Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20085N396 + (07:56:45, 14 December 2024)
- ML20085N400 + (07:56:45, 14 December 2024)
- ML20085N393 + (07:56:46, 14 December 2024)
- ML20085N384 + (07:56:46, 14 December 2024)
- ML20085N382 + (07:56:47, 14 December 2024)
- SNRC-1860, Informs of Plans to Continue Using NRC Approved Plans Entitled Snps Security Training... W/Rev Through 900918 & Snps Safeguards... W/Revs Through 880513,per 911104 Request for Exemption from 10CFR73.55 + (07:56:47, 14 December 2024)
- 05000219/LER-1991-006, :on 910924,check Revealed Degradation in Flow Dampening Snubber Performance for Seven of Eight Sensors. Caused by Inadequate Design Control.Snubbers Removed from Pipe Break Sensors + (07:56:49, 14 December 2024)
- ML20085N378 + (07:56:50, 14 December 2024)
- ML20085N375 + (07:56:50, 14 December 2024)
- NLS9100717, Suppls Proposed Change 88 to License DPR-46,revising Spec 5.2.B Re Control Rod Absorber Matl,Dtd 910423,per NRC Request + (07:56:51, 14 December 2024)
- ML20085N370 + (07:56:52, 14 December 2024)
- ML20085N368 + (07:56:52, 14 December 2024)
- ML20085N365 + (07:56:53, 14 December 2024)
- 05000440/LER-1991-022, :on 911011,while Manipulating Front Panel Switches on Drywell Atmospheric Gaseous Monitor,Radiation Monitor Indication Spiked Upscale.Caused by Unrecognized Equipment Characteristics.Info Tag Attached to Monitor + (07:56:55, 14 December 2024)
- ML20085N356 + (07:56:56, 14 December 2024)
- 05000440/LER-1991-021, :on 911011,preferred Source Breaker Would Not Close on Demand from Switch on Control Room Panel Since 910904.Caused by Equipment Malfunction.Spring Pins on Tooling Racks Will Be Shortened & Instruction Revised + (07:56:58, 14 December 2024)
- PY-CEI-NRR-1414, Forwards LERs 91-021-00 & 91-022-00 + (07:56:58, 14 December 2024)
- ML20085N351 + (07:57:00, 14 December 2024)
- 05000302/LER-1991-009, :on 911008,discovered That Relays & Fuses Located in Control Relay Cabinets in EDG Rooms May Exceed Design Ambient Temp Rating.Caused by Proximity of Cabinets to Edg.Fuses Will Be Replaced + (07:57:05, 14 December 2024)
- 05000313/LER-1991-010-03, :on 911005,discovered That Offsite Power Source May Be Unable to Maintain Adequate Voltage to Safety Loads During Accident Conditions.Caused by Increased Offsite Grid Loading.Procedural Guidance Implemented + (07:57:07, 14 December 2024)
- HL-1916, Special Rept 1-91-008:on 911014,four Suppression Sys Flooding Valves in Fixed Water Suppression Sys Not Surveilled Once Per 18 Months.Caused by Less than Adequate Procedure.Valves Tested & Inspected Per Revised Procedures + (07:57:08, 14 December 2024)
- HL-1902, Forwards Results of Insp of IGSCC in Susceptible Welds, Performed During Current Refueling Outage,Per Generic Ltr 88-01 & Rev 2 to NUREG-0313.New crack-like Indications Noted in One 28 Category C Weld + (07:57:09, 14 December 2024)
- ML20085N344 + (07:57:09, 14 December 2024)
- 05000361/LER-1991-016-01, :on 911010,control Room Isolation Sys,Train B, Spurious Actuation Occurred.Caused by Momentary Instrument Failure of Train B Particulate/Iodine Channel.Filtering Circuit Added to Ac Input to Monitor Module + (07:57:11, 14 December 2024)
- ML20085N325 + (07:57:12, 14 December 2024)
- 05000482/LER-1991-019, :on 911011,broken Fuel Rod Discovered in Fuel Assembly F31 Located in Core Position L-9 During Fuel off-loading Operations.Caused by grid-to-rod Fretting.New Core Loading Design Pattern Developed + (07:57:14, 14 December 2024)
- ML20085N308 + (07:57:15, 14 December 2024)
- ML20085N315 + (07:57:15, 14 December 2024)
- ML20085N287 + (07:57:16, 14 December 2024)
- ML20085N291 + (07:57:16, 14 December 2024)
- TXX-9517, Forwards Individual Plant Exam of External Events for Severe Accident Vulnerabilities, Per GL 88-20,Suppl 4 + (07:57:17, 14 December 2024)
- ML20085N280 + (07:57:18, 14 December 2024)
- ML20085N281 + (07:57:18, 14 December 2024)
- HL-4872, Forwards Addl Info to Support Response Time Testing TS Rev Request, ,based on 950606 Telcon W/Nrc + (07:57:19, 14 December 2024)
- ML20085N276 + (07:57:19, 14 December 2024)
- ML20085N259 + (07:57:21, 14 December 2024)
- ML20085N263 + (07:57:21, 14 December 2024)
- ML20085N256 + (07:57:22, 14 December 2024)
- 05000301/LER-1991-002-01, :on 911014,insp of SG Hot Leg Revealed Degraded Tubes.Results of 800 Psig Leak Test Were Satisfactory.All Tubes in Both a & B SGs Plugged + (07:57:23, 14 December 2024)
- ML20085N247 + (07:57:24, 14 December 2024)
- 05000318/LER-1995-005, :on 950524,facility Manually Tripped Due Ground Fault in Mcc.Area Around MCC 208 Quarantined,Action Taken to Strengthen Expectations & Work Practices & Maint Orders Issued to Inspect,Repair,Clean & Test MCC 208 + (07:57:26, 14 December 2024)
- ML20085N223 + (07:57:27, 14 December 2024)
- ML20085N220 + (07:57:28, 14 December 2024)
- ML20085N215 + (07:57:29, 14 December 2024)
- ML20085N219 + (07:57:29, 14 December 2024)
- ML20085N213 + (07:57:30, 14 December 2024)
- ML20085N212 + (07:57:31, 14 December 2024)
- ML20085N197 + (07:57:32, 14 December 2024)
- 05000265/LER-1991-012-05, :on 911007,spurious Actuation of Electromagnetic Relief Valve Occurred & Pilot Valve for Relief Valve Found Stuck Open.Caused by Binding in Pilot Valve.Valve Internals Replaced + (07:57:34, 14 December 2024)
- ML20085N194 + (07:57:35, 14 December 2024)
- 05000301/LER-1991-003-01, :on 911010,containment Hatch Temporary Third Door Blocked Open During Fuel Movement Due to Personnel Error.Outer Third Door Shut & Refueling Procedure Revised.W/ + (07:57:36, 14 December 2024)