- ML17328A321 +
- ML19340F000 +
- ML20043F408 +
- ML20055F673 +
- NL-03-144, August 2003 Monthly Operating Report for Indian Point, Unit 3 +
- ML20059F926 +
- ML20070Q770 +
- ML20070N148 +
- ML20086G160 +
- ML20117E085 +
- ML20137X746 +
- ML20196B688 +
- ML20066H791 +
- 05000352/LER-1987-059, :on 871023,reactor Encl Isolated on Low Differential Pressure During Application of Blocking Permit. Caused by Failed Check Valve on Instrument Air Compressor/ Dryer Train A.Failed Valve Replaced +
- 05000413/LER-1998-003-01, :on 980218,omission in Retest Manual Leads to Failure to Perform Required Retest Prior to Restoring Ci Valves to Svc.Retest Manual Will Be Updated to Reflect Specific TS Requirements for Ci Valves +
- 05000213/LER-1996-005, :on 960301,spent Fuel Cooling Was Shut Down Due to Discovery of Loose Parts.Caused by Inadequate Design. Piping from Both Sent Fuel Pool Cooling Pumps to Plate Exchanger Were Inspected for Loose Parts w/bore-a-scope +
- 05000334/LER-1987-009, :on 870428,hi & hi-hi Alarm Received on Auxiliary Bldg Train B Ventilation Radiation Monitor RM-VS-102B.Caused by Inadequate Sampling Procedures & Inexperienced Chemist.Procedures Revised +
- ML20203J701 +
- 05000324/LER-1988-015, :on 880426,limiting Conditions of Tech Specs 3.5.3.2,3.6.1.1,3.6.1.2 & 3.6.1.3 Not Met While Performing Startup Testing to Meet Tech Specs.Caused by Not Recognizing Mode Change.Standing Instruction Issued +
- 05000338/LER-1998-004-01, :on 980902,motor Operated Valve Surveillance Was Missed.Caused by Personnel Error.Station Entered 24 H Action of TS 4.0.3 & Station Deviation Rept Was Initiated to Document Condition.With +
- 05000373/LER-1986-001-03, :on 860110,control Room HVAC Sys Ammonia Detector Tripped,Causing ESF Actuation.Caused by Master Fault Due to Misaligned Gate Assembly or Dirty Photo Cell. Detector Reset & Mechanism & Optics Cleaned +
- 05000277/LER-1985-027-02, :on 851226,feedwater Flow Transient Occurred, Causing Low Reactor Water Level Scram & Group II & III Isolations.Caused by Reduction in Reactor Water Level When Reactor Feed Pump a Tripped.Damage Repaired +
- 05000213/LER-1996-024, :on 960901,B RHR Pump Was Found Inoperable in Mode 5.Caused by Original Mfg Defects Along W/Marginal Pump Design.Replaced Pump Rotating Element +
- 05000336/LER-1991-009-01, :on 910821,DG Exhibited Erratic Load Control, Resulting in Erratic Load Swings on DG 12 U.Caused by Intermittent Failure of Woodward Governor EG-A Control Unit. Unit Replaced & Full Test Program Conducted +
- 05000261/LER-1985-011, :on 850318,unit Received Reactor Trip & Safety Injection from Steam Line Differential Pressure Signal A. Caused by Ground Which Tripped Bus IB-9 Due to Leak on Blowdown Valve.Valve Repaired +
- 05000272/LER-1984-027, :on 841118,svc Water Leaks Discovered on Containment Fan Coil Units 14 & 11.Caused by External Surface Corrosion of Piping.Vent Lines,Flanges,Valves & Piping Replaced +
- 05000254/LER-1990-025, :on 901206,ESF Group II Isolation Occurred Due to Spurious Signal from Low Level Transmitter Lt 1-263-58A. Caused by Formation of Air Pocket in Transmitter Ref Leg. Procedures for Draining Vessel Enhanced +
- ML20138A663 +
- 05000255/LER-1991-009, :on 910519,qualified Core Exit Thermocouple Occurred & Unable to Be Repaired While Plant Is at Power. Caused by Failure of Instrument.Corrective Action Document Initiated to Document Event +
- 05000269/LER-2011-002, For Oconee Nuclear Station, Regarding Completion of a Shutdown Required by Technical Specifications for an Inoperable Containment Isolation Valve +
- ML20197H626 +
- 05000336/LER-1991-009, :on 910821,both EDGs Declared Inoperable.Caused by Load Swings Due to Oxidation Buildup on Relay Contacts. Governor Controls Sys on 12U DG & 13U DG Updated W/New Electronic Governor Actuator Controls +