000289/LER-1983-044-01, /01T-1:on 831114,during Walkdown,Emergency Feedwater Automatic Initiation Redundant Circuits Discovered Routed in Same Cable Bundle.Caused by Failure to Include Circuits in Upgrade Design + (10:55:22, 14 December 2024)
- 05000325/LER-1983-054-03, /03L-0:on 831119,routine Surveillance Revealed That Div I Primary Containment Atmosphere Oxygen/Hydrogen Analyzer Not Showing Expected Decrease in Oxygen Concentration.Caused by Worn Seals + (10:55:24, 14 December 2024)
- ML20083F663 + (10:55:26, 14 December 2024)
- 05000275/LER-1983-030-03, /03L-0:on 831116,discovered That Tech Spec Surveillance Requirement 4.3.3.3.1 for Channel Functional Test of Triaxial Time History Accelographs Not Performed. Caused by Personnel Error + (10:55:27, 14 December 2024)
- BSEP-83-3994, Nonroutine 30-day Radiological Environ Event Rept 2-SR-83-32 Re Gamma Analysis Results of Bottom Sediment sample.Co-60 Activity Increased by Factor of 10 Above MDA + (10:55:28, 14 December 2024)
- 05000327/LER-1983-177-03, /03L-0:on 831122,diesel Generator 2A-A Declared Inoperable Due to Failure to Trip on Demand During Relay Testing.Cause of Failure of Differential Relay 87A Unknown. Relay Replaced + (10:55:30, 14 December 2024)
- ML20083F651 + (10:55:31, 14 December 2024)
- ML20083F652 + (10:55:31, 14 December 2024)
- 05000366/LER-1983-138-03, /03L-0:on 831206,diesel Generator 2C(2R43-S001C) Could Not Be Shut Down W/Local or Control Room Stop Switch. Caused by Loose Governor Shutdown Solenoid Due to Engine Vibration.Solenoid Repositioned + (10:55:33, 14 December 2024)
- 05000334/LER-1983-036-03, /03L-0:on 831104,reactor Coolant Pump Thermal Barrier CCR Isolation Valves TV-CC-107A,B & C Not Stroked as Outlined in Inservice Insp Program.After 1980 Inservice Insp Rev,Valves Inadvertently Omitted + (10:55:35, 14 December 2024)
- ML20083F645 + (10:55:36, 14 December 2024)
- ML20083F646 + (10:55:36, 14 December 2024)
- 05000302/LER-1983-057-03, /03L-0:on 831122,during Emergency Feedwater Sys Operability Demonstration,Motor Actuator for Turbine Driven Emergency Feedwater Pump Steam Admission Valve ASV-5 Found Inoperable.Caused by Contact Failure + (10:55:38, 14 December 2024)
- 05000333/LER-1983-059-04, /04T-0:on 831129,periphyton Exceeded 10 Times Control Sample for Co-60.Caused by Bioaccumulation Factor for Element.No Radiation Dose to Man Expected + (10:55:40, 14 December 2024)
- ML20083F640 + (10:55:41, 14 December 2024)
- ML20083F637 + (10:55:44, 14 December 2024)
- 05000416/LER-1983-130-03, Shutdown Cooling Sys Isolated Twice When Suction Valve Received Isolation Signals.First Isolation Caused by Personnel Error.Second Caused by Use of Alligator Clips + (10:55:48, 14 December 2024)
- ML20083F628 + (10:55:49, 14 December 2024)
- 05000261/LER-1983-029-03, /03L-0:on 831122,w/unit Shut Down for Steam Generator Insp Outage,Level Transmitter LT-928 Found to Be Out of Calibr.Caused by Instrument Drift.Transmitter Recalibr + (10:55:50, 14 December 2024)
- ML20083F625 + (10:55:54, 14 December 2024)
- ML20083F624 + (10:55:55, 14 December 2024)
- 05000251/LER-1983-020-03, /03L-0:on 831123,during Return to Operation After Addition of full-flow Recirculation Piping,Reactor Taken Critical Before Piping Hydrotested at Pump Discharge Pressure.Caused by Previous Outmoded Hydrotest + (10:55:56, 14 December 2024)
- ML20083F621 + (10:55:57, 14 December 2024)
- ML20083F620 + (10:55:57, 14 December 2024)
- TXX-4089, Forwards Revised Pages from Chapter 17.1 of Fsar,Amend 44, Reflecting QA Program Decription Change.Rev Does Not Reduce Util Commitments Nor QA Program Effectiveness + (10:55:58, 14 December 2024)
- PLA-1968, Final Deficiency & Part 21 Repts Re Final Design of GE 7700 Series 250-volt Dc Control Ctrs.Plant Operating Procedures Revised to Include Methods of Clearing Obstructions as Provided by GE & Exam & Reforming of Draw Out Contacts + (10:55:59, 14 December 2024)
- ML20083F617 + (10:55:59, 14 December 2024)
- L-20-033, Submittal of Annual Financial Report + (10:56:00, 14 December 2024)
- ML20083F598 + (10:56:01, 14 December 2024)
- ML20083F596 + (10:56:02, 14 December 2024)
- ML20083F597 + (10:56:02, 14 December 2024)
- 05000321/LER-1983-072-03, /03L-0:on 831121,during Reactor Bldg Vent Radiation & Arm Sys Calibr Procedure HNP-1-5114,control Room Radiation Sensors 241-N0154A & B Found Out of Tolerance. Caused by Setpoint Drift.Sensors Adjusted + (10:56:06, 14 December 2024)
- ML20083F592 + (10:56:07, 14 December 2024)
- 05000327/LER-2020-001-01, 1 for Sequoyah Nuclear Plant, Unit 1, Containment Vacuum Relief Lines Found Isolated + (10:56:09, 14 December 2024)
- ML20083F589 + (10:56:10, 14 December 2024)
- 05000325/LER-1983-052-03, /03L-0:on 831122,while Performing Operability Test,Control Room Indicators CAC-LI-2601-1 & LI-4177 & Remote Shutdown Panel CAC-LI-3342 Showed Level Indication - 26 Inches.Caused by Cracked Open Drain Valve + (10:56:11, 14 December 2024)
- ML20083F586 + (10:56:12, 14 December 2024)
- 05000318/LER-1983-063-03, /03L-0:on 831102,containment Particulate & Gaseous Monitor Skid Isolation Valve Inadvertently Shut.Caused by Close Proximity to Containment Sample Valve.Locking Device Attached to Prevent Closure + (10:56:14, 14 December 2024)
- ML20083F581 + (10:56:15, 14 December 2024)
- ML20083F579 + (10:56:16, 14 December 2024)
- ML20083F578 + (10:56:17, 14 December 2024)
- ML20083F571 + (10:56:17, 14 December 2024)
- 05000313/LER-1983-023, Updated LER 83-023/03X-6:on 830916-1120,fire Protection Deficiencies Discovered.Caused by Inadequate Original Installation Specs & Acceptance Criteria.Walkdown Insp in Progress.Insp Program Being Developed + (10:56:18, 14 December 2024)
- ML20083F570 + (10:56:18, 14 December 2024)
- ML20083F556 + (10:56:19, 14 December 2024)
- ML20083F558 + (10:56:19, 14 December 2024)
- ML20083F554 + (10:56:23, 14 December 2024)
- ML20083F553 + (10:56:23, 14 December 2024)
- ML20083F551 + (10:56:24, 14 December 2024)
- ML20083F549 + (10:56:24, 14 December 2024)