Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000387/LER-1982-078-03, /03L-0:on 821218,during Startup Testing Program, Two Jet Pumps Did Not Indicate Flowrate.Caused by Air Trapped in Lines.Air Bled Off & Indicators Returned to Normal.Source of Air Could Not Be Determined + (10:25:33, 14 December 2024)
- 05000296/LER-1983-005-03, /03L-0:on 821222,while Performing Monthly Vibration Tests on 480-volt Reactor Motor Operator Valve Board Motor Generator Sets,High Vibration Readings Detected on 3DA Set Coupling.Caused by Excessive Seal Removal + (10:25:34, 14 December 2024)
- NRC-95-0051, Monthly Operating Rept for Apr 1995 for Fermi 2 + (10:25:35, 14 December 2024)
- 05000395/LER-1982-066-03, /03L-0:on 821226,during Mode 1 Operation,Reactor Bldg Sump Leakage Detection Sys Declared Inoperable When High Level Alarm Remained in Alarm State.Caused by Failure of Capacitance Level Detection Sys.Sys Recalibr + (10:25:37, 14 December 2024)
- 05000395/LER-1982-063-03, /03L-0:on 821220,isotopic Iodine Analysis Not Performed within 6 H After Plant Went from 5% to 21% Thermal Power within 1 H.Caused by Failure to Notify Chemistry Dept to Perform Analysis.Procedure Developed + (10:25:39, 14 December 2024)
- 05000387/LER-1982-078, Forwards LER 82-078/03L-0 + (10:25:40, 14 December 2024)
- 05000361/LER-1982-167, Forwards LER 82-167/03L-0.Detailed Event Analysis Submitted + (10:25:41, 14 December 2024)
- 05000395/LER-1982-066, Forwards LER 82-066/03L-0.Detailed Event Analysis Encl + (10:25:44, 14 December 2024)
- 05000219/LER-1982-060-03, /03L-0:on 821210,reactor Mode Switch Repositioned from Shutdown to Refuel While Intermediate Range Monitor Channels 16 & 17 Out of Svc.Caused by Personnel Error.Strict Compliance W/Tech Specs Emphasized + (10:25:48, 14 December 2024)
- ML20083M368 + (10:25:49, 14 December 2024)
- ML20083M367 + (10:25:50, 14 December 2024)
- 05000237/LER-1983-001-03, /03L-0:on 830101,cracked Weld Discovered at Feedwater Heater 2D2 Emergency Spill to Normal Drain Line Connector.Caused by Excessive Movement of Drain Line.Weld Will Be Repaired During Upcoming Refueling Outage + (10:25:51, 14 December 2024)
- 05000387/LER-1983-001, Forwards LER 83-001/01T-0 + (10:25:52, 14 December 2024)
- ML20083M358 + (10:25:56, 14 December 2024)
- 05000361/LER-1982-150-01, /01T-0:on 821229,Kerotest Valve Incorrectly Installed Restricting Flow Through Liquid Radwaste Monitor RT-7813.Caused by Improper Installation.Valve Realigned & Liquid Effluent Releases Sampled + (10:25:57, 14 December 2024)
- ML20083M356 + (10:25:58, 14 December 2024)
- 05000237/LER-1983-001, Forwards LER 83-001/03L-0 + (10:25:59, 14 December 2024)
- ML20083M352 + (10:26:02, 14 December 2024)
- ML20083M350 + (10:26:03, 14 December 2024)
- 05000219/LER-1982-060, Forwards LER 82-060/03L-0.Detailed Event Analysis Encl + (10:26:04, 14 December 2024)
- ML20083M348 + (10:26:04, 14 December 2024)
- 05000387/LER-1984-017, :on 840310,spray Pond Riser Networks A-1 & B-2 Found Frozen.Cause Not Stated.Networks Thawed by Ambient Temp & Guidelines Developed for Spray Pond Operation to Avoid Riser Freezing + (10:26:06, 14 December 2024)
- 05000296/LER-1983-005, Forwards LER 83-005/03L-0 + (10:26:12, 14 December 2024)
- ML20083M344 + (10:26:12, 14 December 2024)
- 05000265/LER-1983-001-03, /03L-0:on 830102,offgas Radiation Monitor 1 Failed.Caused by Faulty Resistor in Power Supply to Monitor. Resistor Replaced + (10:26:14, 14 December 2024)
- ML20083M337 + (10:26:15, 14 December 2024)
- 05000361/LER-1982-150, Forwards LER 82-150/01T-0.Detailed Event Analysis Submitted + (10:26:16, 14 December 2024)
- 05000395/LER-1982-063, Forwards LER 82-063/03L-0.Detailed Event Analysis Encl + (10:26:16, 14 December 2024)
- ML20083M326 + (10:26:17, 14 December 2024)
- 05000247/LER-1982-049-99, /99X-0:on 821218,during Cycle 5/6 Refueling Outage,Ability of Central Control Room to Be Totally Isolated During Accidents Questioned Because Potential Air Leak Paths Identified.All Potential Paths Sealed + (10:26:21, 14 December 2024)
- ML20083M317 + (10:26:22, 14 December 2024)
- 05000265/LER-1983-001, Forwards LER 83-001/03L-0 + (10:26:26, 14 December 2024)
- ML20083M314 + (10:26:30, 14 December 2024)
- 05000250/LER-1982-019-03, /03L-0:on 821223,while Performing Full Length Rod Control Cluster Periodic Exercise,Rod Control Cluster J3 of Shutdown Bank a Failed to Show Proper Movement.Cause Unknown.Cluster Performed Normally During Rod Exercise + (10:26:31, 14 December 2024)
- ML20083M310 + (10:26:32, 14 December 2024)
- 05000373/LER-1982-175-03, /03L-0:on 821224,div 2 Position Indicator of Containment Vacuum Breaker 1PCOO1B Would Not Indicate Closed.Cause Undetermined.Work Request Written,Insp Performed & Vacuum Breaker Repeatedly Cycled + (10:26:34, 14 December 2024)
- ML20083M304 + (10:26:38, 14 December 2024)
- ML20083M303 + (10:26:39, 14 December 2024)
- ML20083M299 + (10:26:40, 14 December 2024)
- ML20083M293 + (10:26:41, 14 December 2024)
- 05000373/LER-1982-175, Forwards LER 82-175/03L-0 + (10:26:45, 14 December 2024)
- ML20083M288 + (10:26:45, 14 December 2024)
- ML20083M287 + (10:26:46, 14 December 2024)
- ML20083M286 + (10:26:50, 14 December 2024)
- 05000395/LER-1982-062-03, /03L-0:on 821220,seismic Switch YM-1782 Found to Have out-of-tolerance Trip Point on Transverse Sensor. Caused by Setpoint Drift on Horizontal Transverse Sensor. Switch Calibr & Returned to Svc + (10:26:52, 14 December 2024)
- 05000250/LER-1982-019, Forwards LER 82-019/03L-0 + (10:26:53, 14 December 2024)
- ML20083M281 + (10:26:53, 14 December 2024)
- ML20083M278 + (10:26:54, 14 December 2024)
- ML20083M273 + (10:26:57, 14 December 2024)
- ML20083M270 + (10:26:58, 14 December 2024)
- 05000247/LER-1982-049, Forwards LER 82-049/99X-0 + (10:26:59, 14 December 2024)
- 05000395/LER-1982-062, Forwards LER 82-062/03L-0.Detailed Event Analysis Encl + (10:26:59, 14 December 2024)