Message Page I of I Sienel, Beth From: Gill, Jeanne Sent: Tuesday, June 08, 2004 12:58 PM To:
'lereventsO inpo.org'; 'rbelval @velco.com'; 'gparker@ velco.com'; 'rivest@ gmpvt.com';
'martin @ gmpvt.com'; 'kvedar@ gmpvt.com'; 'dutton @ gmpvt.com'; 'brown @ gmpvt.com';
'william.sherman @ state.vt.us'; 'BOliveira @AmNucins.com'; 'barbaralewis @ platts.com';
'bamelan~cvps.com'; Kilburn, Bobbi; Thayer, Jay; Bronson, Kevin; Williams, Rob; Cosgrove, Brian; McElwee, David; Finn, Brian; Porter, Brad; Wanczyk, Robert; Sandstrum, Sally; Jefferson, Stan; Mannai, David; Wallin, Greg; Rondeau, Nancy; Skibniowsky, Steve; Sienel, Beth; Pelton, David Attached please find the Entergy Vermont Yankee Nuclear Power Station Monthly Statistical Report for May 2004.
If you have any questions please contact me.
Jeanne A. Gill Technical Support Controlled Document Specialist 802 451 3127 X3127 6/15/2004
'--Entergy Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
Vermont Yankee 322 Governor Hunt Rd.
RO. 8ox 157 Vernon, Vr 05354 Tel 802-257-7711 June 10, 2004 BVY-04-052 United States Nuclear Regulatory Commission AT'TN: Document Control Desk Washington, D.C. 20555
Reference:
(a) License No. DPR-28 (Docket No. 50-271)
In accordance with section 6.6.B of the Vermont Yankee Technical Specifications, submitted herewith is the Monthly Statistical Report for the Vermont Yankee Nuclear Power Station for the month of May. 2004.
Kevin H. Bronson General Manager, Plant Operations cc: USNRC Region I Administrator USNRC Resident Inspector USNRC Project Manager
VERMONT YANKEE NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 04-05 FOR THE MONTH OF MAY 2004
OPERATING DATA REPORT DOCKETNO.50-271 DATE 040610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 OPERATING STATUS
- 1. Unit Name:
Vermont Yankee
- 2. Reporting Period:
May
- 3. Licensed Thermal Power(MWt):1593
- 4. Nameplate Rating(Gross MWe): 540 I
- 5. Design Electrical Rating(Net MWe):
522
- 6. Maximum Dependable Capacity(Gross MWe):
535
- 7. Maximum Dependable Capacity(Net MWe):
510
- 8. If changes, occur in capacity ratings(Items Number 3 through 7) since last report, give reasons:
- 9. Power level to which restricted, if any(Net MWe):
N/A
- 10. Reasons for restrictions, if any:
N/A This Month Yr-to-Date Cumulative
- 11. Hours in Reporting Period 744.00 3647.00 278568.80
- 12. Number Of Hours Reactor was Critical 685.08 2944.50 234745.72
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 656.58 2912.40 231039.09
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thermal Energy Generated(MWH) 1004658.50 4588562.45 350561552.19
- 17. Gross Electrical Energy Generated(MWH) 334645.00 1570306.00 117802558.00
- 18. Net Electrical Energy Generated(IWH) 319916.00 1506570.00 112133081.00
- 19. Unit Service Factor 88.30 79.90 82.90
- 20. Unit Availability Factor 88.30 79.90 82.90
- 21. Unit Capacity Factor(Using MDC Net) 84.30 81.00 79.60
- 22. Unit Capacity Factor(Using DER Net) 82.40 79.10 78.00
- 23. Unit Forced Outage Rate 0.00 0.00 3.80
- 24. Shutdowns scheduled over next 6 months(Type, Date, and Duration of Each: N/A
- 25. If shut down at end of report period, estimated date of startup: N/A
- 26. Units In Test Status(prior to commercial operation): N/A Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION VYDPF 0411.01 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.F01.19F
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-271 UNIT Vermont Yankee DATE 040610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
MONTH May DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
0 0
0 64 227 365 457 508 512 511 513 512 512 512 508 509 17.
510 18.
507 19.
510 20.
507 21.
506 22.
503 23.
509 24.
511 25.
512 26.
512 27.
513 28.
513 29.
512 30.
513 31.
513 INSTRUCTIONS:
On this format, list the average daily unit power level in MWE-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
VYDPF 0411.02 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.FO1.18V
UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH MAY DOCKET NO 50-271 UNIT NAME Vermont Yankee DATE 040610 COMPLETED BY G.A. Wallin TELEPHONE (802)258-5414 1
2 3
4 5
Cause and Corrective Action to Prevent No.
Date Type Duration Reason Method of License System Component Recurrence.
Shutting Event Code Code (hours)
Down Report #
Reactor 04-02 040504 S
87.42 B,C 1
N/A RB CONROD Shutdown for RFO-24 refueling outage 1 F: Forced S: Scheduled 2 Reason:
A-Equipment Failure (Explain)
B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training and License Examination F-Administrative G-Operational Error (Explain)
H-(Explain) -
3 Method:
4 1 -
Manual 2 -
Manual Scram 3 -
Automatic Scram 4 -
Other (Explain)
Exhibit G-Instructions for Preparation of Data Entry Sheets for License Event Report (LER) File (NUREG 0161) 5 Exhibit I -
Same Source VYDPF 0411.03 DP 0411 Rev. 8 Page 1 of 1
DOCKET NO. 50-271 DATE 040610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 REPORT MONTH May
SUMMARY
OF OPERATING EXPERIENCES Highlights Vermont Yankee operated at 84.8% of rated thermal power for the month.
Gross electrical generation was 334,645 MWHe or 82.4% design electrical capacity.
Operating Summary The following is a chronological description of plant operations including other pertinent items of interest for the month:
At the beginning of the reporting period the plant was operating at 00.0%
of rated thermal power.
040503 At 1055 hours0.0122 days <br />0.293 hours <br />0.00174 weeks <br />4.014275e-4 months <br />, the reactor was critical.
(See Unit Shutdowns and Power Reductions) 040504 At 1331 hours0.0154 days <br />0.37 hours <br />0.0022 weeks <br />5.064455e-4 months <br />, the turbine-generator was phased to the grid.
040504 At 2113 hours0.0245 days <br />0.587 hours <br />0.00349 weeks <br />8.039965e-4 months <br />, the turbine-generator was removed from the grid.
040504 At 2307 hours0.0267 days <br />0.641 hours <br />0.00381 weeks <br />8.778135e-4 months <br />, the turbine-generator was phased to the grid and began a return to full power.
At the end of the reporting period the plant was operating at 99.9% of rated thermal power.
VYDPF 0411.04 (Sample)
DP 0411 Rev. 8 Page 1 of 1 RT No. 13.F01.18X