- ML20100F877 + (10:54:35, 13 December 2024)
- ML20100F872 + (10:54:38, 13 December 2024)
- ML20100F869 + (10:54:39, 13 December 2024)
- 05000364/LER-1985-007, :on 850301,while Reviewing Limiting Condition for Operation Forms During Shift Turnover,Fire Watch Requirements for Inoperable Fire Barrier Incorrectly Determined.Caused by Personnel Error + (10:54:40, 13 December 2024)
- ML20100F856 + (10:54:43, 13 December 2024)
- ML20100F854 + (10:54:44, 13 December 2024)
- ML20100F853 + (10:54:44, 13 December 2024)
- ML20100F842 + (10:54:46, 13 December 2024)
- ML20100F840 + (10:54:47, 13 December 2024)
- ML20100F831 + (10:54:48, 13 December 2024)
- ML20100F836 + (10:54:48, 13 December 2024)
- RBG-19522, Final Deficiency Rept DR-167 Re Wiring Discrepancies in HPCS Diesel Generator Control Panel.Condition Not Reportable Under 10CFR50.55(e).Request LD1-1246 Issued to Correct Identified Discrepancies + (10:54:49, 13 December 2024)
- ML20100F826 + (10:54:50, 13 December 2024)
- ML20100F825 + (10:54:51, 13 December 2024)
- ML20100F810 + (10:54:52, 13 December 2024)
- ML20100F809 + (10:54:53, 13 December 2024)
- 05000483/LER-1985-010, :on 850331,ESFs Actuated Due to Low Steam Generator Levels.Caused by nonsafety-related 120-volt Ac Instrument Bus Deenergized Due to Faulty Transformers. Transformers Replaced + (10:54:55, 13 December 2024)
- RBG-19496, Interim Deficiency Rept DR-206 Re Lubricant in Two Fuel Pool Cooling Pumps & Motors.Next Rept Will Be Provided by 850124 + (10:54:57, 13 December 2024)
- ML20100F806 + (10:54:57, 13 December 2024)
- ML20100F775 + (10:54:59, 13 December 2024)
- ML20100F769 + (10:55:00, 13 December 2024)
- ML20100F758 + (10:55:01, 13 December 2024)
- ML20100F755 + (10:55:01, 13 December 2024)
- LIC-96-0016, Monthly Operating Rept for Jan 1996 for Fort Calhoun Station Unit 1 + (10:55:02, 13 December 2024)
- ML20100F733 + (10:55:02, 13 December 2024)
- ST-HL-AE-1150, Interim Deficiency Rept Re Trapeze Type Support Assemblies. Initially Reported on 841022.Pipe Support Designs Will Be Reviewed to Identify Number of Supports Subj to Deficiency. Personnel Given Addl Training.Next Rept by 850322 + (10:55:03, 13 December 2024)
- 05000315/LER-1985-007-01, :on 850222,controlled Shutdown Initiated. Caused by Inoperable Control Room Emergency Ventilation Sys. Analysis of Potential Radiological Consequences of Operation at Higher Flow Rates Performed.Room Balanced + (10:55:05, 13 December 2024)
- ML20100F724 + (10:55:09, 13 December 2024)
- ML20100F716 + (10:55:12, 13 December 2024)
- ML20100F714 + (10:55:12, 13 December 2024)
- 05000269/LER-1985-003-02, :on 850222,emergency Safeguard Features Actuation Sys Setpoint Adjusted to 1,600 Psig.Caused by B&W Reanalysis of Small Break LOCA Transients,Per NUREG-0737. Setpoint Changes Initiated + (10:55:14, 13 December 2024)
- ML20100F708 + (10:55:15, 13 December 2024)
- ML20100F705 + (10:55:16, 13 December 2024)
- RBG-19480, Interim Deficiency/Part 21 Rept Re Topaz Inverters Supplied by Ge.Initially Reported on 841019.Discussions W/Ge Currently Underway to Determine Appropriate Corrective Action.Next Rept Expected by 850122 + (10:55:17, 13 December 2024)
- 05000322/LER-1985-008, :on 850227,emergency Diesel Generator 103 Automatically Started.Caused by Technician Error Coincident W/Reset of Ground Alarm Relay Tripping During Surveillance Procedure + (10:55:19, 13 December 2024)
- 05000528/LER-1985-010, :on 850222,automatic Actuation of balance-of- Plant ESF Actuation Sys Occurred When Placing Train a Sequencer in Manual from Automatic Mode.Caused by Unique Circumstances Involving flip-flop U-14 + (10:55:21, 13 December 2024)
- ML20100F695 + (10:55:22, 13 December 2024)
- ML20100F693 + (10:55:23, 13 December 2024)
- ML20100F694 + (10:55:23, 13 December 2024)
- ML20100F691 + (10:55:24, 13 December 2024)
- 05000457/LER-1996-001-03, :on 960118,inadequate Control of Staged Roofing Matls Lead to Loss of Offsite Power Due to Loss of Both Unit 2 Station Auxiliary Transformers.Addressed Control of Staged Const Matls Onsite + (10:55:26, 13 December 2024)
- ML20100F683 + (10:55:27, 13 December 2024)
- RBG-19485, Final Deficiency Rept DR-256 Re Var & Watt Scales in Standby Diesel Generators Supplied by Tdi.Initially Reported on 841019.Existing 0-5000 Kw & 0-5000 Kvar Scales in 1EGS*PNL1A & 1EGS*PNL1B to Be Replaced + (10:55:28, 13 December 2024)
- ML20100F682 + (10:55:28, 13 December 2024)
- 05000289/LER-1984-004-03, :on 830602,discovered Tube A-134-74 Mistakenly Plugged in June 1983 While Tube A-135-72 Left Unplugged. Complete Photographic Reverification of All Plugged Tubes Performed + (10:55:30, 13 December 2024)
- 05000528/LER-1985-013, :on 850223,Train B Diesel Generator Started Inadvertently During Routine Surveillance Testing.Caused by Error in Surveillance Procedure for Testing Certain Subgroup Relay Contacts.Change Notice Issued + (10:55:32, 13 December 2024)
- ML20100F673 + (10:55:33, 13 December 2024)
- 05000289/LER-1984-004, Forwards Corrected LER 84-004-00 Re Misplugged Steam Generator Tubes.Rept Date Corrected & Licensee Contact Changed + (10:55:34, 13 December 2024)
- ML20100F664 + (10:55:34, 13 December 2024)
- 05000339/LER-1984-010-01, :on 841101,accumulator Isolation Valves a & B Inadvertently Opened When Breakers Energized.Caused by Solid Protection Sys Slave Relay in Deenergized State.Relay Actuated Into Correct Position + (10:55:36, 13 December 2024)
- ML20100F652 + (10:55:37, 13 December 2024)