- 05000325/LER-2009-002 +
- 05000324/LER-2001-001 +
- ML17331A970 +
- ML17326A717 +
- ML17319A487 +
- ML060030080 +
- ML050950565 +
- ML20006F155 +
- ML040580690 +
- ML042080152 +
- ML022690051 +
- ML20134N787 +
- ML20128L204 +
- ML20151D460 +
- ML20204H430 +
- ML20236V897 +
- ML20217C426 +
- ML20211M608 +
- ML20197G272 +
- ML20135H316 +
- DCL-85-031, Startup Rept, for 831115-841031 +
- 05000440/LER-1997-010, :on 970911,loss of Electrical Power to Reactor Protection Sys Bus Occurred.Caused by Electrical Protective Assembly (EPA) Trip.Replaced EPA Logic Control Board & Associated Molded Case Circuit Breaker +
- 05000341/LER-1987-018, :on 870520,during Troubleshooting of Leakage Discovered in Drywell,Rwcu Inboard Isolation Valve Isolated Twice & Outboard Isolation Valve Once.Caused by Latent Heat Migration in Sys Piping.Valve Repacked +
- 05000414/LER-1987-018-01, :on 870505,defective Solid State Protection Sys Relay Identified.On 870506,reactor & Reactor Coolant Pump Motors Tripped.Problems Associated W/Valve & Yv/Rn Control Logic Being Investigated +
- ML20211F864 +
- 05000341/LER-1986-020, :on 860715,reactor Protection Sys,Nuclear Steam Supply Shutoff Sys & ECCS Logic Actuated During Inservice Leak Test.Caused by False Initiating Signal +
- 05000254/LER-1987-013-08, :on 870629,control Room HVAC Sys Isolation Occurred.Caused by Defective Functional Test Procedure or Probe Corrosion.Chlorine in Probe Vicinity Removed & Corroded Probe Replaced +
- 05000353/LER-1993-001-01, :on 930103,reactor Shut Down Automatically on High Pressure After Transient in EHC Sys Occurred Coincident w/balance-of-plant Battery Ground Alarm.Cause Indeterminate. Alarm Reset & Testing Currently Underway +
- 05000331/LER-1992-001, :on 920115,determined That Triple Low Level Trip Function May Not Be Functional at High Drywell Temps.On 910129,determined That HPCI & RCIC Trips May Not Function at High Drywell Temps.Level Instruments Calibr +
- 05000416/LER-1984-028, :on 840507,during Storm,Arcing Occurred Across Open Disconnect for 500 Kv Switchyard Breaker,Causing Loss of Power Which Resulted in Reactor Water Cleanup Reactor Isolation.Plant Shut Down +
- 05000373/LER-1994-004-01, :on 940105,CRPI Sys Failed Due to Card Failure. Notice of Enforcement Discretion Requested & Granted Not to Enforce Compliance W/Ts 3.1.3.7 for Period of 6 Addl H & on 940105,RPIS Declared Operable Following Repair & Testing +
- 05000277/LER-1990-030, :on 901024,control Room Emergency Ventilation Actuation Occurred Due to Inadvertent Opening of 480 Volt Breaker +
- IR 05000321/1993300 +
- 05000272/LER-1990-005-01, :on 900220,radiation Monitoring Sys Plant Vent Radioactive Noble Gas Monitor Channel Began Intermittently Spiking High Resulting in Containment Purge.Caused by Design /Equipment Problem.Equipment Replaced +
- 05000315/LER-1994-007, :on 940607,determined That Rod Position Indication Greater than 12 Steps from Demand Position Indication.Caused by Failure to Follow Procedure as Written. Correct Data Used to Determine Rod Position +
- ML16340E020 +
- ML17193A638 +
- 05000440/LER-2010-003, Regarding Loss of Control Rod Drive Header Pressure Results in Manual RPS Actuation +
- 05000324/LER-2009-002, (Bsep), Unit 1 Regarding Valid System Actuations Due to Loss of Power to Emergency Bus E2 +
- BVY-04-052, May 2004 Monthly Operating Report for Vermont Yankee +
- 05000333/LER-2003-001, Automatic Reactor Shutdown Due to Grid Instability Associated with the August 14, 2003 Transmission Grid Blackout and Related Plant Mode Change with the EDG Subsystem Inoperable +
- ML14184B070 +
- 05000219/LER-1986-034, :on 861229,reactor Manually Scrammed Due to Inability to Maintain Condenser Vacuum.Caused by Equipment Failure & Cooldown in Excess of Tech Spec Limit.Failed Relief Valve & Expansion Joint Replaced +