Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20247L453 + (ML20247L453)
- ML20247L454 + (ML20247L454)
- ML20247L455 + (ML20247L455)
- ML20247L456 + (ML20247L456)
- ML20247L457 + (ML20247L457)
- ML20247L459 + (ML20247L459)
- ML20247L460 + (ML20247L460)
- ML20247L461 + (ML20247L461)
- ML20247L463 + (ML20247L463)
- ML20247L464 + (ML20247L464)
- 05000302/LER-1989-021, :on 890614,during Surveillance Test,Reactor Protection Sys Actuation Received.Cause Unknown.Monitoring Program Instituted to Look at Switch After Any Reactor Protection Sys Actuation + (ML20247L465)
- ML20247L467 + (ML20247L467)
- ML20247L469 + (ML20247L469)
- ML20247L472 + (ML20247L472)
- ML20247L473 + (ML20247L473)
- ML20247L476 + (ML20247L476)
- 05000482/LER-1989-012, :on 890626,control Room Ventilation Isolation Signal Initiated When Control Room Air Intake Radiation Monitor GKRE-04 Experienced Loss of Power.Caused by Blown Fuse.Fuse Replaced + (ML20247L477)
- ML20247L478 + (ML20247L478)
- ML20247L479 + (ML20247L479)
- ML20247L480 + (ML20247L480)
- PY-CEI-NRR-1042, Forwards LERs 89-004-01 & 89-022-00 for Plant + (ML20247L481)
- ML20247L482 + (ML20247L482)
- AECM-89-0070, Advises That Listed Property Insurance Coverage Will Be in Effect on 890401.Certificates of Coverage from Maelu & Nelia Encl + (ML20247L483)
- IR 05000006/1989002 + (ML20247L486)
- ML20247L488 + (ML20247L488)
- IR 05000192/1989003 + (ML20247L490)
- ML20247L491 + (ML20247L491)
- ML20247L492 + (ML20247L492)
- 05000285/LER-1989-011, :on 890418,hourly Fire Watch Patrol at Door 1025-2 Not Performed & Penetration Seal Not Restored to Operable Status within 7 Days.Caused by Use of Uncontrolled Working List.Security Bulletin Issued + (ML20247L494)
- 05000346/LER-1989-010, :on 890626,cooling Sys Compressor Would Not Start.Investigation Concluded That Pressure Switch Probably Tripped on 890612 When Sys Was Operated.Caused by Tripped Refrigerant Pressure Switch.Switch Reset + (ML20247L495)
- ML20247L498 + (ML20247L498)
- ML20247L500 + (ML20247L500)
- ML20247L502 + (ML20247L502)
- ML20247L503 + (ML20247L503)
- ML20247L504 + (ML20247L504)
- ML20247L506 + (ML20247L506)
- ML20247L507 + (ML20247L507)
- ML20247L508 + (ML20247L508)
- ML20247L510 + (ML20247L510)
- 05000298/LER-1989-014, :on 890424 & 26,unplanned Actuation of Group 6 Isolation Occurred.Caused by Loose Terminal Board Connection.Loose Terminal Board Connection Retightened + (ML20247L511)
- 05000440/LER-1989-022, :on 890627,deficient Surveillance Instruction Resulted in Scram Discharge Vol High Level Instrument Outside Tech Spec Allowable Values.Caused by Procedural Deficiency.Surveillance Instructions Revised + (ML20247L512)
- ML20247L513 + (ML20247L513)
- ML20247L514 + (ML20247L514)
- ML20247L515 + (ML20247L515)
- ML20247L517 + (ML20247L517)
- ML20247L518 + (ML20247L518)
- ML20247L521 + (ML20247L521)
- ML20247L522 + (ML20247L522)
- ML20247L523 + (ML20247L523)
- ML20247L524 + (ML20247L524)
- ML20247L525 + (ML20247L525)