Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- Information Notice 1991-35, Labeling Requirements for Transporting Multi-Hazard Radioactive Materials +
- ML17262A518 +
- ML17329A049 +
- ML17329A048 +
- ML17329A047 +
- ML17329A045 +
- ML17286B267 +
- ML20024H773 +
- ML17348A948 +
- ML17305B590 +
- ML17305B591 +
- ML18153C646 +
- ML20024H772 +
- ML20024H767 +
- ML20082G590 +
- ML20081H795 +
- ML20081G784 +
- ML20081G651 +
- ML20081G150 +
- ML20081G026 +
- ML20079C475 +
- ML20079B855 +
- ML20079B279 +
- ML20079B155 +
- ML20077G220 +
- ML20077E554 +
- ML20077E525 +
- ML20077E514 +
- ML20072K577 +
- ML20265B501 +
- ML20217Q682 +
- ML20079C071 +
- ELV-02867, Forwards Responses to NRC Re Station Blackout.Sys Required to Function During Station Blackout Include, Auxiliary Feedwater Sys,Main Steam sys,RCS,post-accident Monitoring Sys & Class 1E Dc Sys +
- 3F0691-01, Responds to NRC 910425 Request for Addl Info Re Inservice Insp Program Plan.Listed Relief Requests Re Class 2 Piping & Recertification of Level III Personnel by Exam on Triennial Basis Already Submitted +
- HL-1674, Special Rept 2-91-001:on 910320 & 0401,fire-rated Assemblies Inoperable for More than 14 Days Due to Reloading of Reactor Core & Planned Maint Activity,Respectively.Hourly Fire Watch Initiated & Set Room Walls Reinstalled +
- NLS9100366, Forwards Response to Questions on License Extension to 40 Yrs from OL Issuance,Per +
- NLS9100363, Application for Amend to License DPR-46,consisting of Proposed Change 96 to Tech Specs Re Verification of Equipment Operability by Exam of Appropriate Plant Records +
- DCL-91-152, Forwards Substitution Page for Change 3 to Rev 17 for Physical Security Plan,Submitted 901019.Encl Withheld (Ref 10CFR73.21) +
- ML20216B825 +
- ML20217Q666 +
- ML20198C282 +
- ML20127B977 +
- 05000334/LER-1991-013, :on 910510,pressurizer Code Safety Valve Lift Setting Discovered Less than Tech Spec Limits.Caused by Failure of Valves to Lift within Setpoint.Beaver Valley Test Procedure Criteria Reevaluated +
- 05000352/LER-1991-012, :on 910508,reactor Encl Overpressurized & Blowout Panel Opened Due to Failure of C Reactor Encl HVAC Supply Air Fan.Fan Power Supply Breaker Trip Coil Replaced & Satisfactorily Tested +
- 05000368/LER-1991-013-01, :on 910512,fire Watches Released from Inoperable Fire Barriers Prematurely.Caused by Inadequate Documentation Re Posting Requirements.Approval by Fire Protection Required Prior to Release in Future +
- 05000339/LER-1991-003-03, :on 910522,determined Surveillance Test on Four Safety Injection Sys Accumulator Nitrogen Sypply & Vent Valves Missed.Caused by Personnel Error.Affected Valves Successfully Tested +
- 05000298/LER-1991-005, :on 910511,unplanned Startup of Diesel Generator Number 2 Occurred Due to Equipment Deficiency During Plant Startup.Caused by Insufficent Action of Breaker.Breaker Shimmed & Reinstalled +
- 05000457/LER-1991-002-12, :on 910510,excessive Containment Purge Valve Leakage Discovered During Local Leakage Rate Testing Causing Reactor Shutdown.Caused by Seal Degradation.Resilient Matl Seals Replaced +
- 05000482/LER-1991-006, :on 910512,auxiliary Feedwater Actuation & Control Room Ventilation Isolation Occurred When Power Supply in ESF Actuation Sys Failed.Caused by Faulty 15 Volt Power Supply.Power Supply Replaced +
- PNO-II-91-027, on 910524,investigative Reporter Contacted Region II Re Levels of Contamination at Dawson Forest Wildlife Mgt Area.Low Levels of Co-60 Present on Property. Contaminated Areas Secured by Fencing +