o TABLE 15.4.1-2 (Continued)

Test Frequency f

24.

Integrity of Post Evaluate Each refueling cycle Accident Systems Outside Containment 25.

Containment Purge Supply Verify valves are Monthly (9) and Exhaust Isolation locked closed Valves

]

(1)

R,equired only during periods of power operation.

(2)

E determination will be started when the gross activity analysis of a filtered sample indicates > 10pc/cc and will be redetermined if the primary coolant gross radioactivity of a filtered sample increases by more than 10 pc/cc.

(3) Drop tests shall be conducted at rated reactor coolant flow. Rods shall be dropped under both cold and hot conditions, but cold drop tests need not be timed.

(4) Drop tests will be conducted in the hot condition for rods on which maintenance was performed.

(5) As accessible without disassembly of rotor.

(6) Not required during periods of refueling shutdown.

(7) At least once per week during periods of refueling shutdown.

(8) At least three times per week (with maximum time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> between samples) during periods of refueling shutdown.

(9) Not required during periods of cold or refueling shutdown.

(10) During end-of-cycle period of operation when boron concentration is less than 100 ppn, this test may be waived due to operational limitations.

(11)

Sample to be taken after a minimum of 2 EFPD and 20 days power operation since the reactor was last subcritical for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or longer.