Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000289/LER-1979-003-03, /03L-0 on 790217:during post-shutdown Operations, While Performing Emergency Sequence & Power Transfer Test, High Pressure Injection Pump MU-P-1C Tripped on Overload. Caused by Failed Lead Between Winding & Motor.Lead Repair + (07:02:55, 1 January 2025)
- 05000289/LER-1979-003, Forwards LER 79-003/03L-0 + (07:02:58, 1 January 2025)
- ML19322A270 + (07:02:59, 1 January 2025)
- ML19322A272 + (07:02:59, 1 January 2025)
- ML19322A268 + (07:03:01, 1 January 2025)
- ML19322A269 + (07:03:01, 1 January 2025)
- ML19322A267 + (07:03:03, 1 January 2025)
- ML19322A266 + (07:03:04, 1 January 2025)
- ML19322A265 + (07:03:05, 1 January 2025)
- ML19322A264 + (07:03:05, 1 January 2025)
- ML19322A263 + (07:03:06, 1 January 2025)
- ML19322A261 + (07:03:07, 1 January 2025)
- ML19322A262 + (07:03:07, 1 January 2025)
- ML19322A260 + (07:03:08, 1 January 2025)
- ML19322A259 + (07:03:10, 1 January 2025)
- ML19322A257 + (07:03:11, 1 January 2025)
- ML19322A256 + (07:03:11, 1 January 2025)
- ML19322A255 + (07:03:12, 1 January 2025)
- ML19322A254 + (07:03:12, 1 January 2025)
- ML19322A252 + (07:03:13, 1 January 2025)
- ML19322A249 + (07:03:14, 1 January 2025)
- 05000289/LER-1979-002-03, /03L-0 on 790112:when Actuation Signal Was Applied to Open Valve from Its mid-position DH-V-58,motor Breaker Tripped. Caused by Motor Brake Not Releasing. Brake Will Be Inspected by 790331 + (07:03:16, 1 January 2025)
- 05000289/LER-1979-002, Forwards LER 79-002/03L-0 + (07:03:18, 1 January 2025)
- ML19322A245 + (07:03:19, 1 January 2025)
- ML19322A243 + (07:03:20, 1 January 2025)
- ML19322A242 + (07:03:21, 1 January 2025)
- 05000289/LER-1979-001-03, /03L-0 on 790107:during Inservice Insp Test on Decay Heat River Water Pump 1A(DR-P1a),vibration Level Was within Required Action Range. Caused by Imbalance Due to Rag in Pump Section & Perturbed by Shaft Sleeve Wear + (07:03:23, 1 January 2025)
- 05000289/LER-1979-001, Forwards LER 79-001/03L-0 + (07:03:25, 1 January 2025)
- IR 05000289/1978019 + (07:03:34, 1 January 2025)
- ML19322A234 + (07:03:36, 1 January 2025)
- ML19322A233 + (07:03:37, 1 January 2025)
- ML19322A232 + (07:03:38, 1 January 2025)
- ML19322A230 + (07:03:39, 1 January 2025)
- 05000289/LER-1979-001-01, /01T-1 on 780106:informed by B&W That Difference Between Reactor Power as Indicated by out-of-core Instrumentation & as Calculated by Heat Balance May Exceed 4% of Full Power.Tech Spec Change Initiated + (07:03:41, 1 January 2025)
- ML19322A225 + (07:03:43, 1 January 2025)
- ML19322A224 + (07:03:44, 1 January 2025)
- ML19322A222 + (07:03:45, 1 January 2025)
- ML19322A219 + (07:03:46, 1 January 2025)
- ML19322A220 + (07:03:46, 1 January 2025)
- ML19322A218 + (07:03:47, 1 January 2025)
- ML19322A217 + (07:03:48, 1 January 2025)
- ML19322A215 + (07:03:49, 1 January 2025)
- ML19322A212 + (07:03:57, 1 January 2025)
- ML19322A211 + (07:03:58, 1 January 2025)
- ML19322A210 + (07:03:59, 1 January 2025)
- ML19322A209 + (07:04:00, 1 January 2025)
- IR 05000333/1978019 + (07:04:02, 1 January 2025)
- ML19322A206 + (07:04:03, 1 January 2025)
- ML19322A205 + (07:04:04, 1 January 2025)
- ML19322A204 + (07:04:06, 1 January 2025)
- ML19322A202 + (07:04:08, 1 January 2025)