- ML20210B049 +
- ST-HL-AE-3128, Special Rept:On 890523,24 & 0608,diesel Generator 13 Tripped During Testing Procedures.First Failure Caused by Increased Resistance Across Contacts of Unit Parallel Mode & Second & Third Failures by Inadequate Air Flow.Contacts Cleaned +
- ML20129F418 +
- A08881, Responds to NRC Re Violations Noted in Insp Rept 50-423/90-08.Corrective Action:Operators Directly Involved W/Event Removed from Licensed Duties & Counseled by Operations Manager on Causes of Event +
- ML23082A250 +
- ML21200A185 +
- ML23318A429 +
- 05000285/LER-1987-025-01, :on 870923,diesel Generator 2 Shutdown Due to High Coolant Temp.Caused by Presence of Residue Causing Pilot Valve That Directs Air Flow to Stick.Pilot Valve Inspected & Cleaned & Accumulator Drained +
- 05000249/LER-1986-008-08, :on 860618,Group II Primary Containment Isolation Received,Causing Isolation of Reactor Bldg Ventilation & Start of Standby Gas Treatment Sys.Caused by Personnel Error.Personnel Cautioned Re Maint +
- 05000395/LER-1988-001, :on 880204,three Perimeter Cameras Lost Due to Circuit Breaker Trip.Caused by Electricians Crimping Electrical Lead While Replacing Distribution Panel Cover. Security Procedures Implemented +
- 05000220/LER-1998-017-01, :on 980902,breach of Primary Containment Was Noted.Caused by Personnel Error in 1994.Immediately Upon Discovery,Asss Directed That CS Heat Exchanger Vent Valves Be Closed.With +
- 05000423/LER-1990-015, :on 900512,feedwater Isolation Occurred While Opening Msivs.Caused by MSIV 2 Opening Faster than Other Msivs,Resulting in Swell in Steam Generator 2.Steam Generator Level Restored to Normal +
- LIC-90-0167, Responds to NRC Re Violations & Deviations Noted in Insp Rept 50-285/89-40.Corrective Actions:Changes Made to Procedure AOP-17 & Procedure Generation Package Incorporated in Plant Procedures as Standing Order G-74 +
- ML20023A310 +
- ML20023A313 +
- NUREG-0227, Partial Draft of Nuclear Power Plant Operating Experience - 1978, Section 3.0, Plant Outages. Portions of NUREG-0483, NUREG-0366 & NUREG-0227 (Plant Operating Experience for 1977,1976 & 1974-75,respectively) Encl +
- 05000346/LER-1979-102-03, /03L-0:on 791022,during Feedwater Sys Monthly Surveillance Test,No Oil Level Visible in Oil Sight Glass on Inboard Bearing of Auxiliary Feedpump Turbine 1-1.Caused by Loose Sight Glass.Glass Tightened & Oil Replaced +
- 05000281/LER-1992-004-02, :on 920326,B Chiller Became Inoperable Due to Hand Operated Rocker Switch Inadvertently Being Placed in Off Position.Chiller Returned to Svc.Upgrade to Sys Will Include Installation of Two Chillers +
- 05000315/LER-1994-007, :on 940607,determined That Rod Position Indication Greater than 12 Steps from Demand Position Indication.Caused by Failure to Follow Procedure as Written. Correct Data Used to Determine Rod Position +
- IR 05000285/1987027 +
- ML20235P000 +
- ML20129J050 +
- ML20112C267 +
- 05000373/LER-1992-006-04, :on 920427,determined That Design Setpoint of 4 Kv Degraded Voltage Relays May Be Insufficient to Assure Proper Operation.On 920429,discovered That HPCS Pump Cooler Fan Voltage Lower than Required +