Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000461/LER-2001-001 +
- ML17095A276 +
- ML16056A560 +
- IR 05000361/2009002 +
- RS-17-099, Response to Request for Additional Information Regarding LaSalle County Station License Amendment Request for Extension of Type a and Type C Containment Leak Rate Test Intervals (PRA Branch) +
- NL-10-1623, Emergency Technical Specification Revision Request for TS 3.7.14, Engineered Safety Features (ESF) Room Cooler and Safety-Related Chiller System - Response to Requests for Additional Information +
- NL-09-0503, Response to Preliminary White Finding on 1B EDG Coupling Failure +
- ML051580507 +
- L-15-208, Provides Notification of Completion of Required Action by NRC Order EA-12-051, Reliable Spent Fuel Pool Instrumentation +
- L-03-201, November 2003 Monthly Operating Report for Beaver Valley Units 1 and 2 +
- ML051930487 +
- ML021330617 +
- ML20086M934 +
- ML20137A618 +
- ML20134G493 +
- ML20133F483 +
- ML20153E508 +
- ML20065T516 +
- IR 05000254/1987027 +
- ML20245K675 +
- IR 05000254/1987019 +
- ML20235L755 +
- ML20217M780 +
- IR 05000271/1987009 +
- ML20211F621 +
- 1CAN058606, Monthly Operating Rept for Apr 1986 +
- 05000267/LER-1989-011, :on 890623,discovered That Reheat Steam Attemperation Flow Not Accounted for in Secondary Heat Balance Calculation of Reactor Power.Caused by Inadequate Procedures.Procedure Changes Implemented +
- 05000352/LER-1987-019, :on 870525,during Surveillance Test on Reactor Water Level Transmitter,Transmitter Vented Before Being Isolated Causing Pressure Oscillations.Caused by Personnel Error.Low Level Water Signal Reset +
- 05000313/LER-1986-004, :on 860408,reactor Tripped on High RCS Pressure from 82% Power Following Secondary Sys Transient Due to Turbine Electrohydraulic Control Sys Malfunction. Caused by Lightning Strike Due to Grounding +
- 05000254/LER-1987-018, :on 870913,recirculation Motor Generator 1B Failed to Trip.Caused by Burnt Out Trip Coil.Breaker Sent to GE Facility for Testing,Various Components Replaced & Breaker Reinstalled +
- 05000413/LER-1985-041, :on 850613,main Feedwater Pump Trip Resulted in Manual Reactor Trip.Caused by Pump Recirculation Valve Not Capable of Modulating Quickly During Flow Reduction.Design Deficiency Corrected +
- 05000352/LER-1996-016, :on 960725,core Thermal Power Exceeded Licensed Power Limit During Power Transient.Caused by Defective EHC Sys Component & Reactor Scram.Defective Primary Frequency/ Voltage Converter Replaced & Calibration Performed +
- 05000499/LER-1992-006, :on 920522,component Cooling Water Outlet Valve from RHR HX 2C Opened & Header Pressure Decreased & Pump 2A Automatically Started.Possibly Caused by Loss of Power to Solenoid Valve.Visual Insp of Valve Performed +
- 05000499/LER-1995-002-01, :on 950131,pressurizer Level Channel LT-0467 Considered Inoperable Due to Use of Incorrect Calibr Correction factor.Up-to-date Controlled Scaling Document Has Been Provided for Affected Pressurizer Level Transmitter +
- IR 05000412/1981003 +
- ST-HL-AE-3392, Special Rept:On 900202,discovered That Overspeed Fuel Shutoff & Governor Lever Valve Tripped.Caused by Operator Leaving Valve in Tripped Position While Performing Maint Activity on 900201.Valve Reset & Tested +
- IR 05000317/1989023 +
- 05000499/LER-1989-025, :on 891006,channel in power-range Nuclear Instrumentation Improperly Calibr,Rendering Channel Inoperable.Caused by Inadequate Technician Training.Maint Qualification Program Developed +
- 05000334/LER-1980-026-03, /03L-0:on 800422,pump Being Used to Start Liquid Waste Discharge Observed to Have Higher than Normal Flow. Caused by Leaking Effluent Valves.Corrective Actions Scheduled to Be Completed as Soon as Possible +
- NUREG-0227, Partial Draft of Nuclear Power Plant Operating Experience - 1978, Section 3.0, Plant Outages. Portions of NUREG-0483, NUREG-0366 & NUREG-0227 (Plant Operating Experience for 1977,1976 & 1974-75,respectively) Encl +
- 05000281/LER-1988-014-02, :on 880528,RCS PORV PCV-2455C Cycled Open & Closed,Simultaneous W/Rcs Venting & Filling.Caused by Failure to Revise RCS Venting Procedure.Operating Procedures Revised +
- 05000260/LER-1993-005-01, :on 930520,ESF Actuation Occurred Due to Lifted Lead on MSIV Solenoid Circuit.Caused by Personnel Error. Plant Mods Training Handbook Will Be Revised +
- 05000397/LER-1994-006, :on 940330,discovered Broken HPCS-B1-DG 3 Battery Flag Terminal Weld.Caused by Poor Equipment Design. Damaged Battery Cell Replaced +
- L-15-337, Completion of Required Action by NRC Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events and NRC Order EA-12-051, Reliable Spent Fuel Pool +
- 05000499/LER-2015-001, Regarding Technical Specification Action Statement Time Exceeded Due to Turbine-Driven Auxiliary Feedwater Pump Test Failure Not Recognized +
- 05000334/LER-2013-001, Regarding Manual Start of a Motor Driven Auxiliary Feedwater Pump +
- 05000454/LER-2012-001, Regarding Unit 2 Loss of Normal Offsite Power and Reactor Trip and Unit 1 Loss of Normal Offsite Power Due to Failure of System Auxiliary Transformer Inverted Insulators +
- ML19190A176 +
- ML033510593 +
- 05000293/LER-2003-001, Re Manual Scram & Completion of a Required Shutdown Due to Recirculation Motor-Generator Trip & Runback +