- ML20128A612 + (20:06:11, 12 December 2024)
- ML20128A605 + (20:06:36, 12 December 2024)
- PNO-II-85-056, on 850517,reactor Tripped.Caused by Loss of Offsite Power Due to Fire Disabling 500-kV Line Near Util Substation.Unusual Event Declared.All Safety Sys Functioned Normally.Power Restored + (20:06:42, 12 December 2024)
- 05000275/LER-1985-017, :on 850523,maint Employee Permitted to Enter High Radiation Area W/O Positive Exposure Control W/Unit in Mode 1.Caused by Personnel Error.Technician Counseled & Will Be Disciplined + (20:06:48, 12 December 2024)
- ML20128A594 + (20:06:51, 12 December 2024)
- ML20128A590 + (20:06:52, 12 December 2024)
- 05000309/LER-1993-001, :on 921202,determined That,For Brief Period of Time,Both Trains of ECCS LPSI & Containment Spray Subsystems Inoperable.Caused by Erroneous Original TS License Submittal.Valve Stroke Test Frequency Changed + (20:06:57, 12 December 2024)
- ML20128A580 + (20:07:01, 12 December 2024)
- ML20128A578 + (20:07:04, 12 December 2024)
- 05000328/LER-1985-010-03, :on 850522,reactor Trip Received from RCS Over Power/Differential Temp Trip Function at 100% Power.Caused by Personnel Error.Temp Loops Tested.Data Collection Sheet Modified + (20:07:08, 12 December 2024)
- ML20128A574 + (20:07:12, 12 December 2024)
- ML20128A572 + (20:07:14, 12 December 2024)
- ML20128A569 + (20:07:17, 12 December 2024)
- ML20128A568 + (20:07:18, 12 December 2024)
- ML20128A567 + (20:07:20, 12 December 2024)
- ML20128A564 + (20:07:22, 12 December 2024)
- PLA-2477, Requests Registration as User of Model 0H-142 + (20:07:25, 12 December 2024)
- ML20128A561 + (20:07:26, 12 December 2024)
- ML20128A558 + (20:07:28, 12 December 2024)
- ML20128A557 + (20:07:31, 12 December 2024)
- IR 05000395/1992023 + (20:07:40, 12 December 2024)
- ML20128A549 + (20:07:41, 12 December 2024)
- ML20128A548 + (20:07:43, 12 December 2024)
- ML20128A547 + (20:07:44, 12 December 2024)
- ML20128A545 + (20:07:48, 12 December 2024)
- ML20128A544 + (20:07:50, 12 December 2024)
- ML20128A541 + (20:07:52, 12 December 2024)
- ML20128A540 + (20:07:54, 12 December 2024)
- ML20128A539 + (20:07:55, 12 December 2024)
- ML20128A537 + (20:07:57, 12 December 2024)
- ML20128A528 + (20:08:00, 12 December 2024)
- ML20128A524 + (20:08:02, 12 December 2024)
- ML20128A522 + (20:08:03, 12 December 2024)
- ML20128A521 + (20:08:05, 12 December 2024)
- ML20128A518 + (20:08:07, 12 December 2024)
- ML20128A512 + (20:08:11, 12 December 2024)
- IR 05000424/1992031 + (20:08:17, 12 December 2024)
- ML20128A507 + (20:08:19, 12 December 2024)
- 05000259/LER-1985-019-01, :on 850523,during Routine Flushing of Fire Protection Strainers,Low Pressure on High Pressure Fire Protection Sys Header Noted.Caused by Sys Isolation Header Valves Being Left Closed After Maint Repair + (20:08:23, 12 December 2024)
- ML20128A495 + (20:08:29, 12 December 2024)
- ML20128A494 + (20:08:30, 12 December 2024)
- ML20128A488 + (20:08:32, 12 December 2024)
- ML20128A486 + (20:08:34, 12 December 2024)
- ML20128A485 + (20:08:35, 12 December 2024)
- ML20128A482 + (20:08:36, 12 December 2024)
- ML20128A481 + (20:08:38, 12 December 2024)
- ML20128A479 + (20:08:39, 12 December 2024)
- ML20128A478 + (20:08:40, 12 December 2024)
- ML20128A475 + (20:08:41, 12 December 2024)
- ML20128A474 + (20:08:42, 12 December 2024)
- 05000335/LER-1985-005-03, :on 850523,control Rod Slipped,Creating Deviation Between Rod & Remainder of Group.Caused by Personnel Error.Procedure Will Be Revised to Clarify Tech Spec Requirement + (20:08:45, 12 December 2024)