Text

'

,

dwg# %

UNITE] STATES

d

NUCLEAR REGlJLATORY COMMISSION

h )P(

S

E

REGION I

D

Af

631 PARK AVENUE

,.

%

/

xiso or nussiA. PENNSYt.VANI A 19406

.....

Docket No. 50-289

7 DEC 1978

Metropolitan Edison Company

ATTN: Mr. J. G. Herbein

Vice President - Generation

P. O. Box 542

Reading, Pennsylvania 19603

Gentlemen:

Subject:

Inspection 78-19

This refers to the inspection conducted by Mr. D. Haverkamp of this

office on November 7-9 and 13-17,1978 at Three Mile Island Nuclear

Station, Unit 1. Middletown, Pennsylvania of activities authorized by

NRC License No. DPR-50 and to the discussions of our findings held by

Mr. Haverkamp with Mr. J. O'Hanlon of your staff at the conclusion of

the inspection.

Areas examined during this inspection are described in the Office of

Inspection and Enforcement Inspection Report which is enclosed with this

letter. Within these areas, the inspection consisted of selective

examinations of procedures and representative records, interviews with

personnel, measurements made by the inspector, and observations by the

inspector.

Based on the results of this inspection, it appears that one of your

activities was not conducted in full compliance with NRC requirements,

as set forth in the Notice of Violation, enclosed herewith as Appendix

A.

This item of noncompliance has been categorized into the levels as

described in our correspondence to you dated December 31, 1974. This

notice is sent to you pursuant to the provisions of Section 2.201 of the

NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office, within twenty (20)

days of your receipt of this notice, a written statement or explanation

in reply including:

(1) corrective steps which have been taken by you

and the results achieved; (2) corrective steps which will be taken to

avoid further items of noncompliance; and (3) the date when full compli-

ance will be achieved.

In accordance with Cection 2.790 of the NRC's " Rules of Practice," Part

2, Title 10, Code of Federal Regulations, a copy of this letter and the

enclosures will be placed in the NRC's Public Document Room.

If this

report contains any information that you (or your contractor) believe to

l

be proprietary, it is necessary that you make a written application

within 20 days to this office to withhold such information from public

190205md

.

.

'

.

Metropolitan Edison Company

2

7 DEC 1978

disclosure. Any such application must be accompanied by an affidavit

executed by the owner of the infurmation, which identifies the document

or part sought to be withheld, and which contains a statement of reasons

which addresses with specificity the items which will be considered by

the Comission as listed in subparagraph (b) (4) of Section 2.790.

The

information sought to be withheld shall be incorporated as far as possible

into a separate part of the affidavit.

If we do not hear from you in

this regard within the specified period, the report will be placed in

the Public Document Room.

Should you have any questions concerning this inspection, we will be

pleased to discuss them with you.

Sincerely,

f

-

~-

,

&d

J. Brunner, Chief

Reactor Operations and Nuclear

S'upport Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Office of Inspection and Enforcement Inspection

Report Number 50-289/78-19

cc w/encls:

E. G. Wallace, Licensing Manager

'

J. J. Barton, Project Manager

L. L. Lawyer, Manager - Generation Operations - Nuclear

G. P. Miller, Superintendent

J. L. Seelinger, Unit 1 Superintendent

I. R. Finfrock, Jr.

Mr. R. Conrad

G. F. Trowbridge, Esquise

Miss Mary V. Southard, thairman, Citizens for a Safe Environment

(WithoutReport)